Essential details:VT-VRRA1-527 REXROTH Electrical Amplifier
lf you need to inquire or purchase ,please send the product models to my email or call medirectly .
sunny He
[Email] sales@xiongbagk.cn
[Mobile] 86-18059884797
[WhatsApp] 86-18059884797
[Skype] sales@saulcontrol.com
VT-VRRA1-527 REXROTH Electrical Amplifier
Command value call-ups [4]
Four command value signals “w1” to “w4” can be called up.
The external command value voltages (command values 1 to 4) are either defined directly by the regulated
voltage outputs +10 V and –10 V or via external potentiometers. If these command value inputs are directly connected
to the regulated voltages, the command values are set at
the potentiometers “w1” to “w4”. When using external
potentiometers, the internal potentiometers will function as
attenuators or limiters.
Only one call-up can be operated at the same time. If several call-ups are operated simultaneously, call-up “1” has
the lowest priority and call-up “4” has the highest priority.
The respective active call-up is indicated via a yellow LED
on the front plate.
Command value inversion [7]
The command value created internally from the input
signals, the command value call-ups and the zero point
offset signal can be inverted by an external signal or
jumper J1. The inversion is indicated by an LED (“–1”) on
the front plate.