Description
概观
Essential details:DC-TDIL51 PlantCruise by Experion Specification
As a member of Honeywell’s Experion family, PlantCruise by Experion is specifically designed to meet the customer needs in emerging markets, through integrating state-of-the-art technology from the award-winning Experion Process Knowledge System (PKS) with innovative design of Series 8 I/O modules and cabinets, validated wider range of COTS options, easier engineering and maintenance capabilities, and integrator-friendly programs and tools. PlantCruise is the perfect platform for process, asset and business management with small to medium complexity, and enables customers to increase their profitability and productivity and accessibility to local support without sacrificing quality and reliability in an increasingly competitive environment.
The PlantCruise platform comprises many different integrated hardware and software solutions depending upon the needs of the application. This pictured architecture is a representation of many of the possible nodes that can be used in the PlantCruise architecture. Note that the architecture is highly scalable and not all nodes are necessary or required.
lf you need to inquire or purchase ,please send the product models to my email or call medirectly .
sunny He
[Email] sales@saulcontrol.com
[Mobile] 86-18059884797
[WhatsApp] 86-18059884797
[Skype] sales@saulcontrol.com
DC-TDIL51 PlantCruise by Experion Specification
• Input Output Termination Assembly (IOTA): An assembly that holds the IOM and the connections for field wiring,
• Input Output Module (IOM): A device that contains most of the electronics required to perform a specific I/O function. The IOM plugs onto the IOTA.
Features
All Series 8 components feature an innovative design that supports enhanced heat management. This unique look provides a significant reduction in overall size for the equivalent function.
The unique features of Series 8 I/O include:
• I/O Module and field terminations are combined in the same area. The I/O Module is plugged into the IOTA to eliminate the need for a separate chassis to hold the electronics assemblies
• Two level “detachable” terminals for landing the field wiring in the enclosure, providing easier plant installation and maintenance.
• Field power is supplied through the IOTA, with no need for extra power supplies and the associated craft wired marshalling.
• Redundancy is accomplished directly on the IOTA without any external cabling or redundancy control devices, by simply adding a second IOM to an IOTA
• For both IOM and IOTA, coated (module numbers starting with 8C) and uncoated (module numbers starting with 8U) options are provided. Conformal coating material is applied to electronic circuitry to act as protection against moisture, dust, chemicals, and temperature extremes. Coated IOM and IOTA are recommended when electronics must withstand harsh environments and added protection is necessary.
The Series 8 inherits the innovative styling of Series C. This styling includes features to facilitate the effective use of control hardware in a systems environment. These features include:
• Vertical mounting allows for more effective wiring since most field wiring applications require entry from the top or bottom of the systems cabinet.
• An “information circle” allows for a quick visual cue to draw the Maintenance Technician’s eye to important status information.
04220FL11232A Intelligent Platforms Rxi Controller | PCIE-6321 DIO Multifunction I/O Device |
LDGRB-01 3BSE013177R1 I/O Programmable Logic module | PCIE-1427 779706-01 Frame Grabber |
CI854AK01 3BSE030220R1 PROFIBUS-DP/V1 interface | IC695CHS007 Universal backplane RX3i and Series 90-30 I/O and option modules |
TRICON 3511 TRICONEX Pulse input module | IC697CMM742-DC Series 90-70 Communications Module |
TRICON 3503E TRICONEX Digital input module | FC-TSRO-0824 Digital Output Field Termination Assembly |
TRICON 3625 TRICONEX Digital input module | MVC3001-4003A ALSPA MV3000 Delta Controller |
D674A906U01 Cartridge U-high HART | 6SM57M-3.000 Synchronous Servomotors |
VT-HNC100-1-23/W-08-0-0 R900955334 VT-HNC100 Digital Axis Controllers | 05701-A-0282 Modbus Interface Module Kit RS422/485 |
1X00416H01 POWER SUPPLY 24V 300W & 25V 500W OUT DIN-RAIL MOUNT | 3500/91 190782-01 EGD gateway module |
5X00241G02 Ovation Westinghouse Controller module | 05701-A-0361 System 57 MODBUS Interface |
489-P5-LO-A20 generator management relay | 3500/65 145988-02 16-Channel Temperature Monitor |
TRICON 3805E TRICONEX Analog Output Modules | 3500/65 172103-01 16-Channel Temperature Monitor |
5X00226G02 Ovation Westinghouse Controller module | 136188-02 Ethernet/RS485 Modbus I/O Module |
MC-4/11/10/400 PowerDrive Motion Controller | PCI-6733 Analog Output Device |
2MLR-CPUH/T MasterLogic Programmable Logic Controller | 3ASC25H209 DATX110 I/O board control module |
KJ4002X1-BA1 Left 8 Wide Vertical Carrier | CE4002S1T2B5 Standard I/O Termination Block |
S72402-NANANA S700 digital servo drive | CE4005S2B4 Standard I/O Termination Block |
SCYC55830 58063282A Trigger plate | PCI-4462 Sound and Vibration Device |
IC697CMM742-DC Ethernet Interface Communications Modules | TU890 3BSC690075R1 compact MTU for the S800 I/O |
PPC322BE1 HIEE300900R1 Industrial drive function module | KJ4001X1-BE1 12P0818X072 REV:L 8 Wide I/O Carrier with Shield Bar |
VMIVME-3122 High-Performance 16-Bit Analog-to-Digital Converter (ADC) | KJ2201X1-JA1 Redundant SLS Terminal Block |
TVME200-10 6U VMEbus Carrier for up to 4 singlesize or 2 double-size IndustryPack (IP) modules | AI895 3BSC690089R1 Analog Input Module |
VMIVME-2540 Intelligent Counter/Controller | AO2000 LS25 Advance Optima process analyzer’s modular |