SPAJ140C SPAJ140C Overcurrent and ground protection device

Functions and Applications:
The SPAJ140C is suitable for radiant feeders in directly grounded, resistance grounded or impedance grounded power systems, providing selective protection against short circuits and ground faults.
It includes two parts: overcurrent element and ground fault element, both of which have highly flexible tripping and signaling devices.
Feeder protection can be used according to the requirements of single-phase, two-phase or three-phase overcurrent protection and directional ground fault protection.
The SPAJ140C also includes circuit breaker failure protection.

Categories: ,

Description

Overview


Essential details:SPAJ140C SPAJ140C Overcurrent and ground protection device

Product Description

Functions and Applications:
The SPAJ140C is suitable for radiant feeders in directly grounded, resistance grounded or impedance grounded power systems, providing selective protection against short circuits and ground faults.
It includes two parts: overcurrent element and ground fault element, both of which have highly flexible tripping and signaling devices.
Feeder protection can be used according to the requirements of single-phase, two-phase or three-phase overcurrent protection and directional ground fault protection.
The SPAJ140C also includes circuit breaker failure protection.
How it works:
The SPAJ140C is a secondary relay that connects to the current transformer of the protected feeder.
The three-phase overcurrent element and the directionless ground fault element continuously measure the phase current and zero sequence current of the protected feeder.
In case of failure, these elements can initiate an external automatic reclosing or trip the circuit breaker according to the selected protection mode.
Operating characteristics:
When the phase current exceeds the setting value of the underset segment I> of the overcurrent element, the element emits a start signal after a preset delay (for example, about 60 ms).
When the setting action time arrives, the overcurrent protection low set action trip command is issued.
The SPAJ140C is designed to allow users to configure tripping and signaling facilities according to application requirements.
Communication and interface:
SPAJ140C supports a variety of communication protocols and interfaces for data exchange and remote control with host computer, PLC and other devices.
Application field:
SPAJ140C is widely used in electric power, construction, office distribution network and other industries, suitable for overhead lines, cable lines, input and outlet cabinets and other scenarios.

SPAJ140C-AA

Product parameter

Rated current range: This includes the rated current range of overcurrent components and ground fault components, 0.1-0.8In (In is rated current).
Operation current and time:
Overcurrent elements have multiple operating current ranges, such as 0.1-10.0In, with different operating time delays.
Ground fault elements typically have a similar operating current range and provide non-directional ground fault protection.
Protection Type: The SPAJ140C provides single-phase, two-phase, or three-phase overcurrent protection and non-directional ground fault protection.
Circuit breaker failure protection: Some models of SPAJ140C include circuit breaker failure protection.
Communication interface: Support a variety of communication protocols and interfaces, such as Modbus, Ethernet, etc., in order to exchange data and remote control with the host computer, PLC and other devices.
Power requirements: This typically includes rated voltage and frequency ranges, as well as power consumption requirements.
Working environment: Specifies the temperature range, humidity requirements, and protection level (such as IP level) of the working environment.

APPLICATION

The SPAJ140C combined overcurrent and ground fault relay is suitable for a variety of power system applications, including:
Power system protection: It is particularly suitable for radiant feeders in directly grounded, resistance grounded or impedance grounded power systems as selective short-circuit and ground fault protection. This relay is capable of identifying the type and location of the fault, and cutting off the fault circuit when the fault occurs to protect the power system from high current grounding, resistance grounding, neutral short circuit and ground fault in the radial feeder grid.
Industrial automation: The SPAJ140C is also suitable for industrial automation systems, providing the necessary protection and control for power equipment and systems.
Building automation: In the construction sector, the SPAJ140C can be used to protect the power system within the building, ensuring the stability and security of the power supply.
Energy management: In an energy management system, the SPAJ140C can be used to monitor and control the flow of electricity, ensuring the efficient use of energy and the stable operation of the system.
In addition, the SPAJ140C is also suitable for user terminal substations (stations) with voltage levels of 10kV and below, as well as scenarios such as overhead lines, cable lines, and incoming and outgoing line cabinets.
Overall, the SPAJ140C is a powerful and flexible relay protection device that can meet the needs of different power systems and application scenarios.

Shipping

Superiority products SPAJ140C SPAJ140C Overcurrent and ground protection device

PFCL201CE   ABB   Pressure sensor controller KJ2231X1-EA1  4-20 mA Series 2 Card  EMERSON
MTL BPHM64  Eaton  Safety grid base plate 330106-0530-10-02-05  Proximity Probes  Bently Nevada
1794-IF4IXT  Allen Bradley  Flex I/O 1794 series input module Max-4/11/03/032/99/1/1/00  SERVO MOTOR  ELAU
1734-IM4 Allen Bradley POINT I/O 4 Point Digital Input Module 330104-00-08-90-02-05   Proximity Probes  Bently Nevada
1769-ECR Allen-Bradley  Right end cover (ECR) module used together D201139L  Metso RT node PC AP31 D200137  personality module
136188-02 Bently Nevada  Ethernet /RS232 Modbus I/O module D201376  Metso RT node PC AP31 D200137  personality module
AI02J  ABB   Analog input module IS220PRTDH1A 336A4940CSP6  Resistance Temperature Device (RTD) Input Module  GE
DSSA165 ABB  Ac power module IS220PSCAH1A 336A4940CSP9   Mark VI component  GE
PXIe-1073  NI  PXI Chassis IS220PDIAH1BE 336A5026ADP4  Resistance Temperature Device (RTD) Input Module  GE
F860-CA  HONEYWELL  Series C “fieldbus interface module IS420ESWBH3AX  GE  Analog I/O modules
DSSA165 ABB  Ac power module 516TX 336A4940DNP516TX  GE  516TX-A Industrial Ethernet Switch
125840-02 Bently Power module 128277-01  Future Expansion Faceplate  Bently Nevada
125680-01 BENTLY  Displacement detection module A413139  PC BOARD CIRCUIT BOARD MODULE ASSEMBLY  METSO
147663-01 BENTLY Communication analog output module D201471 Metso RT node PC AP31 D200137  personality module
125800-01 Bently Nevada Key phase input/output module A413188  PC BOARD CIRCUIT BOARD MODULE ASSEMBLY  METSO
140471-01 Bently Nevada Developed I/O module with internal terminal A413331 PC BOARD CIRCUIT BOARD MODULE ASSEMBLY  METSO
3500/22M 138607-01 Bently  Detector module D201466 Metso RT node PC AP31 D200137  personality module
3500/94 145988-01 BENTLY Display module 85UVF1A-1QD  Fireye  Integrated Flame Scanner with Internal Flame Relay
3500/42M 176449-02 bently nevada Shaft vibration module 516TX 336A4940DNP516TX  GE  A microprocessor device
3500/92 136180-01 bently nevada  Communication gateway module 516TX-336A4940DNP516TX GE  microcontroller
136180-01 Bently Nevada Communication gateway module 2MLR-CPUHT HONEYWELL  CPU HT bus function
3500/92-03-01-00 Bently Nevada 3500/92-03-01-00 177313-01-01 BENTLY NEVATA Vibration monitoring module
7264  ABB The four-channel SSI interface module features automatic PXIE-6556  NI  Automatic industrial control module
MDB-8E  SARTORIUS Load cell PFCL201CE   ABB   Pressure sensor controller
3500/15 127610-01 Bently Nevada  Digital input module MTL BPHM64  Eaton  Safety grid base plate