IC670ALG230 Current Source Analog Input Module

The 250 ohm resistor converts input current to a voltage with respect to common. The input R–C filters high-frequency noise, while the opamp buffers the signal to the analog/digital converter. All eight +24 VDC Out terminals are common to each other. The chassis ground  to the I/O Terminal Block ground terminal.

The input signals share a single signal common return. For good noise immunity, establish system signal commons, power supply reference points, and grounds close to such single-ended points. Signal common (as defined by most Standards) for the input module is the negative side of the 24 volt supply. The module’s chassis ground goes to the I/O Terminal Block ground terminal. To improve noise immunity, connect this to the enclosure chassis with a short length of wire.

Categories: ,

Description

Overview


Essential details:IC670ALG230 Current Source Analog Input Module

Product Description

The 250 ohm resistor converts input current to a voltage with respect to common. The input R–C filters high-frequency noise, while the opamp buffers the signal to the analog/digital converter. All eight +24 VDC Out terminals are common to each other. The chassis ground  to the I/O Terminal Block ground terminal.

The input signals share a single signal common return. For good noise immunity, establish system signal commons, power supply reference points, and grounds close to such single-ended points. Signal common (as defined by most Standards) for the input module is the negative side of the 24 volt supply. The module’s chassis ground goes to the I/O Terminal Block ground terminal. To improve noise immunity, connect this to the enclosure chassis with a short length of wire.
Two wire loop powered transmitters (type 2) should have isolated or ungrounded sensor inputs. Loop powered devices should use the same power supply as the input module. If a different supply must be used, connect the signal common to the module common. Also, ground only one point on the signal common, preferrably at the input module. If the power supply is not grounded, the entire analog network is at a floating potential (except for the cable shields). Thus this circuit can be isolated if it has a separate isolated supply.
If shielded wire is used to reduce noise pickup, the shield drain wires should have a separate path to ground from any loop power supply ground to avoid inducing noise due to drain current.
Three wire transmitters require a third wire to provide power. The shield may be used as the power supply return. If the system is isolated, a third wire (triad cable) should be used instead of the shield for the power, and the shields grounded.
A separate, remote power supply can also be used. A floating supply should be used for best results. Grounding both supplies creates a ground loop. The circuit may still work despite this, however achieving good results requires very good voltage compliance of the transmitter.

IC670ALG230

Product parameter

The Current-Source Analog Input Module converts current levels to unscaled analog input data. Analog scaling is performed by the Bus Interface Unit, which provides the scaled data to the host. Software Range selections of 0 to 20 mA and 4 to 20 mA are configurable on a per-channel basis.
The default range is 0 to 20 mA. The default scaling for the module is:
Eng Lo = 0
Eng Hi = 20,000
Int Lo = 0
Int Hi = 20,000
The module has 8 words (16 bytes) of analog input data. A Bus Interface Unit is required to provide this input data to the host and/or local processor.

APPLICATION

Isolated 4 wire transmitters can avoid ground loop problems with remotely powered sensors.
If the module is installed on an I/O Terminal Block with Box Terminals or an I/O Terminal Block with Barrier Terminals, an Auxiliary Terminal Block must be used to provide additional wiring terminals. For the I/O Terminal Block with Wire to Board Connectors, external connection points are usually preferred, although an Auxiliary Terminal Block can be used.
Auxiliary Terminal Blocks have all terminals connected together internally. The Auxiliary Terminal Block with box terminals has 13 terminals, each of which accommodates one AWG # 14 (avg 2.1mm2 cross section) to AWG #22 (avg 0.36mm2 cross section) wire, or two wires up to AWG #18 (avg. 0.86mm2 cross section). The Auxiliary Terminal Block with barrier terminals has nine terminals, each of which can accommodate one or two wires up to AWG #14 (avg 2.1mm2 cross section).
For 3-wire and 4-wire transmitters, an I/O Terminal Block with box terminals and Auxiliary I/O Terminal Block can be used without any additional terminal strip. An additional terminal strip is needed for an I/O Terminal Block with barrier terminals and an Auxiliary Terminal Block.
The +24V Out terminals are a common fused output from DC+ to drive loop–powered 2 wire sensors. For anything other than 2-wire transmitters, jumper the Auxiliary Terminal Block to DC–.

lf you need to inquire or purchase ,please send the product models to my email or call medirectly .

