3500/60-01-R0 163179-01 3500/60 & /61 Temperature Monitors  

The 3500/60 & 61 modules provide six channels of temperature monitoring andaccept both Resistance Temperature Detector (RTD) and Thermocouple (TC)temperature inputs. The modules condition these inputs ond compore themagainst user-programmable alarm setpoints. The 3500/60 and 3500/61 provideidentical functionality except that the 3500/61 provides recorder outputs foreach of its six channels while the 3500/60 does not.

Categories: ,

Description

Overview


Essential details:3500/60-01-R0 163179-01 3500/60 & /61 Temperature Monitors  

The 3500/60 & 61 modules provide six channels of temperature monitoring andaccept both Resistance Temperature Detector (RTD) and Thermocouple (TC)temperature inputs. The modules condition these inputs ond compore themagainst user-programmable alarm setpoints. The 3500/60 and 3500/61 provideidentical functionality except that the 3500/61 provides recorder outputs foreach of its six channels while the 3500/60 does not.
The user programs the modules to perform either RTD or TC temperaturemeasurements using the 3500 Rack Configuration Software. Different 1/0modules are availoble in RTD/TC non-isolated or TC isolated versions. The usercan configure the RTD/TC non-isolated version to accept either TC or RTD, or amixture of TC and RTD inputs. The TC isolated version provides 250 Vdc ofchannel-to-channel isolation to protect against external interference.
When used in a Triple Modular Redundant (TMR) configuration, temperaturemonitors must be installed adjacent to each other in groups of three. When usedin this confiquration, the system employs two types of voting to ensure accurateoperation and to avoid single-point failures.

3500/91-01-01

lf you need to inquire or purchase ,please send the product models to my email or call medirectly .

sunny  He

[Email] sales@xiongbagk.cn

[Mobile] 86-18059884797

[WhatsApp] 86-18059884797

[Skype] sales@saulcontrol.com

3500/60-01-R0 163179-01 3500/60 & /61 Temperature Monitors

Features:
  • (6) Channels of Temperature Monitoring
  • Ttemperature Inputs: Resistance Temperature Detector (RTD) and Thermocouple (TC)
  • Recorder Outputs for each Channel (3500/61)
  • RTD/TC Non-Isolated or TC Isolated Versions

The Bently Nevada 3500/60 and 3500/61 Series Temperature Monitors Modules provide six channels of temperature monitoring and accept both Resistance Temperature Detector (RTD) and Thermocouple (TC) temperature inputs. The modules condition these inputs and compare them against user-programmable alarm setpoints. The 3500/60 and 3500/61 provide identical functionality except that the 3500/61 provides recorder outputs for each of its six channels while the 3500/60 does not.

The user programs the modules to perform either RTD or TC temperature measurements using the 3500 Rack Configuration Software. Different I/O modules are available in RTD/TC non-isolated or TC isolated versions. The user can configure the RTD/TC non-isolated version to accept either TC or RTD, or a mixture of TC and RTD inputs. The TC isolated version provides 250 Vdc of channel-to-channel isolation to protect against external interference.

When used in a Triple Modular Redundant (TMR) configuration, temperature monitors must be installed adjacent to each other in groups of three. When used in this configuration, the system employs two types of voting to ensure accurate operation and to avoid single-point failures.