Description
Overview
Essential details:8C-TCNTA1 Series 8 Controller and I/O
Product Description
Honeywell’s C300 Controller provides powerful and robust control for the distributed control system (DCS).
The C300 is a node in operating Honeywell’s field-proven deterministic Control Execution Environment (CEE) core software. The CEE software provides a superior control execution and scheduling environment. Control strategies for each controller node are configured and loaded through a common Control Builder, an easy and intuitive engineering tool.
In addition to a standard and robust library of pre-built function blocks and algorithms, the C300 Controller also supports Custom Algorithm Blocks (CABs). Custom Algorithm Blocks are similar in purpose and structure to the standard function blocks that are distributed with Control Builder. However, CABs have user-defined algorithms and data structures, allowing custom tailored strategies to be developed to specific requirements.
The C300 controller shares its hardware design with the Series 8 I/O, offering an innovative design that reduces footprint and installation and maintenance costs. The C300 controller module is mounted on the C300 Input Output Termination Assembly (IOTA). The C300 IOTA contains only passive devices such as FTE address switches. Figure 1 below depicts the IOTA components.
Product parameter
This document provides technical information to configure the Series 8 I/O. The following Series 8 I/O items are included in this document.
• TC/RTD
• Analog Input – Single Ended
• Analog Input with HART – Single Ended
• Analog Input with HART – Differential
• Analog Output
• Analog Output with HART
• Digital Input Sequence of Events (SOE)
• Digital Input, 24 VDC
• Digital Input Pulse Accumulation
• Digital Output, 24 VDC
• DO Relay Extension Board
APPLICATION
Definitions
• Input Output Termination Assembly (IOTA): An assembly that holds the IOM and the connections for field wiring;
• Input Output Module (IOM): A device that contains most of the electronics required to perform a specific I/O function. The IOM plugs onto the IOTA.
Features
All Series 8 components feature an innovative design that supports enhanced heat management. This unique look provides significant reduction in overall size for the equivalent function.
The unique features of Series 8 I/O include:
• I/O Module and field terminations are combined in the same area. The I/O Module is plugged into the IOTA to eliminate the need for a separate chassis to hold the electronics assemblies
• Two level “detachable” terminals for landing the field wiring in the enclosure, providing easier plant installation and maintenance.
• Field power is supplied through the IOTA, with no need for extra power supplies to power the field devices and the associated craft wired marshalling
• Redundancy is accomplished directly on the IOTA without any external cabling or redundancy control devices, by simply adding a second IOM to an IOTA
• For both IOM and IOTA, coated (module numbers starting with 8C) and uncoated (module numbers starting with 8U) options are provided. Conformal coating material is applied to electronic circuitry to act as protection against moisture, dust, chemicals, and temperature extremes. Coated IOM and IOTA are recommended when electronics must withstand harsh environments and added protection is necessary.
lf you need to inquire or purchase ,please send the product models to my email or call medirectly .
My company under the Sales and Marketing Department, technical engineering Department, after-sales service department, the department of comprehensive management. We can help your business with good service.
1. Sales Department 24/7 service. Handles your requests for any PLC DCS products in a timely manner with patience and professionalism.
2. The engineering department ensures that the products have no quality problems. All products will be inspected before shipping.
3. The financial department checks the payment and refund in time.
4. The warehouse department will carefully check the list of goods, carefully pack them, and deliver the goods in time.
5. After-sales Service Department has a full-time after-sales service team, subordinate to the sales department, and users can timely respond to service requests.
Superiority products 8C-TCNTA1 Series 8 Controller and I/O
PFCL201CE ABB Pressure sensor controller | KJ2231X1-EA1 4-20 mA Series 2 Card EMERSON |
MTL BPHM64 Eaton Safety grid base plate | 330106-0530-10-02-05 Proximity Probes Bently Nevada |
1794-IF4IXT Allen Bradley Flex I/O 1794 series input module | Max-4/11/03/032/99/1/1/00 SERVO MOTOR ELAU |
1734-IM4 Allen Bradley POINT I/O 4 Point Digital Input Module | 330104-00-08-90-02-05 Proximity Probes Bently Nevada |
1769-ECR Allen-Bradley Right end cover (ECR) module used together | D201139L Metso RT node PC AP31 D200137 personality module |
136188-02 Bently Nevada Ethernet /RS232 Modbus I/O module | D201376 Metso RT node PC AP31 D200137 personality module |
AI02J ABB Analog input module | IS220PRTDH1A 336A4940CSP6 Resistance Temperature Device (RTD) Input Module GE |
DSSA165 ABB Ac power module | IS220PSCAH1A 336A4940CSP9 Mark VI component GE |
PXIe-1073 NI PXI Chassis | IS220PDIAH1BE 336A5026ADP4 Resistance Temperature Device (RTD) Input Module GE |
F860-CA HONEYWELL Series C “fieldbus interface module | IS420ESWBH3AX GE Analog I/O modules |
DSSA165 ABB Ac power module | 516TX 336A4940DNP516TX GE 516TX-A Industrial Ethernet Switch |
125840-02 Bently Power module | 128277-01 Future Expansion Faceplate Bently Nevada |
125680-01 BENTLY Displacement detection module | A413139 PC BOARD CIRCUIT BOARD MODULE ASSEMBLY METSO |
147663-01 BENTLY Communication analog output module | D201471 Metso RT node PC AP31 D200137 personality module |
125800-01 Bently Nevada Key phase input/output module | A413188 PC BOARD CIRCUIT BOARD MODULE ASSEMBLY METSO |
140471-01 Bently Nevada Developed I/O module with internal terminal | A413331 PC BOARD CIRCUIT BOARD MODULE ASSEMBLY METSO |
3500/22M 138607-01 Bently Detector module | D201466 Metso RT node PC AP31 D200137 personality module |
3500/94 145988-01 BENTLY Display module | 85UVF1A-1QD Fireye Integrated Flame Scanner with Internal Flame Relay |
3500/42M 176449-02 bently nevada Shaft vibration module | 516TX 336A4940DNP516TX GE A microprocessor device |
3500/92 136180-01 bently nevada Communication gateway module | 516TX-336A4940DNP516TX GE microcontroller |
136180-01 Bently Nevada Communication gateway module | 2MLR-CPUHT HONEYWELL CPU HT bus function |
3500/92-03-01-00 Bently Nevada 3500/92-03-01-00 | 177313-01-01 BENTLY NEVATA Vibration monitoring module |
7264 ABB The four-channel SSI interface module features automatic | PXIE-6556 NI Automatic industrial control module |
MDB-8E SARTORIUS Load cell | PFCL201CE ABB Pressure sensor controller |
3500/15 127610-01 Bently Nevada Digital input module | MTL BPHM64 Eaton Safety grid base plate |