Sale!

MCR-UI-UI-NC Configurable 3-way isolating amplifier Phoenix

MCR-UI-UI-NC Configurable 3-way isolating amplifier Phoenix

Manufacturers :Phoenix
Model(s)  :MCR-UI-UI-NC
Additional Information :Configurable 3-way isolating amplifier
Estimated Shipping Size
Dimensions: 263 × 58 × 28mm
Weight:.4.3 kg
Country of Origin: United States of America

 

Categories: , SKU: MCR-UI-UI-NC

Description

Overview


Essential details:MCR-UI-UI-NC Configurable 3-way isolating amplifier Phoenix

MACX MCR-UI-UI 3-way isolating amplifiers are used to electrically isolate and convert standard analog signals. 3-way isolation prevents interference between different sensor circuits and thus improves the quality of the measuring circuit.
DIP switches can be used to reconfigure the inputs and outputs of the isolating amplifier, enabling more than 1600 signal conversions to be set.
When ordering preconfigured modules, specify the desired input and output signal combination (see order key). If the information is incorrect or unavailable, the devices will be supplied with the standard configuration (0 … 10 V input signal, 0 … 20 mA output signal).
Features
– 3-way electrical isolation
– More than 1600 signal combinations can be set using DIP switches (no software required)
– Up to SIL 2 according to EN 61508 for the live zero output
– Installation in zone 2 permitted
– Wide-range power supply including tolerance of 19.2 … 253 V AC/DC
– Step response (10 … 90%) of 35 µs (at 10 kHz), 11 ms (at 30 Hz)
– With screw or spring-cage connection
– Active and passive output

MCR-UI-UI-NC

• Mount the module on a 35 mm DIN rail according to EN 60715.
• Install the module in suitable housing to meet the requirements for the protection class.
• During startup, check that the MACX MCR-UI-UI-UP(-SP)(-NC) is operating and wired correctly, especially with regard to the wiring and labeling.
7.5 Connecting the cables
• Screw terminal blocks for MACX MCR-UI-UI-UP(-NC); fit litz wires with ferrules.
Permissible cable cross-section: 0.2 … 2.5 mm²
• Spring-cage terminal blocks for
MACX MCR-UI-UI-UP-SP(-NC);
litz wires can be fitted with ferrules. Permissible cable cross-section: 0.2 … 1.5 mm²
• Install intrinsically safe and non-intrinsically safe cables separately.
• Screw connection:
– Insert the wire with ferrule into the corresponding connection terminal block.
– Use a screwdriver to tighten the screw in the opening above the connection terminal block.
• Spring-cage connection:
– Insert a screwdriver into the opening above the connection terminal block.
– Insert the wire with or without ferrule into the corresponding connection terminal block.

lf you need to inquire or purchase ,please send the product models to my email or call medirectly .

Sales Manager: Manager He
E-mail number: sales@xiongbagk.cn
skype/ wechat: +86-18059884797
Mobile phone/wechat: +86-18059884797
QQ:3095989363

Same day shipment of 1000 parts

My company under the Sales and Marketing Department, technical engineering Department, after-sales service department, the department of comprehensive management. We can help your business with good service.

1. Sales Department 24/7 service. Handles your requests for any PLC DCS products in a timely manner with patience and professionalism.

2. The engineering department ensures that the products have no quality problems. All products will be inspected before shipping.

3. The financial department checks the payment and refund in time.

4. The warehouse department will carefully check the list of goods, carefully pack them, and deliver the goods in time.