Description
概观
Essential details:IS230PCAAH1B CORE ANALOG I/O MODULE
Part Number: IS230PCAAH1B
Manufacturer: General Electric
Series: Mark VIe
Product Type: I/O Module
Number of Inputs: 25
Number of Outputs: 4-20 mA
Analog 0-10 V DC Inputs: ±0.50%
LVDT Excitation Monitor Input: ±1.00%
Servo Driver Output: ±3.50%
Power Supply Input Voltage: 28Vdc±5%
Size: 33.02cm high x17.8 cm wide
Technology: Surface-Mount
Operating Temperature: -30 to 65oC
Availability: In Stock
Product of Origin: U.S.A
Manual: GEH-6721L
FUNCTIONAL DESCRIPTION
IS230PCAAH1B is a Core Analog I/O Module manufactured and designed by General Electric as part of the Mark VIe Series used in distributed control systems. A sizable amount of the analog signal I/O needed to run a gas turbine is provided by the Core Analog (PCAA) module and related Core Analog (TCAS and TCAT) terminal board. Thermocouple, 4-20 mA current loop, seismic, linear variable differential transformer (LVDT) excitation and inputs, pulse rate, and servo coil outputs are all provided by PCAA and TCAT. In simplex, dual, and TMR systems, PCAA is applicable. To one, two, or three linked PCAA modules, a single TCAT terminal board fans signal inputs. In addition to the terminals on PCAA and TCAT, a nearby JGPA board also has shield ground and 24 V field power connectors.
lf you need to inquire or purchase ,please send the product models to my email or call medirectly .
sunny He
[Email] sales@saulcontrol.com
[Mobile] 86-18059884797
[WhatsApp] 86-18059884797
[Skype] sales@saulcontrol.com
IS230PCAAH1B CORE ANALOG I/O MODULE
Fig 1: PCAA Core Analog
- Two application I/O boards, a terminal board, and a processor board that is shared by all Mark* VIe distributed I/O are all included in PCAA. The various boards that make up the module are not supported for diagnosis or replacement, making the entire module the least changeable component.
- Dual RJ45 Ethernet connectors and the 28 V dc power connector P5 are used to supply the module with input. 120 box terminals in the Euro style are located on the module edge and are used for field device I/O. Connector P4 provides power to a JGPA board. Two 68-pin cables on connectors P1 and P2 are used to connect the module to the TCAT.
- PCAA divides the signals into two categories. The TCAT terminal board is used to route signal inputs that can be fanned from a single input into a single, dual, or TMR PCAA module. The terminals of PCAA are wired with signals that are exclusive to a single PCAA module. As a result, the signal split in the following table is produced. If the fanned inputs are not necessary, PCAA can be used in place of TCAT.
Each Mark VIe I/O pack and controller is fully compatible with the PCAA module. The following table lists the frame rates, redundancy, and networking that PCAA supports.
INSTALLATION:
- Mount the PCA A module firmly.
- Attach the P4 connector on the PCAA to the JGPA power connection.
- Attach two 68-pin cables to connectors P1 and P2 on a TCAT terminal board that is optionally coupled with the PCAA module. A network connection pairs the connectors on TCAT. PS1 and PS2 connect to a PCAA that is part of the S controller network, PT1, and PT2 connect to a PCAA that is part of the T controller network, and PR1 and PR2 connect to a PCAA that is part of the R controller network.
- To maintain adequate cable grounding, it is crucial to just finger-tighten the mounting screws into PCAA and TCAT. If the wires are not secured, PCAA may be unable to read the electronic ID on TCAT, which could degrade other communications.
- Depending on the setup of the machine, connect either one or two Ethernet wires. The module works properly over either port when a single IONet connection is utilized. The R controller’s network should be connected to ENET1 if dual connections are being used.
- The PCAA, however, does not care how an Ethernet connection is made and negotiates correct functionality via either port. The network connection should match the connection made to TCAT if TMR PCAA modules are present. For instance, cables to the TCAT PR1 and PR2 connectors should be present on the PCAA module with the R IONet connection.
