Description
Overview
Essential details:3500/92 136188-02 ETHERNET/RS232 MODBUS I/O MODULE BENTLY NEVADA
Products Description
Part Number: 136188-02
Manufacturer: Bently Nevada
Series: 3500
Product Type: Ethernet/RS485 Modbus I/O Module
Availability: In Stock
Country of Origin: USA
136188-02 is an Ethernet/RS232 Modbus I/O Module developed by Bently Nevada. This component includes the Firmware Upgrade Kit (126M4118-01). It is a part of 3500/92 Communication Gateway module. The 3500/92 Communication Gateway module offers extensive serial (RS232/RS422/RS485) and Ethernet TCP/IP communication capabilities for the integration of all rack monitoring values and statuses with process control and other automation systems. Additionally, it enables Ethernet communication with the data acquisition software and 3500 Rack Configuration Software.
Characteristics
Power Consumption
5.6 watts typical with Modbus RS485 I/O Module
Operating Temperature
-30 °C to +65 °C (-22 °F to +149 °F)
Storage Temperature
-40 °C to +85 °C (-40 °F to +185 °F)
Dimensions
(Height x Width x Depth) 241 mm x 24.4 mm x 99.1mm (9.50 in x 0.96 in x 3.90 in)
Weight
0.44 kg (0.96 lb.)
Analog signal, there are two, voltage or current signal, is generally the signal transmitted by the transmitter, such as the pressure transmitter to detect the water pipe pressure, it will output an analog signal 4- 20ma or 0-10V signal to PLC, PLC for data processing.
Switching quantity input point (DI), processing switching quantity input signal.
Analog input point (AI), processing analog input signal (0-20 MADc,0-5VDC).
Resistance signal (including thermal resistance) input point, processing thermal resistance or general resistance signal.
High speed pulse input point, processing high speed pulse signal.
Voltage (including thermocouple) input point, processing voltage input or thermocouple signal.
There is also communication, used to exchange data with the upper computer or control the subordinate controller instrument driver
1.2 Difference between digital and analog input modules
According to the difference of field input signal, input module can be divided into switching input module and analog input module.
The function of switching input module is to convert various switching signals into TTL standard signals required by CPU. According to the input power supply type, it can also be DC input module and AC input module. The input signal is converted into TTL (5V) standard signal by photoelectric coupling after voltage division, current limiting and filtering.
sunny He
[Email] sales@xiongbagk.cn
[Mobile] 86-18059884797
[WhatsApp] 86-18059884797
[Skype] sales@xiongbagk.cn
Why Choose Us 3500/92 136188-02 ETHERNET/RS232 MODBUS I/O MODULE BENTLY NEVADA
We are a professional service provider in the field of industrial automation components. We mainly provide PLC module, DCS card, ESD system card, vibration monitoring system card, turbine control system module, gas generator components, we have established a close cooperative relationship with many PLC and DCS product maintenance service providers. The company has established an e-commerce operation model, which reduces the intermediate links for consumers and provides consumers with high-quality products and satisfactory services. The company has a complete logistics supply system. We can buy directly from abroad and supply equipment and spare parts from different countries and manufacturers to solve your problem.
Packing & Shipping
Package Type: New and original factory separately sealed inner box
Delivery time: Prepare delivery inventory;
The goods will be packed according to the international standard.
1. We will deliver the goods within 3 working days after payment.
2. The new and original factory seal the inner box separately
3. We can send it to you by DHL/TNT/UPS/EMS/ fedex.
Please contact us directly and we will deliver the goods according to your requirements. Best quality assurance
4. We promise that all goods we supply are 100% new and original
5. One year warranty (after delivery date).
Payment method: We accept telegraphic transfer
Superiority products 3500/92 136188-02 ETHERNET/RS232 MODBUS I/O MODULE BENTLY NEVADA
Relay module 3500 / 32-01-00 | Temperature monitor 3500/61 (163179-02) |
Keypad module 3500 / 33-01-00 | Temperature monitor 3500/61 (163179-03) |
4-channel Displacement Monitor Module 3500/40 (140734-01, 135489-04) | Temperature monitor 3500 / 61-01-00 (163179-02) |
Vibration module 3500 / 42-01-00 | Instrument frame 3500 / 05-01-01-00-00-00 |
Vibration module 3500 / 42-04-00 | Instrument frame 3500 / 05-01-02-00-00-00 |
Vibration module 3500 / 42-09-00 | Instrument frame 3500 / 05-01-02-00-01 |
Differential / Axial Position Module 3500 / 45-01 | Instrument frame 3500 / 05-02-04-00-00-00 |
Differential / Axial Position Module 3500 / 45-01-00 | Monitoring module 3300 / 50-01-01-00-00 |
Speed module 3500 / 50-01-00 | Monitoring module 3300 / 50-02-01-00-00 |
Bentley 3500 Monitoring Module | Monitoring module 3300 / 52-02-00-00 |