Essential details:SPM-D2-10 SPM-D2-10/YB Synchronizing Unit
lf you need to inquire or purchase ,please send the product models to my email or call medirectly .
sunny He
[Email] sales@saulcontrol.com
[Mobile]Â 86-18059884797
[WhatsApp] 86-18059884797
[Skype] sales@saulcontrol.com
SPM-D2-10 SPM-D2-10/YB Synchronizing Unit
Output of an add-on order for the power circuit breaker without synchronization, if the following conditions are fulfilled:
ï‚· The dead bus start function is in principle activated by configuration
ï‚· One of the three possible dead bus start functions is selected by configuration
ï‚· The discrete input “Dead bus start release” is energized
ï‚· The discrete input “Release CB” is energized
ï‚· The discrete input “Reply: CB is open” is energized
ï‚· The conditions for one of the preset dead bus start functions are fulfilled:
a) U1 has the value Un (taking the configured rated voltage difference into account dV |V-V zero (taking the configured zero voltage difference into account dV |V-0|).
b) U1 is zero (taking the configured zero voltage difference into account dV |V-0|) and U2 has the value V (taking the configured rated voltage difference into account dV |V-V
c) U1 is zero and U2 is zero (taking each configured zero voltage difference into account dV |V-0|). Moreover, in case a) and b) the frequency of U1 and U2 must be within the configured limits.
Synch-Check
In this condition, the unit can be used as a synchronization control. No control is carried out. The relay “CB close” remains picked up, as long as the following conditions are met:
ï‚· The voltage differential is within the configured limit (screen “synchronization dV
ï‚· The frequency differential is within the configured limit (screens “synchronization df
ï‚· The phase angle is within the configured limit (screen “slip synchron. phi
ï‚· The discrete input “Reply: CB is open” is energized
ï‚· The discrete input “Enable CB” is energized
ï‚· The systems U1 and U2 are within the permitted limits (see Table 5-2: Operating modes – operating conditions, condition A, page 16).
ï‚· The discrete input “Synch-check” is energized.
The synchronization time monitoring must be deactivated.
3500/25 149369-01Â Keyphasor module | 6SM57M-3.000Â Synchronous Servomotors |
3500/92 136180-01Â Keyphasor module | 05701-A-0282Â Modbus Interface Module Kit RS422/485 |
1X00416H01Â POWER SUPPLYÂ 24V 300W & 25V 500W OUT DIN-RAIL MOUNT | 3500/91 190782-01Â EGD gateway module |
5X00241G02 Ovation Westinghouse Controller module | 05701-A-0361 System 57 MODBUS Interface |
489-P5-LO-A20Â generator management relay | 3500/65 145988-02Â 16-Channel Temperature Monitor |
TRICONÂ 3805EÂ TRICONEXÂ Analog Output Modules | 3500/65Â 172103-01 16-Channel Temperature Monitor |
5X00226G02 Ovation Westinghouse Controller module | 136188-02 Ethernet/RS485 Modbus I/O Module |
MC-4/11/10/400Â PowerDrive Motion Controller | PCI-6733Â Analog Output Device |
2MLR-CPUH/T  MasterLogic Programmable Logic Controller | 3ASC25H209 DATX110  I/O board control module |
KJ4002X1-BA1Â Left 8 Wide Vertical Carrier | CE4002S1T2B5Â Standard I/O Termination Block |
S72402-NANANAÂ S700Â digital servo drive | CE4005S2B4Â Standard I/O Termination Block |
SCYC55830 58063282AÂ Trigger plate | PCI-4462Â Sound and Vibration Device |
IC697CMM742-DC Ethernet Interface Communications Modules | TU890 3BSC690075R1 compact MTU for the S800 I/O |
PPC322BE1 HIEE300900R1Â Industrial drive function module | KJ4001X1-BE1 12P0818X072 REV:LÂ 8 Wide I/O Carrier with Shield Bar |
VMIVME-3122Â High-Performance 16-Bit Analog-to-Digital Converter (ADC) | KJ2201X1-JA1Â Redundant SLS Terminal Block |
TVME200-10Â 6U VMEbus Carrier for up to 4 singlesize or 2 double-size IndustryPack (IP) modules | AI895 3BSC690089R1Â Analog Input Module |
VMIVME-2540Â Â Intelligent Counter/Controller | AO2000 LS25Â Advance Optima process analyzer’s modular |
PPD513A24-110110Â AC 800PEC Controller | PCIE-6321Â NIÂ Multifunction I/O Device |
GFD563Â AC 800PEC Controller | CI627A 3BSE017457R1Â AF100 communication interface |
S-113N 3BHB018008R0001Â Phase module | 1900/65A-00-00-01-00-00Â 1900/65A General Purpose Equipment Monitor |
S-093H 3BHB030478R0009Â Phase module | IS220PDOAH1A 336A4940CSP2Â Discrete Output Pack |
3BHE046836R0102 GFD563A102Â AC 800PEC system excitation controller | A6370DÂ Â Digital Overspeed Protection System |
MVR1600-4601Â Air Cooled Rectifier Module | SLS1508Â DeltaV SISâ„¢ Logic Solver |