Description
Overview
Essential details:1734-OE2V Allen-Bradley POINT I/O Analog Output Module
lf you need to inquire or purchase ,please send the product models to my email or call medirectly .
sunny He
[Email] sales@xiongbagk.cn
[Mobile] 86-18059884797
[WhatsApp] 86-18059884797
[Skype] sales@saulcontrol.com
1734-OE2V Allen-Bradley POINT I/O Analog Output Module
This module requires a wiring base assembly of 1734-TB, 1734-TBS, 1734-TB3, 1734-TB3S,1734-TOP, or 1734-TOPS wiring base assembly. It has integrated indicators such as 1 green/red for module status, 1 green/red for network status and 2 green/red for output status. This module keyswitch position is No.4. When wiring signal to this module, the recommended wire size are 0.25 to 2.5 sq. mm. or 22 to 14 AWG solid or stranded copper wire rated at 75 °C or 167 °F or greater and max insulation of 1.2 mm or 3/64 in.
The Allen-Bradley 1734-OE2V POINT I/O Analog Output Module with single-ended, non-isolated 2-channels that converts digitally processed data to analog output voltage. The module has a resolution of 14 bits (13 plus sign) 1.28C/cnt in unipolar or bipolar modules. Until the communication is set, it has a 0V output voltage. Its user-configurable output voltage is 0-10V. (-0.0V under, +0.5V over) +10V user configurable (-0.5V under, +0.5V over). The 1734-OE2V operates Uni-polar or Bipolar modules. Its default module mode is 0-10V DC and it has a typical mode of -10 – +10V DC. It has a default scaling point of 0 – 10000. The 1734-OE2V’s absolute accuracy comes with a 0.1% full scale at 25°C. Its accuracy drift with temperature is 5ppm/deg. C.
The Allen-Bradley 1734-OE2V has a current load on the voltage output of 3 mA with a digital to analog conversion type. Its conversion rate is 20’s, it is factory-calibrated, and it has a format of signed integers. Its max point-bus current is 75 mA at 5V DC and it has a max power dissipation of 1W. Its thermal dissipation is 3.4BTU/hr. The 1734-OE2V has an isolation voltage of 50V continuous and the module has been tested to withstand 2200V DC at 60 s. It has a nominal voltage of 24V DC and a voltage range from 10-28.8V DC. Its current supply is 35 mA at 24V DC including outputs of 3mA.
The 1734-OE2V has several indicators: 1 green/red for the module status, 1 green/red for the network status, and 2 green/red for the output status. Its dimensions are 56 x 12 x 75.5 mm. Its wire category is 1 on the signal ports. The model’s wire size is 0.25-2.5 mm2 solid or stranded copper wire rated at 75 deg. C or greater with 1.2mm insulation max. The 1734-OE2V weighs approximately 36g and its terminal base screw torque’s mass is 0.6 Nm. It has an operating temperature of -20-55 deg. C, a maximum air surrounding temperature of 55 deg. C, and a storage temperature of -40-85 deg. C. The 1734-OE2V has a relative humidity of 5-95% non-condensing and a vibration of 5g at 10-500 Hz. Its operational shock is 30g and its non-operational shock is 50g. The 1734-OE2V module produces 0 Volts output before communication is established. Once communication is established, the output voltage is user-configurable anywhere from 0-10 Volts. Additionally, the 1734-OE2V module’s current load on voltage output is 3 mA.