Sale!

489-P5-LO-A20-T GE 489 Series for the GE Generator Management Relays

489-P5-LO-A20-T GE 489 Series for the GE Generator Management Relays

Manufacturers :GE
Model(s)  :489-P5-LO-A20-T
Additional Information :489 Series for the GE Generator Management Relays
Estimated Shipping Size
Dimensions: 263 × 58 × 28mm
Weight:.4.3 kg
Country of Origin: United States of America

 

Categories: , SKU: 489-P5-LO-A20-T

Description

Overview


Essential details:489-P5-LO-A20-T GE 489 Series for the GE Generator Management Relays

489-P5-LO-A20 Technical Specifications

Digital Inputs 489 Sensor Supply 24 VDC at 20 mA Max
Field Breaker Discrepancy Elements Trip
Ground Directional Timing Accuracy ±100 ms
Negative Sequence Overcurrent Time Delay 0.1 to 100.0 s in steps of 0.1
Neutral Voltage Input Conversion Range 0.005 to 1.00 × Full Scale
Overcurrent Alarm Timing Accuracy ±0.5% of total time
Phase Differential Pickup Level 1.01 to 1.50 × rated V in steps of 0.01

Product Description

489-P5-LO-A20 is a generator management relay that is manufactured by GE Multilin for the 489 series. This relay has 5 A phase CT secondaries. The LO control power is 20-60 VDC and 20-48 VAC at 48-62 Hz. The analog outputs on this relay are 4 to 20 mA. This relay has a basic display.

This unit has a shipping weight of 10 KG (approximate) and has dimensions of 21.6 cm (L) x 22.4 cm (W) x 25.2 cm (H).    The front panel includes multiple status LEDs as well as having input buttons, a numeric keypad, an input port, and an LCD screen for reading information at the location of the unit.

489-P5-LO-A20-T

lf you need to inquire or purchase ,please send the product models to my email or call medirectly .

sunny  He

[Email] sales@saulcontrol.com

[Mobile] 86-18059884797

[WhatsApp] 86-18059884797

[Skype] sales@saulcontrol.com

489-P5-LO-A20-T GE 489 Series for the GE Generator Management Relays

The Frequency parameter has a range of 0.00 to 90.00 Hz. The Neutral Volt (3rd) parameter has a range of 0 to 25000 V. The Average Voltage parameter has a range of 0.00 to 1.50 × the rated voltage. The Power Factor parameter has a range of 0.01 to 1.00 lead/lag. The Reactive Power (Mvar) parameter has a range -2.00 to 2.00 x the rated voltage. The Real Power parameter has a range of -2.00 to 2.00 x the rated voltage. The Apparent Power parameter has a range of 0.00 to 2.00 x the rated voltage. The Analog Inputs 1 to 4 parameters have a range of -50000 to +50000. The Tachometer parameter has a range of 0 to 7200 RPM. The Thermal Capacity Used parameter has a range of 0 to 100%. The Current Demand parameter has a range of 0.00 to 20.00 x FLA. The Mvar Demand parameter has a range of 0.00 to 2.00 x the rated voltage. The MW Demand parameter has a range of 0.00 to 2.00 x the rated voltage. The MVA Demand parameter has a range of 0.00 to 2.00 x the rated voltage.

Frequently Asked Questions about 489-P5-LO-A20

Is there a manual for the 489 Series for the GE Generator Management Relays?
Yes, there is a manual for the 489 Series for the GE Generator Management Relays, the manual can be found in a PDF format with the manual part number of 1601-0150-AE.
How many output relays does the GE Generator Management Relay 489-P5-LO-A20 have?
The GE Generator Management Relay 489-P5-LO-A20 has 6 output relays that are for alarms and trips.
How often should the 489 generator management relay be powered on?
The recommendation is that the 489 generator management relay to be powered on at least once a year to prevent deterioration to the electrolytic capacitors that contained within the power supply.