Description
Overview
Essential details:AAI143-S50 Analog I/O Modules YOKOGAWA
Products Description
This document describes about hardware specifications of Analog I/O Modules (for FIO) to be installed in the ESB bus node units (ANB10S and ANB10D), Optical ESB bus node units (ANB11S and ANB11D), ER bus node units (ANR10S and ANR10D) (*1), and field control units (for FIO) (AFV30S, AFV30D, AFV40S, AFV40D, AFV10S, AFV10D, AFF50S, and AFF50D).
These analog I/O modules function as signal converters; by inputting field analog signals into these modules, it converts them to internal data for field control stations (FCS), or the FCS’s internal data to analog signals for outputs.
*1: Field control units (AFV30 and AFV40) do not support ER bus node unit (ANR10).
In general, the power module is inserted in the first slot with the number 0, the 0,PLC is inserted in the second slot, and various types of I/O modules are inserted in the remaining slots. Printed circuit boards with connectors are installed on the back of the I/O module guide rail, which can connect the slots inserted into the I/O module, and the upper and lower sides of the slots can make the inserted modules line up in a straight line. The guide rail with I/O module and processor is called local I/O guide rail; The guide rail with I/O module, power supply and remote I/O communication card and installed far away from the local I/O guide rail is called remote I/O guide rail. The number of remote I/O rails depends on the number of variables that can be controlled by different processors. The communication between the remote I/O rail and the processor can be realized in many ways, including coaxial cable, biaxial cable, shielded twisted pair, etc. If the distance is far away and noise interference needs to be suppressed, optical fiber communication can be used.
FLEX digital I/O modules can be divided into three types according to their functions: output with protection, electronic safety, self-diagnosis and isolation.
(1) Protected output type: with electronic protection, it can cut off the output in case of short circuit, overload or overheating, and automatically recover when the output fault is eliminated. No fault status information is provided to the processor, and the end of the module model is P.
(2) With electronic safety: it can disconnect the output when a fault occurs, and reset the “safety” by operating buttons, software or input. The fault status information is provided to the processor, and the end of the module model is EP.
(3) With self-diagnosis: it can detect, indicate and report the following faults to the processor: the field input or output equipment is open or the wiring is open; Field device output short circuit; Input or output wiring is short-circuited; Reverse polarity of user power supply wiring. The end of the module model is d.
(4) Isolated type: the internal I/O channels are isolated from each other, and the end of the module model is 1.
Why Choose Us AAI143-S50 Analog I/O Modules YOKOGAWA
We are a professional service provider in the field of industrial automation components. We mainly provide PLC module, DCS card, ESD system card, vibration monitoring system card, turbine control system module, gas generator components, we have established a close cooperative relationship with many PLC and DCS product maintenance service providers. The company has established an e-commerce operation model, which reduces the intermediate links for consumers and provides consumers with high-quality products and satisfactory services. The company has a complete logistics supply system. We can buy directly from abroad and supply equipment and spare parts from different countries and manufacturers to solve your problem.
Packing & Shipping
Package Type: New and original factory separately sealed inner box
Delivery time: Prepare delivery inventory;
The goods will be packed according to the international standard.
1. We will deliver the goods within 3 working days after payment.
2. The new and original factory seal the inner box separately
3. We can send it to you by DHL/TNT/UPS/EMS/ fedex.
Please contact us directly and we will deliver the goods according to your requirements. Best quality assurance
4. We promise that all goods we supply are 100% new and original
5. One year warranty (after delivery date).
Payment method: We accept telegraphic transfer
Superiority products AAI143-S50 Analog I/O Modules YOKOGAWA
Yokogawa | Woodward | Schneider | TRICONEX |
Yokogawa PW481-10 | Woodward 8440-2050 | 140CPU67060 | TRICONEX 4119 |
Yokogawa PW482-50 | Woodward 8440-2116 | 140CRA31200 | TRICONEX 4200 |
Yokogawa SAI143-H33/PRP | Woodward 8440-2252 | 140ACO13000 | TRICONEX 3721 |
Yokogawa SAI143-S03 | Woodward 8440-2251 | 140DDI35300 | TRICONEX 4351B |
Yokogawa SAI533-H33 | Woodward 8440-2254 | 140CRA93100 | TRICONEX 3700A |
Yokogawa SAI533-H33/PRP | Woodward 8440-2255 | 140ACI03000 | TRICONEX 3703E |
Yokogawa SB401-10 | Woodward 8440-2150 | 140CPU11303 | TRICONEX 3721N |
Yokogawa SB401-50 | Woodward 8440-2078 | 140CPS11100 | TRICONEX 3704E |
Yokogawa SCP451-53 | Woodward 8440-1809 | 140DDO84300 | TRICONEX 4329G |
Yokogawa SDV144-S33 | Woodward 8440-2107 | 140CHS11000 | TRICONEX 4351A |
Yokogawa SDV531-L33 | Woodward 8440-1894 | 140CPS11420 | TRICONEX 4352A |
Yokogawa SDV531-L33/STB4D-00 | Woodward 8440-2078 | 140CRA93200 | TRICONEX 4354 |
Yokogawa SDV541-S33 | Woodward 8440-2077 | ILS1B853S1456 | TRICONEX 4355X |
Yokogawa SEC401-51 | Woodward 8440-1801 | 140CPU67160 | TRICONEX 3002 |