Sale!

SDV144-S13/B4D00  Digital I/O Modules (for FIO)

*1: These voltages show the case using the field power supply floating. When the field power supply is grounded, the system (functional) ground is connected to the field ground, which is not isolated. For the higher noise immunity, floating the field power supply is recommended.
*2: When the withstanding voltage of the field power supply between the secondary side and the ground is lower than the value shown in the table above, these voltages are adopted as the withstanding voltage of the field power supply.

Categories: ,

Description

概观


Essential details:SDV144-S13/B4D00  Digital I/O Modules (for FIO)

*1: These voltages show the case using the field power supply floating. When the field power supply is grounded, the system (functional) ground is connected to the field ground, which is not isolated. For the higher noise immunity, floating the field power supply is recommended.
*2: When the withstanding voltage of the field power supply between the secondary side and the ground is lower than the value shown in the table above, these voltages are adopted as the withstanding voltage of the field power supply.
*3: Number of input channels which a user can use and external power supply are restricted in case of SDV144-SC. Refer to “ProSafe-RS Outline of I/O Modules (for FIO)” (GS 32P06K60-01EN).
*4: The contact rating and the external power supply of SDV144 style code S1, S2 and S3 are 24 V DC ± 5 %.
*5: When connecting SDV144 and SED4D terminal board using the dedicated signal cable, the withstand voltage is 500 V AC (between input signal lines and system). If MIL connector cables are used, the withstand voltage depends on their cable’s electrical specifications.

SEC401-51

lf you need to inquire or purchase ,please send the product models to my email or call medirectly .

sunny  He

[Email] sales@saulcontrol.com

[Mobile] 86-18059884797

[WhatsApp] 86-18059884797

[Skype] sales@saulcontrol.com

SDV144-S13/B4D00  Digital I/O Modules (for FIO)

If SDV144 field wiring diagnostic functions are used, the following diagnostic elements should be installed for individual channels in the vicinity of the field equipment:
• SCB100 (for defective open circuit detection while accepting off signals) (*1)
• SCB110 (for defective short-circuit detection while accepting on signals) (*2)
*1: Input signals are normally off while in normal operation.
*2: Input signals are normally on while in normal operation.
When the input signals are normally off while in normal operation, connect the SCB100 in parallel with the contact output of the field equipment as given below.

*1: These voltages show the case using the field power supply floating. When the field power supply is grounded, the system (functional) ground is connected to the field ground, which is not isolated. For the higher noise immunity, floating the field power supply is recommended.
*2: When the withstanding voltage of the field power supply between the secondary side and the ground is lower than the value shown in the table above, these voltages are adopted as the withstanding voltage of the field power supply.
*3: Number of output channels which a user can use and maximum load current are restricted in case of SDV531-LC. Refer to “ProSafe-RS Outline of I/O Modules (for FIO)” (GS 32P06K60-01EN).
*4: External power supply of SDV531-S style code S1 and S2 is 24 V DC ± 5%.
*5: Do not exceed this value, including the case of inrush/variation of the load current.
*6: Resistance value of the load for both ON and OFF state, including the field wiring resistance.
*7: When connecting SDV531 and SED4D terminal board using AKB331 dedicated signal cable, the withstand voltage is 500 V AC (between output signal lines and system). If MIL connector cables are used, the withstand voltage depends on their cable’s electrical specifications.
*8: AKB651 can be used for connection with SDV531-L only

3500/25 149369-01  Keyphasor module 6SM57M-3.000  Synchronous Servomotors
3500/92 136180-01  Keyphasor module 05701-A-0282  Modbus Interface Module Kit RS422/485
1X00416H01  POWER SUPPLY  24V 300W & 25V 500W OUT DIN-RAIL MOUNT 3500/91 190782-01  EGD gateway module
5X00241G02  Ovation Westinghouse  Controller module 05701-A-0361  System 57 MODBUS Interface
489-P5-LO-A20  generator management relay 3500/65 145988-02  16-Channel Temperature Monitor
TRICON  3805E  TRICONEX  Analog Output Modules 3500/65  172103-01 16-Channel Temperature Monitor
5X00226G02  Ovation Westinghouse  Controller module 136188-02 Ethernet/RS485 Modbus I/O Module
MC-4/11/10/400  PowerDrive Motion Controller PCI-6733  Analog Output Device
2MLR-CPUH/T   MasterLogic  Programmable Logic Controller 3ASC25H209  DATX110   I/O board control module
KJ4002X1-BA1  Left 8 Wide Vertical Carrier CE4002S1T2B5  Standard I/O Termination Block
S72402-NANANA  S700  digital servo drive CE4005S2B4  Standard I/O Termination Block
SCYC55830 58063282A  Trigger plate PCI-4462  Sound and Vibration Device
IC697CMM742-DC  Ethernet Interface  Communications Modules TU890 3BSC690075R1  compact MTU for the S800 I/O
PPC322BE1 HIEE300900R1  Industrial drive function module KJ4001X1-BE1 12P0818X072 REV:L  8 Wide I/O Carrier with Shield Bar
VMIVME-3122  High-Performance 16-Bit Analog-to-Digital Converter (ADC) KJ2201X1-JA1  Redundant SLS Terminal Block
TVME200-10  6U VMEbus Carrier for up to 4 singlesize or 2 double-size IndustryPack (IP) modules AI895 3BSC690089R1  Analog Input Module
VMIVME-2540   Intelligent Counter/Controller AO2000 LS25  Advance Optima process analyzer’s modular
PPD513A24-110110  AC 800PEC Controller PCIE-6321  NI  Multifunction I/O Device
GFD563  AC 800PEC Controller CI627A 3BSE017457R1  AF100 communication interface
S-113N 3BHB018008R0001  Phase module 1900/65A-00-00-01-00-00  1900/65A General Purpose Equipment Monitor
S-093H 3BHB030478R0009  Phase module IS220PDOAH1A 336A4940CSP2  Discrete Output Pack
3BHE046836R0102 GFD563A102  AC 800PEC system excitation controller A6370D   Digital Overspeed Protection System
MVR1600-4601  Air Cooled Rectifier Module SLS1508  DeltaV SIS™ Logic Solver