Sale!

REM610C55HCNR Feeder protection measurement and control device

The REF615 is a feeder protection measurement and control device that can be used for utility substation Protection, control, measurement and monitoring of station and industrial distribution systems, including having or Radial, ring and grid distribution networks without distributed power sources. REF615 It is a member of the 615 Protection Measurement and Control device family in the ABB Relion® product family.
The 615 series devices are compact and easy to disassemble.
The 615 series protection measurement and control devices are newly developed and designed based on IEC 61850 standard It supports interoperation and horizontal communication between automation equipment in the substation.

Categories: ,

Description

Overview


Essential details:REM610C55HCNR Feeder protection measurement and control device

The REF615 is a feeder protection measurement and control device that can be used for utility substation Protection, control, measurement and monitoring of station and industrial distribution systems, including having or Radial, ring and grid distribution networks without distributed power sources. REF615 It is a member of the 615 Protection Measurement and Control device family in the ABB Relion® product family.
The 615 series devices are compact and easy to disassemble.
The 615 series protection measurement and control devices are newly developed and designed based on IEC 61850 standard It supports interoperation and horizontal communication between automation equipment in the substation.
The device can be used as the main protection of overhead lines and feeder lines in distribution network. You can also ask for independence Or require redundancy in the protection system used as backup protection.
Available in a variety of standard configurations, the series can be used to protect neutral points from grounding, Resistance grounding, compensatory grounding and direct grounding of overhead lines and feeders in networks.
Just set it up for your specific application and it’s ready to go. The 615 series devices support multiple communication protocols, including IEC 61850 version 2, based on
IEC 61850-9-2 LE Process Bus, IEC 60870-5-103, Modbus®. Through the SPA-ZC 302 protocol converter, Profibus DVP1 communication can be supported.

REF610C11HCNN

lf you need to inquire or purchase ,please send the product models to my email or call medirectly .

sunny  He

[Email] sales@xiongbagk.cn

[Mobile] 86-18059884797

[WhatsApp] 86-18059884797

[Skype] sales@saulcontrol.com

REM610C55HCNR Feeder protection measurement and control device

Product Description

The REF615 comes in five optional standard configurations. Standard signal configurations are available through protection and
The signal matrix or graphical configuration function of the measurement and control device management tool PCM600 is advanced Modify the row. In addition, the application configuration function in the PCM600 enables the creation of multi-layer logos
A variety of different logic components can be used, including timers and triggers.
Combining the protection function with the logic function module, the configuration can meet the user’s different requirements Application requirements.
The factory device adopts the switching quantity input, switching quantity output, as described in the following function diagram. Default connections between functions and warning lights. Additional features supported in REF615 Must first be added via the application configuration tool and then available in the Signal Matrix tool and install Find it in the center. The direction protection function takes the pointing line as the positive direction.