Essential details:TRICONEX 3301 Digital Input Module
Products Description
- Manufacturer : Triconex
- Product No. : 3301
- Product type : Digital Input Module
- Application Processor
- SX Processor : Motorola MPC860, 32-bit, 50 MHz
- Flash PROM : 6 MB used for SX, IOX, and control application storage CRC-protected
- DRAM : 16 MB used for SX control application execution and program and SOE data Byte parity
- NVRAM : 8 KB, used for retentive variables CRC-protected
- Input/Output Processor
- IOX Processor : Motorola MPC860, 32-bit, 50 MHz
- DRAM : 16 MB, used for IOX execution Byte parity
- Shared memory : 128 KB, used to communicate with SX Byte parity
- Diagnostic bus : 2 Mbps HDLC, used to communicate I/O module diagnostic information between MP channels
- Logic Power
- Nominal input voltage : 24 V DC
- Operational voltage range : 24 V DC –15%/+20% + 5% AC ripple (+19.2 / +30 V DC)
- Logic power : 8 W maximum
- Absolute maximum input voltage : 33 V DC
- Absolute maximum reverse input voltage : –0.6 V DC
- Weight : 1.5 Kg
- Shipping weight : 3 Kg
1 | Points | 32, commoned |
2 | Nominal input voltage | 24 VDC |
3 | Operational voltage range | 15–30 VDC |
4 | Absolute maximum input voltage | 33 VDC |
5 | Absolute maximum reverse input voltage | – 0.6 VDC |
6 | Input delay | <10 ms, On to Off or Off to On TC = 6.4 ms, –3dB @ 25Hz |
7 | Input impedance | >30 k:, without baseplate |3 k:, with baseplate |
8 | Input power | 0.2 W/pt, @ 24 VDC 0.5 W/pt, @ 33 VDC |
9 | Input threshold | 0–5 VDC = Off region 6–14 VDC = transition region 15–30 VDC = On region |
10 | Diagnostic (loss of view) | Force-to-value diagnostic (FVD), <2 ms/test |
11 | Maximum input toggle rate to maintain diagnostic fault coverage | <20/sec |
12 | FVD Off state glitch Duration Magnitude Output Impedance |
<2 ms about 36% test voltage 0–5 VDC, about 100 k: |
13 | ADC scan time | <1 ms for all 32 points |
14 | Functional earth to protective earth isolation | 500 VDC, minimum |
15 | Functional earth to functional earth (logic ground) isolation | 800 VDC, minimum |
16 | Origin Country | Made in U.S.A |
17 | Supplier | Aotewell |
Digital Input Module Each TMR Digital Input Module has three isolated sets of electronics, called channels, which independently process field data to the module. Each channel places the processed data in an array and transmits this array, on request, to the MP associated with that channel. The MPs vote on the data before passing it to the application. DI Modules include complete, ongoing diagnostics for each channel. If the diagnostics detect a failure on any channel, the Fault indicator turns on and activates the system alarm. The Fault indicator identifies a channel fault, not a complete module failure. The DI Module continuously verifies the ability of the system to detect transitions to the opposite state. DI Modules are guaranteed to operate properly in the presence of a single fault and may continue to operate properly with multiple faults. DI Modules support a hot-spare module. Each DI Module is mechanically keyed to prevent improper installation in a configured baseplate. The Model 3301 DI Module can be used with these baseplates: • Model 2301, which is used with typical applications. • DI External Termination Baseplate, which is used with the Solid State Relay Input External Termination Panel in high-voltage applications, or the Model 9573-610 DI Hazardous Location External Termination Panel.
Why Choose Us TRICONEX 3301 Digital Input Module
We are a professional service provider in the field of industrial automation components. We mainly provide PLC module, DCS card, ESD system card, vibration monitoring system card, turbine control system module, gas generator components, we have established a close cooperative relationship with many PLC and DCS product maintenance service providers. The company has established an e-commerce operation model, which reduces the intermediate links for consumers and provides consumers with high-quality products and satisfactory services. The company has a complete logistics supply system. We can buy directly from abroad and supply equipment and spare parts from different countries and manufacturers to solve your problem.
Packing & Shipping
Package Type: New and original factory separately sealed inner box
Delivery time: Prepare delivery inventory;
The goods will be packed according to the international standard.
1. We will deliver the goods within 3 working days after payment.
2. The new and original factory seal the inner box separately
3. We can send it to you by DHL/TNT/UPS/EMS/ fedex.
Please contact us directly and we will deliver the goods according to your requirements. Best quality assurance
4. We promise that all goods we supply are 100% new and original
5. One year warranty (after delivery date).
Payment method: We accept telegraphic transfer
Superiority products TRICONEX 3301 Digital Input Module
TRICONEX | EPRO | EMERSON | Ics Triplex |
TRICONEX 4119 | PR9268/201-000 | KJ3203X1-BA1 | ICS T8110C |
TRICONEX 4200 | PR9268/202-000 | KJ3001X1-BB1 | ICS T9451 |
TRICONEX 3721 | PR9268/202-100 | KJ2003X1-BA2 | ICS T9432 |
TRICONEX 4351B | PR9268/301-000 | KJ3242X1-BK1 | ICS T9402 |
TRICONEX 3700A | PR9268/301-100 | FX-3161 | ICS T9110 |
TRICONEX 3703E | PR9268/302-100 | SLS1508 | ICS T8110B |
TRICONEX 3721N | PR9268/206-100 | VE3008 | ICS T9310-02 |
TRICONEX 3704E | PR9268/601-000 | CE3008 | ICS 1433/09232486825 |
TRICONEX 4329G | PR6423/013-110 | SE3008 | ICS FAIR-RITE VO |
TRICONEX 4351A | PR6423/014-030 | VE3007 | ICS T8480C |
TRICONEX 4352A | PR6423/10R-030 | VE3006 | ICS T8191 |
TRICONEX 4354 | PR6423/010-140 | SE4006P2 | ICS T8300 |
TRICONEX 4355X | PR6424/010-140 | A6500-UM | ICS T8100 |
TRICONEX 3002 | PR6423/003-030+CON021 | A6500-RC | ICS T8431 |
TRICONEX 3006 | PR6423/002-041 | A6140 9199-00058 | ICS T8403 |
TRICONEX 3008 | PR6423/00R-111 | A6370D | ICS T8310 |
TRICONEX 3009 | PR6423/003-131 | 1X00416H01 | ICS T8151B |
TRICONEX 3503E | 3500/22M-01-01-01 | CE4003S2B1 | ICS T8461 |
TRICONEX 3511 | 3500/22M | Woodward 8440-1868 | ICS TC-305-01-5M0 |