Sale!

3500/22M 288055-01 Transient Data Interface Module

The 3500/22M Transient Data interface (TDl) is the interfacebetween the 3500 monitoring system and compatiblesoftware(System iCondition Monitoring and Diagnosticsoftware and 3500 system Configuration software). The TDlcombines the function of a 3500/20 Rack interface Module(RlM) with the data collection capability of a communicationprocessor such as TDXnet.
The TDl resides in the slot adjacent to the power supplies of a3500 rack.lt interfaces with M series monitors(3500/40M,3500/42M,etc.)to continuously collect steady state andtransient dynamic (waveform) data and pass this datathrough an Ethernet link to the host software. Refer to theCompatibility section at the end of this document for moreinformation.

Categories: ,

Description

Overview


Essential details:3500/22M 288055-01 Transient Data Interface Module

The 3500/22M Transient Data interface (TDl) is the interfacebetween the 3500 monitoring system and compatiblesoftware(System iCondition Monitoring and Diagnosticsoftware and 3500 system Configuration software). The TDlcombines the function of a 3500/20 Rack interface Module(RlM) with the data collection capability of a communicationprocessor such as TDXnet.
The TDl resides in the slot adjacent to the power supplies of a3500 rack.lt interfaces with M series monitors(3500/40M,3500/42M,etc.)to continuously collect steady state andtransient dynamic (waveform) data and pass this datathrough an Ethernet link to the host software. Refer to theCompatibility section at the end of this document for moreinformation.
Static data capture capability is standard with the TDl.However, using an optional Channel Enabling Disk will allowthe TDl to capture dynamic and high-resolution transientdata as well. The TDl incorporates the communicationprocessor function within the 3500 rack.
Although the TDl provides certain functions common to theentire rack, it is not part of the critical monitoring path andhas no effect on the proper,normal operation of the overalmonitor system for automatic machinery protection. Every3500 rack requires one TDl or RlM, which always occupiesSlot 1 (next to the power supplies).

3500/22M-01-01-01

lf you need to inquire or purchase ,please send the product models to my email or call medirectly .

sunny  He

[Email] sales@xiongbagk.cn

[Mobile] 86-18059884797

[WhatsApp] 86-18059884797

[Skype] sales@saulcontrol.com

3500/22M 288055-01 Transient Data Interface Module

Startup/Coastdown Data
Data collected at selected increments ofspeed and timeIncreasing and decreasing speed intervalsare independently programmableInitiation of transient data collectionbased on detecting the machine speedwithin one of two programmablewindowsThe number of transient events that canbe collected is only limited by theavailable memory in the module
Alarm Data Collection
Pre-and post-alarm data
Static values collected at one secondintervals for 10 minutes before the eventand 1 minute after the eventStatic values collected at 100 ms intervalsfor 20 seconds before the event and 10seconds after the event
2.5 minutes of waveform data collected at10-second intervals before the alarm and1 minute of waveform data collected at10-second intervals after the alarm
Static Values Data
TDl will collect the static values includingthe values measured by the monitors.TDl provides four nX static values for eachpoint.Amplitude and phase are returnedfor each of the values.