Description
Overview
Essential details:FC-PDIO01 HONEYWELL Universal Marshalling Solution for Safety Systems
The following Universal Marshalling Solution items are included in this document.
• CC-USCA01, Universal Signal Conditioning Assembly 24 VDC
• CC-UPTA01, Pass Through Adapter 24 VDC
• FC-UDI501, Digital Input with 5K resistor Adapter 24 VDC SIL 3
• FC-UIR501, Digital Input Relay with 5K resistor Adapter 24 VDC SIL1
• FC-UDIR01, Digital Input Relay Adapter 24 VDC SIL 3
• FC-UDOR01, Digital Output Relay Adapter 24 VDC SIL 3
• FC-UDOF01, Digital Output Relay Adapter F&G 24 VDC SIL 3
• FC-UAIA01, Analog Input, 3 wire, 4-20Ma SIL 3
• FC-UAIS01, Analog input Sink, 3 wire, 4-20mA SIL 2
• FC-UDIN01, Namur proximity switch input SIL 2
• FC-UDNS01, Namur Safety proximity switch input SIL 2
• FC-UGAI01, Analog Input Barrier, SIL 2
• FC-UGAO01, Analog Output Barrier, SIL 2
• FC-UGDA01, Digital Input/Output Barrier, SIL 2
• CC-UGIA01, Universal Signal Conditioning Assembly IS 24 VDC
• FC-USCA01, Universal Signal Conditioning High Current Assembly 24 VDC
lf you need to inquire or purchase ,please send the product models to my email or call medirectly .
sunny He
[Email] sales@saulcontrol.com
[Mobile] 86-18059884797
[WhatsApp] 86-18059884797
[Skype] sales@saulcontrol.com
FC-PDIO01 HONEYWELL Universal Marshalling Solution for Safety Systems
Universal Marshaling Solution provides standardized marshalling for central and distributed installations using signal conditioning assemblies. The signal conditioning assemblies handle 16 I/O’s including disconnect, fusing as default, and when needed signal conditioning adapters (SCA) including isolation, intrinsic safety, relay, and other functions can be plugged in optionally. The SCA supports standardized cabinet assembly and wiring configurations without the need for custom wiring.
. The unique features of UMS include:
• Three level flexible field terminations are provided to cater to various field wiring requirements.
• The Signal Conditioning Adapters are plugged into the USCA to eliminate the need for a separate installation of isolators, relays, signal converters and barriers.
• USCA has integral (optional) fuse and knife disconnect for easier plant installation and maintenance.
• D-Sub connector is provided on the USCA for interfacing with the IOTA.
• Field power is supplied through the USCA via the system integration cable (SIC) from the Safety IOTA.
• Optional power connector is provided to supply power to the active signal conditioning adapters.
• Optional 16 plug and play Signal Conditioning Adapters.
• Vertical mounting for more effective wiring since most field wiring applications require entry from the top or bottom of the cabinet.
• An LED for a quick visual cue to draw the Maintenance Technician’s eye to important status information of relay and active signal conditioning adapters