Description
Overview
Essential details:SST-SR4-CLX-RLL For Rockwell ControlLogix Brad® SST™ Communication module Molex
The SST™ communication module for Rockwell ControlLogix systems is designed to include plant automation, process control and complex machines
The best choice within various applications.
Each SR4 module has 4x serial communication channels that can be isolated and disconnected from industrial equipment such as Modbus master or slave stations A lot of data is exchanged on the edge.
Save configuration and diagnostic time by using control board software that connects remotely via EtherNet/IP or RSLinx. Each module Delivered with its custom Add-On Profile (AOP) for easy integration in RSLogix 5000 software. The module and Input/output data transfer between ControlLogix cpus (processors) supports two modes: “Direct mode”, without writing any data Ladder logic, can share up to 248 input words + 248 output words, or “paging mode”, can share up to 32,000 input/output words. CLXT modules can withstand high temperatures and operate in harsh, corrosive environments to meet customer application requirements.
Superiority products SST-SR4-CLX-RLL For Rockwell ControlLogix Brad® SST™ Communication module Molex
Complete integration into Rockwell Integrated
Architecture Builder™ and ProsposalWorks™
A single module supports more communications than its competitors
Tao sum protocol
Direct input/output mapping; No need to write ladder logic
Input/output data is refreshed per PLC cycle, per channel
Up to 255 read/write loop accesses
New user-friendly configuration tool with visual loop feature
Screen
The software package comes with advanced visual diagnostic tools
Share with Rockwell CPU using a single module
32000 word input/output processing data
Separate electrically insulated serial channel
Supports variable input/output and status data size
Each port can be set up as a Modbus master or slave
CLXT modules feature a wider temperature range and conformal coating,
Heavy component
Quickly configure systems and create bills of materials
Reduces the number of modules required; Save backplane space and lower
System cost
Reduces programming time by more than 90%; User test demo
Time can be shortened from days to hours
Can improve performance; Accelerate system response and increase productivity
Simplify user training and debugging; Easy to configure
Easy troubleshooting
There is no need to use multiple cards in large applications
Improves reliability; Prevent noise transmission to other channels
Enables redundant applications using ControlNet
Provides great flexibility and can reduce system costs
Available with Rockwell ControlLogix XT PLC
Designed for use in harsh, corrosive environments