My company under the Sales and Marketing Department, technical engineering Department, after-sales service department, the department of comprehensive management. We can help your business with good service.

1. Sales Department 24/7 service. Handles your requests for any PLC DCS products in a timely manner with patience and professionalism.

2. The engineering department ensures that the products have no quality problems. All products will be inspected before shipping.

3. The financial department checks the payment and refund in time.

4. The warehouse department will carefully check the list of goods, carefully pack them, and deliver the goods in time.

5. After-sales Service Department has a full-time after-sales service team, subordinate to the sales department, and users can timely respond to service requests.

Shipping

Superiority products 330105-02-12-10-02-00 8 MM REVERSE MOUNT PROBE

PFCL201CE   ABB   Pressure sensor controller KJ2231X1-EA1  4-20 mA Series 2 Card  EMERSON
MTL BPHM64  Eaton  Safety grid base plate 330106-0530-10-02-05  Proximity Probes  Bently Nevada
1794-IF4IXT  Allen Bradley  Flex I/O 1794 series input module Max-4/11/03/032/99/1/1/00  SERVO MOTOR  ELAU
1734-IM4 Allen Bradley POINT I/O 4 Point Digital Input Module 330104-00-08-90-02-05   Proximity Probes  Bently Nevada
1769-ECR Allen-Bradley  Right end cover (ECR) module used together D201139L  Metso RT node PC AP31 D200137  personality module
136188-02 Bently Nevada  Ethernet /RS232 Modbus I/O module D201376  Metso RT node PC AP31 D200137  personality module
AI02J  ABB   Analog input module IS220PRTDH1A 336A4940CSP6  Resistance Temperature Device (RTD) Input Module  GE
DSSA165 ABB  Ac power module IS220PSCAH1A 336A4940CSP9   Mark VI component  GE
PXIe-1073  NI  PXI Chassis IS220PDIAH1BE 336A5026ADP4  Resistance Temperature Device (RTD) Input Module  GE
F860-CA  HONEYWELL  Series C “fieldbus interface module IS420ESWBH3AX  GE  Analog I/O modules
DSSA165 ABB  Ac power module 516TX 336A4940DNP516TX  GE  516TX-A Industrial Ethernet Switch
125840-02 Bently Power module 128277-01  Future Expansion Faceplate  Bently Nevada
125680-01 BENTLY  Displacement detection module A413139  PC BOARD CIRCUIT BOARD MODULE ASSEMBLY  METSO
147663-01 BENTLY Communication analog output module D201471 Metso RT node PC AP31 D200137  personality module
125800-01 Bently Nevada Key phase input/output module A413188  PC BOARD CIRCUIT BOARD MODULE ASSEMBLY  METSO
140471-01 Bently Nevada Developed I/O module with internal terminal A413331 PC BOARD CIRCUIT BOARD MODULE ASSEMBLY  METSO
3500/22M 138607-01 Bently  Detector module D201466 Metso RT node PC AP31 D200137  personality module
3500/94 145988-01 BENTLY Display module 85UVF1A-1QD  Fireye  Integrated Flame Scanner with Internal Flame Relay
3500/42M 176449-02 bently nevada Shaft vibration module 516TX 336A4940DNP516TX  GE  A microprocessor device
3500/92 136180-01 bently nevada  Communication gateway module 516TX-336A4940DNP516TX GE  microcontroller
136180-01 Bently Nevada Communication gateway module 2MLR-CPUHT HONEYWELL  CPU HT bus function
3500/92-03-01-00 Bently Nevada 3500/92-03-01-00 177313-01-01 BENTLY NEVATA Vibration monitoring module
7264  ABB The four-channel SSI interface module features automatic PXIE-6556  NI  Automatic industrial control module
MDB-8E  SARTORIUS Load cell PFCL201CE   ABB   Pressure sensor controller
3500/15 127610-01 Bently Nevada  Digital input module MTL BPHM64  Eaton  Safety grid base plate