EP160 PROGRAMMER MODULES

The Fireye EP160, EP161 (extended MTFI), EP163 (programmable), EP170 and EP174 (early spark termination), EP165, EP166 (pilot stabilization) or EP177 (early spark termination and programmable operating parameters) programmer modules are used with the FLAME-MONITOR Burner Management Control System (P/N’s E100 and E110). Several operational characteristics of the programmer are determined by six (6) dipswitches located on the side of the programmer. These characteristics include forced blower motor start delay (dipswitch 1), extended purge timing (dipswitches 3, 4, 5) and the option requiring the 3-P running interlock circuit to be proven open at the start of the operating cycle (dipswitch 6). Dipswitch 2 is inactive. Models EP163 and EP177 characteristics are programmed via the ED510 Display Module, rather than by dipswitch.
The EP160, EP161, EP163, EP165, EP166, EP170, EP174 and EP177 programmers provide start-up programming, safe-start check, and flame monitoring supervision. They insure open damper (high purge) prepurge, proof of low fire position, and fuel valve end switch safety checks. A running interlock circuit on the FLAME-MONITOR system constantly monitors the limit switches, air flow switches, and fuel pressure switches through the programmer. The programmer control is designed to initiate a safety lockout if any of these circuits are open at the improper point in the control cycle.

Categories: ,

Description

Overview


Essential details:EP160 PROGRAMMER MODULES

Product Description

The Fireye EP160, EP161 (extended MTFI), EP163 (programmable), EP170 and EP174 (early spark termination), EP165, EP166 (pilot stabilization) or EP177 (early spark termination and programmable operating parameters) programmer modules are used with the FLAME-MONITOR Burner Management Control System (P/N’s E100 and E110). Several operational characteristics of the programmer are determined by six (6) dipswitches located on the side of the programmer. These characteristics include forced blower motor start delay (dipswitch 1), extended purge timing (dipswitches 3, 4, 5) and the option requiring the 3-P running interlock circuit to be proven open at the start of the operating cycle (dipswitch 6). Dipswitch 2 is inactive. Models EP163 and EP177 characteristics are programmed via the ED510 Display Module, rather than by dipswitch.
The EP160, EP161, EP163, EP165, EP166, EP170, EP174 and EP177 programmers provide start-up programming, safe-start check, and flame monitoring supervision. They insure open damper (high purge) prepurge, proof of low fire position, and fuel valve end switch safety checks. A running interlock circuit on the FLAME-MONITOR system constantly monitors the limit switches, air flow switches, and fuel pressure switches through the programmer. The programmer control is designed to initiate a safety lockout if any of these circuits are open at the improper point in the control cycle.
The programmer module will de-energize all fuel valve circuits within four (4) seconds (max.) following a flame failure [two (2) seconds for the EP165 and EP166], or at the end of the pilot trial for ignition period if no flame is detected. An alarm circuit will be energized following a safety lockout.
The programmer module includes an RJ45 style connector to interface with an integral or remote alpha-numeric display (P/N ED510). It is also backward compatible with the ED500 display. It includes two (2) additional RJ style connectors to connect to an E500 communication interface in a multi-drop configuration or allow communication via a Modbus protocol. The programmer will also communicate with the E500 via the ED550 cables to provide backward compatibility.
The programmer is the heart of the FLAME-MONITOR System and features a plug-in design for ease of installation. It is micro-processor based and stores the burner cycles, burner hours, system hours, and lockout history (with burner cycle and burner hour time stamp) which are accessible via the ED510 alpha-numeric display, E500 Communication Interface, InTouch Wireless Monitoring System or Modbus communications. If replaced, the new programmer card will begin accumulating a new history.

EP160

Product parameter

The EP programmer modules are used with the Fireye EB700 and E110 chassis. They are installed in the chassis by inserting the EP programmer module into the second slot on the control. This slot is marked “Programmer Module” on the side of the chassis. Refer to bulletin E-1101 for complete system information.
The programmer module is designed to fit only in the proper slot. It cannot be snapped into place if inserted in the wrong location. DO NOT FORCE THEM.
An amplifier module, display module ED510 (ED500 is obsolete), flame scanner, and wiring base are also required for the FLAME-MONITOR control.
All programmers with an Engineering code of 28 or later (e.g. 9414-28) are compatible with both the ED500 and ED510 display modules. See “Programmer and Display Module Compatibility” later in this document. The Engineering code is located on the back side of the board in the lower right hand corner. The EP163 programmer requires the ED510 display for initial configuration programming.

APPLICATION

MCCZ File MP 1537
Controls, Primary Safety – Listed
MCCZ2 File MP1537
Controls, Primary Safety – Component
MCCZ7 File MP1537
Controls, Primary Safety Certified for Canada
MCCZ8 file MP1537
Controls, Primary Safety Certified for Canada – Component
ACCEPTABLE BY: INDUSTRIAL RISK INSURERS (I.R.I.)
FACTORY MUTUAL (FM) APPROVED

Superiority products EP160 PROGRAMMER MODULES

UFC762AE101 3BHE006412R0101  Main board module IC697CMM742-DC  Series 90-70 Communications Module
87199-01  Stator insulation monitor FC-TSRO-0824  Digital Output Field Termination Assembly
MVME55006E-0161R  VMEbus Single-Board Computer MVC3001-4003A  ALSPA MV3000 Delta Controller
3500/25 149369-01  Keyphasor module 6SM57M-3.000  Synchronous Servomotors
3500/92 136180-01  Keyphasor module 05701-A-0282  Modbus Interface Module Kit RS422/485
1X00416H01  POWER SUPPLY  24V 300W & 25V 500W OUT DIN-RAIL MOUNT 3500/91 190782-01  EGD gateway module
5X00241G02  Ovation Westinghouse  Controller module 05701-A-0361  System 57 MODBUS Interface
489-P5-LO-A20  generator management relay 3500/65 145988-02  16-Channel Temperature Monitor
TRICON  3805E  TRICONEX  Analog Output Modules 3500/65  172103-01 16-Channel Temperature Monitor
5X00226G02  Ovation Westinghouse  Controller module 136188-02 Ethernet/RS485 Modbus I/O Module
MC-4/11/10/400  PowerDrive Motion Controller PCI-6733  Analog Output Device
2MLR-CPUH/T   MasterLogic  Programmable Logic Controller 3ASC25H209  DATX110   I/O board control module
KJ4002X1-BA1  Left 8 Wide Vertical Carrier CE4002S1T2B5  Standard I/O Termination Block
S72402-NANANA  S700  digital servo drive CE4005S2B4  Standard I/O Termination Block
SCYC55830 58063282A  Trigger plate PCI-4462  Sound and Vibration Device
IC697CMM742-DC  Ethernet Interface  Communications Modules TU890 3BSC690075R1  compact MTU for the S800 I/O
PPC322BE1 HIEE300900R1  Industrial drive function module KJ4001X1-BE1 12P0818X072 REV:L  8 Wide I/O Carrier with Shield Bar
VMIVME-3122  High-Performance 16-Bit Analog-to-Digital Converter (ADC) KJ2201X1-JA1  Redundant SLS Terminal Block