Sale!

FBM212 P0914XL  Differential Thermocouple/mV Input Module

The Differential Thermocouple/mV Input Module (FBM212) contains 14 differentially isolated thermocouple input channels, and one differentially isolated RTD reference junction temperature compensation channel (for terminal temperature sensing). Each thermocouple/mV channel accepts standard thermocouples for various temperature ranges, and each provides thermocouple burnout detection (up-scale). Each channel has a differential input to allow voltage differences between channels without introducing detected errors.
The module performs the signal conversion required to interface the electrical input signals from the field sensors to the optionally redundant Fieldbus. It executes an analog input application program, which provides configurable options for Conversion Time and Rate of Change Limits.
Categories: ,

Description

Overview


Essential details:FBM212 P0914XL  Differential Thermocouple/mV Input Module

The Differential Thermocouple/mV Input Module (FBM212) contains 14 differentially isolated thermocouple input channels, and one differentially isolated RTD reference junction temperature compensation channel (for terminal temperature sensing). Each thermocouple/mV channel accepts standard thermocouples for various temperature ranges, and each provides thermocouple burnout detection (up-scale). Each channel has a differential input to allow voltage differences between channels without introducing detected errors.
The module performs the signal conversion required to interface the electrical input signals from the field sensors to the optionally redundant Fieldbus. It executes an analog input application program, which provides configurable options for Conversion Time and Rate of Change Limits.
Features
• 14 channels for input of thermocouple signals
• 1 isolated RTD reference junction compensation channel (for terminal temperature sensing)
• Each channel has a differential input
• Rugged design suitable for enclosure in Class G3 (harsh) environments
• Execution of an analog input application program that provides conversion time and configurable options for Rate of Change Limits
• High accuracy achieved by sigma-delta data conversions for each channel
• Termination Assemblies (TAs) for locally or remotely connecting field wiring to the FBM212
High Accuracy
For high accuracy, the module incorporates a multiplexed Sigma-Delta converter, which can provide new analog input readings every 500 ms, and a configurable integration period to remove any process noise and power line frequencies. Each update time period, the Foxboro DCS Fieldbus Module (FBM) converts each analog input to a digital value, averages these values over the time period and provides the averaged value to the controller.
Standard Design
FBM212 has a rugged extruded aluminum exterior for physical protection of the circuits. Enclosures specially designed for mounting the FBMs provide various levels of environmental protection, up to harsh environments, per ISA Standard S71.04.

FBM212FBM212

lf you need to inquire or purchase ,please send the product models to my email or call medirectly .

sunny  He

[Email] sales@xiongbagk.cn

[Mobile] 86-18059884797

[WhatsApp] 86-18059884797

[Skype] sales@saulcontrol.com

FBM212 P0914XL  Differential Thermocouple/mV Input Module

Visual Indicators
LEDs incorporated into the front of the module provide visual status indications.
Easy Removal/Replacement
The module can be removed/replaced without removing field device termination cabling, power, or communication cabling.
Fieldbus Communication
A Fieldbus Communications Module or a Control Processor interfaces to the redundant 2 Mbps module Fieldbus used by the FBMs. The FBM212 accepts communication from either path (A or B) of the 2 Mbps Fieldbus. If one path is unsuccessful or is switched at the system level, the module continues communication over the active path.
Modular Baseplate Mounting
The module mounts on a 200 Series baseplate, which accommodates up to four or eight FBMs. The Modular Baseplate is either DIN rail mounted or rack mounted, and includes signal connectors for redundant Fieldbus, redundant independent DC power, and termination cables. For applications that require CE certification, the baseplate and power supplies must be installed in a metal rack. Open wall mounting in that case is not allowed.
Termination Assemblies
Field I/O signals connect to the FBM subsystem via DIN rail mounted TAs. The TAs used with the FBM212 are described in Termination Assemblies and Cables, page 10.