- Verify that the JGPA shield wire terminals are grounded. The JGPA shield ground connections are typically electrically connected to the sheet metal that the board is mounted on. The ground path for the terminals is then provided by the mounting.
- It may be necessary for some situations to specify a shield ground that is separate from the mounting sheet metal. The JGPA is mounted in these applications utilizing hardware that separates the board from the sheet metal. Between one or more JGPA terminals and the necessary shield ground potential in these applications, a suitable ground wire must be provided.
- Check the power and Ethernet status indicator lights after powering on the module using the P5 connector.
IS420ESWBH3AX GE Analog I/O modules | 147663-01 BENTLY Communication analog output module |
516TX 336A4940DNP516TX GE 516TX-A Industrial Ethernet Switch | 125800-01 Bently Nevada Key phase input/output module |
128277-01 Future Expansion Faceplate Bently Nevada | 140471-01 Bently Nevada Developed I/O module with internal terminal |
A413139 PC BOARD CIRCUIT BOARD MODULE ASSEMBLY METSO | 3500/22M 138607-01 Bently Detector module |
D201471 Metso RT node PC AP31 D200137 personality module | 3500/94 145988-01 BENTLY Display module |
A413188 PC BOARD CIRCUIT BOARD MODULE ASSEMBLY METSO | 3500/42M 176449-02 bently nevada Shaft vibration module |
A413331 PC BOARD CIRCUIT BOARD MODULE ASSEMBLY METSO | 3500/92 136180-01 bently nevada Communication gateway module |
D201466 Metso RT node PC AP31 D200137 personality module | 136180-01 Bently Nevada Communication gateway module |
85UVF1A-1QD Fireye Integrated Flame Scanner with Internal Flame Relay | 3500/92-03-01-00 Bently Nevada 3500/92-03-01-00 |
516TX 336A4940DNP516TX GE A microprocessor device | 7264 ABB The four-channel SSI interface module features automatic |
516TX-336A4940DNP516TX GE microcontroller | MDB-8E SARTORIUS Load cell |
2MLR-CPUHT HONEYWELL CPU HT bus function | 3500/15 127610-01 Bently Nevada Digital input module |
177313-01-01 BENTLY NEVATA Vibration monitoring module | 3500/50 133388-02 BENTLY NEVADA Tachometer monitoring module 4 channels |
PXIE-6556 NI Automatic industrial control module | 3500/40-03-00 176449-01 BENTLY NEVADA Expansion axial position module |
PFCL201CE ABB Pressure sensor controller | 3500/15 Plastic panel BENTLY NEVADA Ac and DC power supplies |
MTL BPHM64 Eaton Safety grid base plate | X20CP1586 B&R The core product of B&R’s I/O system line |
1794-IF4IXT Allen Bradley Flex I/O 1794 series input module | IC698PSA350 GE High capacity power module |
1734-IM4 Allen Bradley POINT I/O 4 Point Digital Input Module | VMIVME 3215-000 GE Computer module |
1769-ECR Allen-Bradley Right end cover (ECR) module used together | 201TI GE Microprocessor-based electrical transmitter |
136188-02 Bently Nevada Ethernet /RS232 Modbus I/O module | 3500/05-01-02-00-00-01 BENTLY System rack |
AI02J ABB Analog input module | PM865K02 ABB controller |
DSSA165 ABB Ac power module | 3500/22-01-01-00 138607-01 BENTLY Transient data interface before and after the size card module |
PXIe-1073 NI PXI Chassis | IS420UCSBH4A GE Controller module manufactured by General Electric |
F860-CA HONEYWELL Series C “fieldbus interface module | D201376 METSO Analog input module |
DSSA165 ABB Ac power module | D201376 METSO Analog input module |
125840-02 Bently Power module | IS420UCSBH4A GE Controller module manufactured |