C7061A1020-ST001 Dynamic Self-Check Ultraviolet Flame Detector

 Solid-state electronic UV flame sensor to detect ultraviolet radiation emitted by the combustion of most carbon-containing fuels such as natural gas, LP gases, and oil.Used with Honeywell burner controls to provide flame supervision in continuous operation for industrial burner applications.

Approvals:

  • CE approved according to EN 298 only when used with the correct Honeywell flame amplifiers and/or burner controls
  • C7061-series models are approved for use in continuous operation, by using dynamic self-check
  • C7061F1 models are ATEX approved for use in explosion hazardous locations; II G Ex d IIC T6, zone 1&2
  • C7061F2 models are UL listed for use in explosion hazardous locations; Class 1, groups C and D; and Class 2, groups E, F, and G
Categories: ,

Description

Overview


Essential details:C7061A1020-ST001 Dynamic Self-Check Ultraviolet Flame Detector

 Solid-state electronic UV flame sensor to detect ultraviolet radiation emitted by the combustion of most carbon-containing fuels such as natural gas, LP gases, and oil.Used with Honeywell burner controls to provide flame supervision in continuous operation for industrial burner applications.

Approvals:

  • CE approved according to EN 298 only when used with the correct Honeywell flame amplifiers and/or burner controls
  • C7061-series models are approved for use in continuous operation, by using dynamic self-check
  • C7061F1 models are ATEX approved for use in explosion hazardous locations; II G Ex d IIC T6, zone 1&2
  • C7061F2 models are UL listed for use in explosion hazardous locations; Class 1, groups C and D; and Class 2, groups E, F, and G

The C7061A1020 and C7061F1003 detector models are identical except for housings.
Model C7061F1003 detector is for use in installations requiring explosion-proof packaging. The housing is conforming the EExd IIC T6 classification. More details for the explosion proof housing can be found in the chapter Standards and Approvals.
The C7061F1003 model has a 1-inch NPT tapping for mounting onto a sight pipe. For allowable mounting positions of model C7061A1020 and model C7061F1003, see Page 9.
The terminal block on both models is of wire clamp type with removable screws and is situated in the compartment of the C7061. The UV cell contains an ultraviolet sensing tube, shutter assembly, terminal block and magnifying lens.
The UV sensor can be mounted from the flame safeguard device up to an average length of ca. 30m. This also depends on the flame signal strength that is measured on the flame safeguard device (min. 2Vdc for SLATE and 1.25Vdc for 7800-series). A cable that is chosen too long weakens the flame signal and may cause nuisance flame failures, resulting into a safety shutdown of the burner.
Using a shielded cable (only connect to ground on controller side, i.e., terminal G) always helps to reduce noise. Avoid running flame sensor cables in parallel with “noisy” cables, like power supply cables or ignition

C7061A1020-ST001

lf you need to inquire or purchase ,please send the product models to my email or call medirectly .

sunny  He

[Email] sales@xiongbagk.cn

[Mobile] 86-18059884797

[WhatsApp] 86-18059884797

[Skype] sales@saulcontrol.com

C7061A1020-ST001 Dynamic Self-Check Ultraviolet Flame Detector

Oscillating shutter interrupts ultraviolet radiation reaching the UV Sensor 12 times per minute (when used with R7861 amplifier in combination with 7800 SERIES) to provide the UV Sensor tube checking function. Amplifier circuitry components are checked from the microprocessor in the 7800 SERIES Control.
• Two flame detectors can be wired in parallel to reduce nuisance shutdowns in difficult flame sighting applications.
A swivel mount is available to facilitate flame sighting -40°C (-40°F) rated ultraviolet sensing tube is available.
Incorporates UV Sensor tube checking feature; used with R7861 and SLATE Dynamic Self-Check amplifiers. High pressure 50 psi (345 kPa) quartz viewing window, magnifying lens and antivibration mount are available as accessories.
Housing meets IP67 enclosure standards. C7061F1003 only: explosion-proof housing, meets EExd IIC T6 classification.
Protective heat block built into mounting flange.
• Detectors can be mounted horizontally, vertically or at any angle in between. The self-checking C7061 models require faceplate alignment and have integral locating reference points to assure proper operation of the shutter mechanism.
Ultraviolet radiation sensing tube and quartz viewing window are field replaceable.