SCXI-1102C Voltage Input Module SCXI-1104C

The NI SCXI-1102C (Part Number: 776572-02C) module has a three-pole lowpass filter with a 10 kHz cutoff frequency, 32 differential analog input channels, maximum working voltage of ±10 V, and a 20 minute suggested warm-up time. This Voltage Input Module is designed for the signal conditioning of thermocouples, low-bandwidth volt and millivolt sources, 4 to 20 mA current sources, and 0 to 20 mA process-current sources. The NI SCXI-1102C can perform these measurements: current input, thermistors, voltage input, RTD, and thermocouple. It has a power requirement of 15 mA maximum at 5 V, and 150 mA maximum at ±15 V.

Categories: ,

Description

Overview


Essential details:SCXI-1102C Voltage Input Module SCXI-1104C

Product Description

National Instruments SCXI-1102C Voltage Input Module

The NI SCXI-1102C (Part Number: 776572-02C) module has a three-pole lowpass filter with a 10 kHz cutoff frequency, 32 differential analog input channels, maximum working voltage of ±10 V, and a 20 minute suggested warm-up time. This Voltage Input Module is designed for the signal conditioning of thermocouples, low-bandwidth volt and millivolt sources, 4 to 20 mA current sources, and 0 to 20 mA process-current sources. The NI SCXI-1102C can perform these measurements: current input, thermistors, voltage input, RTD, and thermocouple. It has a power requirement of 15 mA maximum at 5 V, and 150 mA maximum at ±15 V.

The gain/input range is a software-configurable setting that enables the user to select the correct amplification to completely utilize the range of the E/M Series DAQ instrument. For many applications, NI-DAQ selects the gain for the user based on the input range. If not, the user can choose the correct gain by utilizing the input signal voltage range and the full-scale limits of the SCXI-1102C output. The user can choose a gain of 1 or 100 per channel.

SCXI-1104C

Product parameter

Model SCXI-1102C
Manufacturer National Instruments
Part Number 776572-02C
Type Voltage Input Module
Channels 32
Cutoff Frequency 10 kHz
Maximum Working Voltage ±10 V
Dimensions 1.2 by 6.8 by 8.0 in.
Weight 24.6 oz.

APPLICATION

When the user is utilizing NI-DAQmx, they can configure software settings, such as sensor type and gain/input signal range in several ways. These include functions in the user’s application and task or global channel using the Measurement & Automation Explorer (MAX) tool. However, it is vital to realize that not all software-configurable settings are configurable both ways. If the user is utilizing the traditional NI-DAQ (Legacy), they can configure software settings (gain/input signal range, etc.) in three ways, including: functions in the user’s ADE, virtual channels properties in MAX, and module property pages in MAX. The device should be calibrated at least once a year. The NI device weighs 24.6 oz, and measures 1.2 x 6.8 x 8.0 in. in physical dimensions. It has a recommended operating temperature range of 0 to 50 °C, a storage temperature range of –20 to 70 °C, and a non-condensing humidity range of 10 to 90% RH.

Shipping

Superiority products SCXI-1102C Voltage Input Module SCXI-1104C

PFCL201CE   ABB   Pressure sensor controller KJ2231X1-EA1  4-20 mA Series 2 Card  EMERSON
MTL BPHM64  Eaton  Safety grid base plate 330106-0530-10-02-05  Proximity Probes  Bently Nevada
1794-IF4IXT  Allen Bradley  Flex I/O 1794 series input module Max-4/11/03/032/99/1/1/00  SERVO MOTOR  ELAU
1734-IM4 Allen Bradley POINT I/O 4 Point Digital Input Module 330104-00-08-90-02-05   Proximity Probes  Bently Nevada
1769-ECR Allen-Bradley  Right end cover (ECR) module used together D201139L  Metso RT node PC AP31 D200137  personality module
136188-02 Bently Nevada  Ethernet /RS232 Modbus I/O module D201376  Metso RT node PC AP31 D200137  personality module
AI02J  ABB   Analog input module IS220PRTDH1A 336A4940CSP6  Resistance Temperature Device (RTD) Input Module  GE
DSSA165 ABB  Ac power module IS220PSCAH1A 336A4940CSP9   Mark VI component  GE
PXIe-1073  NI  PXI Chassis IS220PDIAH1BE 336A5026ADP4  Resistance Temperature Device (RTD) Input Module  GE
F860-CA  HONEYWELL  Series C “fieldbus interface module IS420ESWBH3AX  GE  Analog I/O modules
DSSA165 ABB  Ac power module 516TX 336A4940DNP516TX  GE  516TX-A Industrial Ethernet Switch
125840-02 Bently Power module 128277-01  Future Expansion Faceplate  Bently Nevada
125680-01 BENTLY  Displacement detection module A413139  PC BOARD CIRCUIT BOARD MODULE ASSEMBLY  METSO
147663-01 BENTLY Communication analog output module D201471 Metso RT node PC AP31 D200137  personality module
125800-01 Bently Nevada Key phase input/output module A413188  PC BOARD CIRCUIT BOARD MODULE ASSEMBLY  METSO
140471-01 Bently Nevada Developed I/O module with internal terminal A413331 PC BOARD CIRCUIT BOARD MODULE ASSEMBLY  METSO
3500/22M 138607-01 Bently  Detector module D201466 Metso RT node PC AP31 D200137  personality module
3500/94 145988-01 BENTLY Display module 85UVF1A-1QD  Fireye  Integrated Flame Scanner with Internal Flame Relay
3500/42M 176449-02 bently nevada Shaft vibration module 516TX 336A4940DNP516TX  GE  A microprocessor device
3500/92 136180-01 bently nevada  Communication gateway module 516TX-336A4940DNP516TX GE  microcontroller
136180-01 Bently Nevada Communication gateway module 2MLR-CPUHT HONEYWELL  CPU HT bus function
3500/92-03-01-00 Bently Nevada 3500/92-03-01-00 177313-01-01 BENTLY NEVATA Vibration monitoring module
7264  ABB The four-channel SSI interface module features automatic PXIE-6556  NI  Automatic industrial control module
MDB-8E  SARTORIUS Load cell PFCL201CE   ABB   Pressure sensor controller
3500/15 127610-01 Bently Nevada  Digital input module MTL BPHM64  Eaton  Safety grid base plate