RET670 1MRK002246-BD  Transformer protection RET670 ANSI

RET670 provides fast and selective protection, monitoring andcontrol for two-and three-winding transformers.
autotransformers, generator-transformer units, phase shiftingtransformers, special railway transformers and shunt reactorsThe transformer lED is designed to operate correctly over awide frequency range in order to accommodate power systemfrequency variations during disturbances and generator start-upand shut-down.
A very fast differential protection function with settable CT ratiomatching and phase shift compensation makes this lED theideal solution even for the most demanding applications.

Categories: ,

Description

Overview


Essential details:RET670 1MRK002246-BD  Transformer protection RET670 ANSI

RET670 provides fast and selective protection, monitoring andcontrol for two-and three-winding transformers.
autotransformers, generator-transformer units, phase shiftingtransformers, special railway transformers and shunt reactorsThe transformer lED is designed to operate correctly over awide frequency range in order to accommodate power systemfrequency variations during disturbances and generator start-upand shut-down.
A very fast differential protection function with settable CT ratiomatching and phase shift compensation makes this lED theideal solution even for the most demanding applications. SinceRET670 has very low requirements on the main Cls, nointerposing CTs are required.lt is suitable for differentialapplications with multi-breaker arrangements with up to sixrestraint CT inputs. The differential protection function isprovided with 2nd harmonic and wave-block restraint featuresto avoid tripping for magnetizing inrush current, and 5thnarmonic restraint to avoid tripping for overexcitation.
The differential function offers a high sensitivity for low-levelinternal faults, The unique and innovative sensitive differentiaprotection feature of the RET670 provides the best possiblecoverage for winding internal turn-to-turn faults, based on thetheory of symmetrical components
A low impedance restricted ground-fault protection function isavailable as a complimentary sensitive and fast main protectionagainst winding ground faults. This function includes adirectional zero-sequence current criterion for additional
security
Additionally a hiah impedance differential function is available. ltcan be used as restricted ground fault or, as three functions areincluded, also as differential protection on autotransformers. asdifferential protection for a tertiary connected reactor, as T.differential protection for the transformer feeder in a mesh.corner or ring arrangement, as tertiary bus protection and so on
Tripping from pressure relief/Buchholz and temperature devicescan be done through the transformer lED where pulsing, lock-out contact output and so on, is performed. The binary inputsare heavily stabilized against disturbance to prevent incorrectoperations at for example dc system capacitive discharges orDC ground faults.

RET670 1MRK004816-AC

lf you need to inquire or purchase ,please send the product models to my email or call medirectly .

sunny  He

[Email] sales@xiongbagk.cn

[Mobile] 86-18059884797

[WhatsApp] 86-18059884797

[Skype] sales@saulcontrol.com

369-HI-R-M-0-0-0-E  369 Series of Motor Management Relays

The binary inputs are heavily stabilized against disturbances toprevent incorrect operations during for example during DCsystem capacitive discharges or DC ground faults.
Distance protection functionality for phase-to-phase and/orphase-to-ground faults is available as back-up protection forfaults within the transformer and in the connected powersystem.
Versatile phase, ground, positive, negative and zero sequenceovercurrent functions, which can optionally be made directionaland/or voltage controlled, provide further alternative backupprotection. Thermal overload with two time-constants, volts perhertz, over/under voltage and over/under frequency protectionfunctions are also available.
A built-in disturbance and event recorder provides valuable datato the user about status and operation for post-faultdisturbance analysis.
Breaker failure protection for each transformer breaker allowshigh speed back-up tripping of surrounding breakers.
The transformer lED can also be provided with a full control andinterlocking functionality including Synchrocheck function toallow integration of the main and/or a local back-up control
Out of Step function is available to separate power systemsections close to electrical centre at occurring out of step
The advanced logic capability, where user logic is prepared witha graphical tool, allows special applications such as automaticopening of disconnectors in multi-breaker arrangements,closing of breaker rings, load transfer logic and so on. Thegraphical configuration tool ensures simple and fast testing andcommissioning.
Serial data communication is via optical connections to ensureimmunity against disturbances.
The wide application flexibility makes this product an excellentchoice for both new installations and the refurbishment ofexisting installations.