Sale!

1756-PAR2 ControlLogix Redundant Power Supply kit Allen Bradley

1756-PAR2 ControlLogix Redundant Power Supply kit Allen Bradley

Manufacturers :Allen Bradley
Model(s)  :1756-PAR2
Additional Information :ControlLogix Redundant Power Supply kit
Estimated Shipping Size
Dimensions: 263 × 58 × 28mm
Weight:.4.3 kg
Country of Origin: United States of America

 

Categories: , SKU: 1756-PAR2

Description

Overview


Essential details:1756-PAR2 ControlLogix Redundant Power Supply kit Allen Bradley

Products Description

Manufacturer Rockwell Automation
Module Type Redundant Power Supply bundle
Series ControlLogix
Part Number/Catalog No. 1756-PAR2
Brand 1756-PAR2
Assembly components Two (2) 1756-PA75R power supplies,; Two (2) 1756-CPR2 cables; One (1) 1756-PSCA2 Chassis adapter module
1756-PA75R Nom Input Voltage 120/240VAC
1756-PA75R Input Voltage Range 85-264VAC

The Allen-Bradley 1756-PAR2 is a bundled system composed of products that belongs to the ControlLogix product family. The 1756-PAR2 is composed of Two (2) 1756-PA75R power supplies, Two (2) 1756-CPR2 cables and One (1) 1756-PSCA2 Chassis adapter module.

The 1756-PA75R is a redundant power supply use along another power redundant unit. This type of power supply provides failsafe protection and ideally used in critical application that require minimized risks of application downtime. The has an input voltage range of 85-264VAC, 47-63 Hz with nominal input voltage of 120 / 240 VAC along an nominal input frequency of 50/60 Hz. This power supply provides maximum output power of 75 Watts and current capacities of 1.5 @ 1.2 VDC; 4 A @ 3.3 VDC; 13 A @ 5.1 VDC and 2.8 A @ 24VDC.

The 1756-CPR2 is a redundant power supply cable that is used to connect both the power supplies for synchronization and perform internal communication. This cable measures 0.91 m or 3 ft with minimum cable bend radius of 12.7 cm or 5 inches.

The 1756-PSCA2 is a ControlLogix redundant power supply chassis adapter. This component is a passive device, used to consolidate power from both the installed pair of power supplies to the lone power connector that resides on the ControlLogix chassis backplane circuitry.

1756-PAR2

This assembly provides user and control system designers to easily decide on the components of a redundant ControlLogix controller system configuration. It lessens the risk of having an item left-out which may happen when selecting large or complex control systems.

To set up the 1756-PAR2 power supply, attach a standard power supply to the left end of the framework and fasten it directly to the backplane. This unit is built with smart and rugged technology, giving the 1756-PAR2 ControlLogix-XT power supply the ability to withstand extreme temperatures and tough environments. A redundant power supply system provides extra uptime protection for chassis that are used in critical applications; it funnels power through the chassis adapter to the ControlLogix series B chassis backplane. To build a redundant power supply system, a redundant power supply system that offers additional protection for the framework being used in significant applications is required. The power supply directs the power through the framework adaptor to the ControlLogix series B framework backplane. To create a redundant power supply structure, some of the main components that are needed include a pair of bundled systems with one of them containing two 1756-PA75R power supplies, two 1756-CPR2 cables, and one 1756-PSCA2 framework adapter and other one having two 1756-PB75R power supplies, two 1756-CPR2 cables, and one 1756-PSCA2 framework adapter, in addition to a redundant AC power supply, a redundant DC power supply, a redundant power supply cable (with a length of 0.91 meters or 3 feet), a redundant power supply framework adapter, and an annunciator wiring (1) with a maximum length of 10 meters or 32.8 feet.

lf you need to inquire or purchase ,please send the product models to my email or call medirectly .

sunny  He

[Email] sales@xiongbagk.cn

[Mobile] 86-18059884797

[WhatsApp] 86-18059884797

[Skype] sales@xiongbagk.cn

Same day shipment of 1000 parts

My company under the Sales and Marketing Department, technical engineering Department, after-sales service department, the department of comprehensive management. We can help your business with good service.

1. Sales Department 24/7 service. Handles your requests for any PLC DCS products in a timely manner with patience and professionalism.

2. The engineering department ensures that the products have no quality problems. All products will be inspected before shipping.

3. The financial department checks the payment and refund in time.

4. The warehouse department will carefully check the list of goods, carefully pack them, and deliver the goods in time.

5. After-sales Service Department has a full-time after-sales service team, subordinate to the sales department, and users can timely respond to service requests.

Shipping

Superiority products 1756-PAR2 ControlLogix Redundant Power Supply kit Allen Bradley

A-B 1336-L4 TRICONEX 3503E ABB 3BHE037864R0106
A-B 1336F-MCB-SP2G GE IC695CRU320 ABB SDCS-CON-4
YASKAWA JZNC-XRK01D-1 WOODWARD 9907-164 ELAU ISH100/30025/0/0/00/0/00/01/00
ABB COM0032 GE VMIVME-7750 VMIVME-7750-834 350-027750-834 D PROSOFT 3100-MCM
EPICII ALSTOM V4550220-EN ABB 3BHE014185R0001 UUD148AE01 MOOG SM23165DT-DE
BRUEL & KJAER VIBRO VC-920 PILZ 301120 HIMA 4135A
ABB 5SHY4045L0004 LAETUS LLS570-05 A-B 2094-BM01-S/B
ABB 81943A041 GE 469-P1-HI-A20-E KOLLMORGEN S20360-SRS
KONGSBERG RSER200-4 BENTLY 3500/50-01-00-01 ABB AZ20/112112221112E/STD
yokogawa YNT512D A-B 2094-BM02-S/B SST SST-PFB-CLX