Sale!

REF615A_1G HAFNAEFCBGC1BQK11G Feeder Protection and Control

1.Description
REF615 is a dedicated feeder lED (intelligentelectronic device) designed for the protection.control, measurement and supervision of utilitysubstations and industrial power systemsincluding radial, looped and meshed distributionnetworks with or without distributed powergeneration. REF615 is a member of ABB’sRelion® product family and part of its 615protection and control product series. The 615series lEDs are characterized by theircompactness and withdrawable-unit design.

Categories: ,

Description

Overview


Essential details:REF615A_1G HAFNAEFCBGC1BQK11G Feeder Protection and Control

1.Description
REF615 is a dedicated feeder lED (intelligentelectronic device) designed for the protection.control, measurement and supervision of utilitysubstations and industrial power systemsincluding radial, looped and meshed distributionnetworks with or without distributed powergeneration. REF615 is a member of ABB’sRelion® product family and part of its 615protection and control product series. The 615series lEDs are characterized by theircompactness and withdrawable-unit design.
Re-engineered from the ground up, the 615 serieshas been designed to unleash the full potential ofthe lEC 61850 standard for communication andinteroperability between substation automationdevices.
The lED provides main protection for overheadlines and cable feeders in distribution networks.The lED is also used as back-up protection inapplications, where an independent andredundant protection system is required.
Depending on the chosen standard configurationthe lED is adapted for the protection of overhead line and cable feeders in isolated neutral,resistance earthed, compensated and solidlyearthed networks. Once the standardconfiguration lED has been given the application-specific settings, it can directly be put into service.
The 615 series lEDs support a range ofcommunication protocols including lEC 61850with GOOSE messaging, lEC 60870-5-103,Modbuse and DNP3.
2.Standard configurations

REF615 is available in nine alterative standardconfigurations. The standard signal configurationcan be altered by means of the graphical signalmatrix or the graphical application functionality ofthe Protection and Control lED Manager PCM600.Further, the application configuration functionalityof PCM600 supports the creation of multi-layerlogic functions using various logical elements,including timers and flip-flops. By combiningprotection functions with logic function blocks,the lED configuration can be adapted to user-specific application requirements.

REF615A_1G
HAFNAEFCBGC1BQK11G

lf you need to inquire or purchase ,please send the product models to my email or call medirectly .

sunny  He

[Email] sales@xiongbagk.cn

[Mobile] 86-18059884797

[WhatsApp] 86-18059884797

[Skype] sales@saulcontrol.com

REF615A_1G HAFNAEFCBGC1BQK11G Feeder Protection and Control

Product Description

3. Protection functions

The lED offers directional and non-directionalovercurrent and thermal overload protection aswell as directional and non-directional earth-faultprotection. Some standard configurations allowas an option admiltance-based, harmonics-basedor wattmetric-based earth-fault protection to beused in addition to directional earth-faultprotection, Further, the lED features sensitiveearth-fault protection, phase discontinuityprotection, transient/intermittent earth-faultprotection, overvoltage and undervoltageprotection, residual overvoltage protection,positive-sequence undervoltage and negative.sequence overvoltage protection. Frequencyprotection, including overfrequency, underfrequency and frequency rate-of-changeprotection, is offered in lEDs with standardconfigurations H and J. The lED also incorporatesoptional three-pole multi-shot auto-reclosefunctions for overhead line feeders.
Enhanced with optional hardware and software,the lED also features three light detectionchannels for arc fault protection of the circuitbreaker,busbar and cable compartment of metal-enclosed indoor switchgear.
The arc-fault protection sensor interface isavailable on the optional communication module.Fast tripping increases staff safety and securityand limits material damage in an arc fault situation.

4. Application
The feeder protection lED REF615 can besupplied either with directional or non-directionalearth-fault protection. Directional earth-faultprotection is mainly used in isolated neutral orcompensated networks,whereas non-directionalearth-fault protection is intended for directly orlow impedance earthed neutral networks. The lEDcan also be used for protection of ring-type andmeshed distribution networks as well of radialnetworks containing distributed power generation.
The standard configurations A and B offerdirectional earth-fault protection, if the outgoingfeeder is equipped with phase current
transformers, a core-balance current transformeland residual voltage measurement. The residualcurrent calculated from the phase currents can beused for double (cross country) earth-fault
protection. The lED further features transient/intermittent earth-fault protection. The standardconfigurations C and D offer non-directional earth.fault protection for outgoing feeders equippedwith phase current transformers. The residualcurrent for the earth-fault protection is derivedfrom the phase currents. When applicable, thecore-balance current transformers can be usedfor measuring the residual current, especiallywhen sensitive earth-fault protection is requiredThe standard configurations E and F offer directional earth-fault protection with phase voltage and residual voltage measurement.
Furthermore,the two standard configurations Eand Finclude current circuit supervision and fusefailure supervision for incoming feeders providedwith busbar voltage measurement. In addition tothe functionality of standard configuration E, thestandard configuration F offers directional overcurrent protection, overvoltage and undervoltage protection, positive-sequence undervoltage and negative-sequence overvoltage protection and residual voltage protection.