Hydran H201Ti Continuous dissolved gas in Oil Analysis (DGA) monitor

The Hydran H201Ti is a small, easy-to-set continuous dissolved gas in Oil analysis (DGA) monitor from GE Grid Solutions. It provides basic fault diagnosis information for the transformer, complies with IEEE® standard C57.104, and acts as an early warning system to help detect fault conditions in advance, thereby minimizing the risk of unplanned outages.
Main features and applications:
Size and installation: The Hydran 201Ti is small and easy to install and can be permanently installed on a single transformer oil valve without the need for additional piping or pumps.
Sensor technology: Using fuel cell technology (described in the standard as a fixed instrument – Method 3), 100% responsive to hydrogen (general fault gas) and sensitive to carbon monoxide (superheated paper), acetylene (arc) and ethylene (superheated oil), covers all major causes of transformer failure.
Categories: ,

Description

Overview


Essential details:Hydran H201Ti Continuous dissolved gas in Oil Analysis (DGA) monitor

Product Description

The Hydran H201Ti is a small, easy-to-set continuous dissolved gas in Oil analysis (DGA) monitor from GE Grid Solutions. It provides basic fault diagnosis information for the transformer, complies with IEEE® standard C57.104, and acts as an early warning system to help detect fault conditions in advance, thereby minimizing the risk of unplanned outages.
Main features and applications:
Size and installation: The Hydran 201Ti is small and easy to install and can be permanently installed on a single transformer oil valve without the need for additional piping or pumps.
Sensor technology: Using fuel cell technology (described in the standard as a fixed instrument – Method 3), 100% responsive to hydrogen (general fault gas) and sensitive to carbon monoxide (superheated paper), acetylene (arc) and ethylene (superheated oil), covers all major causes of transformer failure.
Monitoring capability: Continuous measurement of major H2 failure gases and output of gas ppm values via local LCD display and remote communication.
Alarm configuration: When an abnormal faulty gas level is detected, an alarm is triggered, two alarm levels can be set (warning and alarm), and the alarm can be set based on the gas ppm level or the rate of gas change (hourly or daily).
Communication: A local LCD displays real-time dissolved gas ppm values, providing analog output (4-20mA) and digital output via isolated RS-485, using Modbus or Hydran protocols.
Applications: Suitable for power companies and industry, it provides a simple and effective solution for less critical transformers, reducing the risk of production disruptions due to power failures and minimizing costly downtime

H201TI

Product parameter

Measurement range: 0-2000 ppm (volume/volume, H2 equivalent).
Measurement accuracy: ±10% reading ± 25 ppm (H2 equivalent).
Response time: 10 minutes (90% of change).
Environmental conditions: Operating ambient temperature -40°C to +55°C, relative humidity 0-95% RH (non-condensing), oil temperature at the oil valve -40°C to +105°C, oil pressure 0-700 kpa

APPLICATION

Mark IV Version: The latest version has a complete refurbishment of the electronic board and power supply to RoHS standards, addressing any obsoletions and further improving this time-tested product.
Compatibility: Compatible with GE’s Perception™ Fleet software for download, trend analysis, and data analysis.
Controller options: The 201Ti can be connected to optional controllers in order to communicate with multiple units and create local networks.
The Hydran 201Ti provides a real-time single compound fault gas measurement system with local and remote alarm Settings, as well as the ability to view gas readings and trends remotely via serial port communication, and is easy to install without on-site calibration

Superiority products Hydran H201Ti Continuous dissolved gas in Oil Analysis (DGA) monitor

UFC762AE101 3BHE006412R0101  Main board module IC697CMM742-DC  Series 90-70 Communications Module
87199-01  Stator insulation monitor FC-TSRO-0824  Digital Output Field Termination Assembly
MVME55006E-0161R  VMEbus Single-Board Computer MVC3001-4003A  ALSPA MV3000 Delta Controller
3500/25 149369-01  Keyphasor module 6SM57M-3.000  Synchronous Servomotors
3500/92 136180-01  Keyphasor module 05701-A-0282  Modbus Interface Module Kit RS422/485
1X00416H01  POWER SUPPLY  24V 300W & 25V 500W OUT DIN-RAIL MOUNT 3500/91 190782-01  EGD gateway module
5X00241G02  Ovation Westinghouse  Controller module 05701-A-0361  System 57 MODBUS Interface
489-P5-LO-A20  generator management relay 3500/65 145988-02  16-Channel Temperature Monitor
TRICON  3805E  TRICONEX  Analog Output Modules 3500/65  172103-01 16-Channel Temperature Monitor
5X00226G02  Ovation Westinghouse  Controller module 136188-02 Ethernet/RS485 Modbus I/O Module
MC-4/11/10/400  PowerDrive Motion Controller PCI-6733  Analog Output Device
2MLR-CPUH/T   MasterLogic  Programmable Logic Controller 3ASC25H209  DATX110   I/O board control module
KJ4002X1-BA1  Left 8 Wide Vertical Carrier CE4002S1T2B5  Standard I/O Termination Block
S72402-NANANA  S700  digital servo drive CE4005S2B4  Standard I/O Termination Block
SCYC55830 58063282A  Trigger plate PCI-4462  Sound and Vibration Device
IC697CMM742-DC  Ethernet Interface  Communications Modules TU890 3BSC690075R1  compact MTU for the S800 I/O
PPC322BE1 HIEE300900R1  Industrial drive function module KJ4001X1-BE1 12P0818X072 REV:L  8 Wide I/O Carrier with Shield Bar
VMIVME-3122  High-Performance 16-Bit Analog-to-Digital Converter (ADC) KJ2201X1-JA1  Redundant SLS Terminal Block