PM862K01  PM862AK01  AC 800M Controller 

The CPU board contains the microprocessor and RAM memory, a real-time clock, LED indicators, INIT push button, and a CompactFlash interface.
The base plate of the PM862 controller has two RJ45 Ethernet ports (CN1, CN2) for connection to the Control Network, and two RJ45 serial ports (COM3, COM4). One of the serial ports (COM3) is an RS-232C port with modem control signals, whereas the other port (COM4) is isolated and used for the connection of a configuration tool. The controller supports CPU redundancy for higher availability (CPU, CEX-Bus, communication interfaces and S800 I/O).

Categories: ,

Description

Overview


Essential details:PM862K01  PM862AK01  AC 800M Controller 

The CPU board contains the microprocessor and RAM memory, a real-time clock, LED indicators, INIT push button, and a CompactFlash interface.
The base plate of the PM862 controller has two RJ45 Ethernet ports (CN1, CN2) for connection to the Control Network, and two RJ45 serial ports (COM3, COM4). One of the serial ports (COM3) is an RS-232C port with modem control signals, whereas the other port (COM4) is isolated and used for the connection of a configuration tool. The controller supports CPU redundancy for higher availability (CPU, CEX-Bus, communication interfaces and S800 I/O).

Simple DIN rail attachment / detachment procedures, using the unique slide & lock mechanism. All base plates are provided with a unique Ethernet address which provides every CPU with a hardware identity. The address can be found on the Ethernet address label attached to the TP830 base plate.

(Only compatible with System 800xA 6.0.2, Compact Control Builder 6.0.0-1 and onwards. Please see Product Update for more information.)

Features and benefits

•  ISA Secure certified – Read more
•  Reliability and simple fault diagnosis procedures
•  Modularity, allowing for step-by-step expansion
•  IP20 Class protection without the requirement for enclosures
•  The controller can be configured with 800xA control builder
•  The controller has full EMC certification
•  Sectioned CEX-Bus using a pair of BC810 / BC820
•  Hardware based on standards for optimum communication connectivity
(Ethernet, PROFIBUS DP, etc.)
•  Built-in redundant Ethernet Communication ports

PM862K02

lf you need to inquire or purchase ,please send the product models to my email or call medirectly .

sunny  He

[Email] sales@xiongbagk.cn

[Mobile] 86-18059884797

[WhatsApp] 86-18059884797

[Skype] sales@saulcontrol.com

PM862K01  PM862AK01  AC 800M Controller

• The controller must not be exposed to conditions that exceed the values given in the relevant technical specifications.
• The controller must not be used in an environment exposed to strong electrical interference. Electrical machines can produce interference that exceeds levels permitted for the equipment, for example during repair work.
• All products must be handled with appropriate precautions with regard to electrostatic damage.
• The controller must not be exposed to direct sunlight.
Important Software Check
• Use the system’s fault-monitoring facilities to prevent accidents or mishaps.
• When in doubt, ALWAYS CHECK before executing changes.
Important Hardware Notice
• DO NOT, under any circumstances, disconnect the power supply to a normally functioning system. Always use the correct system shut-down procedure prior to disconnecting the power supply.
Signal Noise Due to Cables
Cables which may cause electrical interference (for example, power supply cables) must not be installed adjacent to bus cables carrying fast digital signals. Ensure that a minimum distance of 10 cm (4 in.) is provided between cables installed inside cabinets.
Hazardous Electrical Supplies
Operational and maintenance procedures, during which personnel may come into contact with high voltage, should only be carried out by personnel fully trained in the maintenance of electrical equipment within those environments, and who are fully aware of all risks involved.