Description
概观
Essential details:G123-815A001 Buffer Amplifier interfaces
lf you need to inquire or purchase ,please send the product models to my email or call medirectly .
sunny He
[Email] sales@saulcontrol.com
[Mobile]Â 86-18059884797
[WhatsApp] 86-18059884797
[Skype] sales@saulcontrol.com
G123-815A001 Buffer Amplifier interfaces
3.4 EMC
The G123-815 emits radiation well below the level called for inits CE mark test. Therefore, no special precautions are requiredfor suppression of emissions. However, immunity from externalinterfering radiation is dependent on careful wiring techniques.The accepted method is to use screened cables for allconnections and to radially terminate the cable screens, in anappropriate grounded cable gland, at the point of entry intothe industrial steel enclosure. lf this is not possible, chassisground screw terminals are provided on the G123-815.Exposed wires should be kept to a minimum length. Connectthe screens at both ends of the cable to chassis ground.
4 Power supply
24V nominal, 22 to 28V20mA @ 24V without a load, 145mA @ 100mA load.If an unregulated supply is used, the bottom of the ripplewaveform is not to fall below 22V
It is recommended that the M205, 250mAT (slow blow) fuse,supplied with the unit, be placed in series with the +24V inputto protect the electronic circuit. There is a spare fuse in thecover of the fuse holder. Replacement fuses should becompliant with lEc 127-2 sheet 3.