Sale!

330180-51-CN 3300 XL Proximitor® Sensor Bently Nevada

330180-51-CN 3300 XL Proximitor® Sensor Bently Nevada

Manufacturers :Bently Nevada
Model(s)  :330180-51-CN
Additional Information :3300 XL Proximitor® Sensor
Estimated Shipping Size
Dimensions: 263 × 138 × 88mm
Weight:.2.35 kg
Country of Origin: United States of America

 

Categories: , SKU: 330180-51-CN

Description

Overview


Essential details:330180-51-CN 3300 XL Proximitor® Sensor Bently Nevada

  • Manufacturer : Bently Nevada
  • Product No. : 330180-51-CN
  • Product type : 3300 XL Proximitor® Sensor
  • Made in U.S.A
  • Can add-on Certificate Of Origin (COO)
  • Total Length and Mounting Option : 51 = 5.0 metre (16.4 feet) system length, DIN mount
  • Agency Approval Option : CN = Approvals country specific  (CN Approvals Option Quick Reference Guide and Field Notification Letter are in the download section)
  • Proximitor® Sensor Input : Accepts one noncontacting 3300- series 5 mm, 3300 8 mm or 3300 XL 8 mm Proximity Probe and Extension Cable.
  • Proximitor® Sensor Material : A308 aluminum
  • Operating Temperature : -51 °C to +100 °C (-60 °F to +212 °F)
  • Storage Temperature : -51 °C to +105 °C (-60 °F to +221 °F)
  • Weight : 0.7 Kg
  • Shipping Weight : 2 Kg

330180-51-CN

Superiority products 330180-51-CN 3300 XL Proximitor® Sensor Bently Nevada

• High Level Analog Input /HART Input Module (16pt) – The High Level Analog Input Module supports both high level analog and HART inputs. Analog inputs are typically 4-20mA DC for both traditional and HART devices. HART data can be used for status and configuration. HART data, such as the secondary and tertiary variables, can also be used as process control variables. Two versions are available.
• High Level Analog Input w/o HART (16pt) – The High Level Analog Input Module supports high level analog inputs Analog inputs are typically 4-20mA DC for traditional devices.
• Analog Output/HART Output Module (16pt) – The Analog Output Module supports both standard 4-20mA DC outputs and HART transmitter outputs. Two versions are available.
• Analog Output w/o HART (16pt) – The Analog Output Module supports standard 4-20mA DC outputs.
• Digital Input 24 VDC (32pt) – Digital input sensing for 24V signals. Two versions are available.
• Digital Input High Voltage (32pt) – Digital input sensing for 110 VAC, 220 VAC, 125VDC.
• Digital Output 24 VDC (32 pt) – Current sourcing digital outputs. Outputs are electronically short-circuit protected. Two versions are available.
• Relay Digital Output (32 pt) – Digital output with NO or NC dry contacts. Can be used for low power or high power applications.
• Temperature Multiplexer (64 pt) – Provides thermocouple (TC) and resistance temperature device (RTD) inputs. The Multiplexer supports up to four, field proven PMIO FTAs.
• Temperature Multiplexer (64 pt) – Provides thermocouple (TC) and resistance temperature device (RTD) inputs. The Multiplexer supports up to four, field proven PMIO FTAs
• Pulse Input (8pt) – Provide linear counting, PV generation, and Quaduature Input for Custody Transfer
• Universal Input Output (32 pt) – Supports 32 channels of user configurable IO. Choices available – analog input, analog output, digital input, and digital output.