9905-753 Woodward electronic two-out-of-three Overspeed Protection Systems

9905-753 Woodward electronic two-out-of-three Overspeed Protection Systems

Manufacturers :Woodward
Model(s)  :9905-753
Additional Information :electronic two-out-of-three Overspeed Protection Systems
Estimated Shipping Size
Dimensions: 263 × 58 × 28mm
Weight:.4.3 kg
Country of Origin: United States of America

 

Categories: , SKU: 9905-753

Description

Overview


Essential details:9905-753 Woodward electronic two-out-of-three Overspeed Protection Systems

9905-753 Technical Specifications

Dimensions W482.6mm x H310.4mm x D142.7mm
Features Hot Replacement
Input Voltage 120 Vac/dc and 220 Vac
Manual 85196
Manufacturer Woodward Governor
Model De-energize-to-Trip
Operating Temperature –25 to +60 °C (–13 to +140 °F)
Standards Adequate ventilation for cooling and space for servicing

Product Description

Product 9905-753 is a digital overspeed protection device. This is a de-energize-to-trip device that has three nearly identical speed-sensing units to monitor prime mover speed and activate a trip relay in the event of overspeed detection. The only difference among the units is that two of them have a 120 Vac/dc voltage input and the third unit has a 220 Vac voltage input. Each unit has its own power supply and the system can be configured for compatibility with various power sources.

9905-8

lf you need to inquire or purchase ,please send the product models to my email or call medirectly .

sunny  He

[Email] sales@saulcontrol.com

[Mobile] 86-18059884797

[WhatsApp] 86-18059884797

[Skype] sales@saulcontrol.com

9905-753 Woodward electronic two-out-of-three Overspeed Protection Systems

The modular design of this system permits a number of functions preventing overall system failure or system downtime. The 9905-753 system has a two-out-of-three voting configuration based on three separate speed calculations. A built-in frequency generator makes it possible to test speed-sensing units one at a time while the prime mover is online. If any one of the three units trips, the other two will maintain normal operations. This also means that a single unit can be replaced without disrupting operations

A key switch is used to move between MONITOR and PROGRAM modes. The 9905-753 system will run while in either of these two modes however it should be left in MONITOR mode unless the units are actually being programmed. Tunable parameters are: MPU failed timeout, MPU gear teeth, MPU failed setpoint, trip speed setpoint, and trip on MPU failure.

Product 9905-753 has a functional status LED indicators and alarm outputs to alert operators of any errors within the system. Error codes and troubleshooting guidelines may be found online in Woodward ProTech 203 Overspeed Protection System Manual 85196.