Description
Overview
Essential details:LPU100H Input-output module HITACHI
1 Introduction of PLC input/output module
1.1 Difference between digital and analog signals
A digital input/output signal is a switching signal, a 1 or a 0,
Analog signal, there are two, voltage or current signal, is generally the signal transmitted by the transmitter, such as the pressure transmitter to detect the water pipe pressure, it will output an analog signal 4- 20ma or 0-10V signal to PLC, PLC for data processing.
Switching quantity input point (DI), processing switching quantity input signal.
Analog input point (AI), processing analog input signal (0-20 MADc,0-5VDC).
Resistance signal (including thermal resistance) input point, processing thermal resistance or general resistance signal.
High speed pulse input point, processing high speed pulse signal.
Voltage (including thermocouple) input point, processing voltage input or thermocouple signal.
There is also communication, used to exchange data with the upper computer or control the subordinate controller instrument driver
1.2 Difference between digital and analog input modules
According to the difference of field input signal, input module can be divided into switching input module and analog input module.
The function of switching input module is to convert various switching signals into TTL standard signals required by CPU. According to the input power supply type, it can also be DC input module and AC input module. The input signal is converted into TTL (5V) standard signal by photoelectric coupling after voltage division, current limiting and filtering.
The function of analog input module is to convert the continuously changing analog signals such as temperature, flow, current and voltage into a number of digital signals which can be processed by the CPU. The analog input circuit is generally composed of operational amplifier conversion, mode conversion (A/D), photoelectric isolation, etc.
PLC input, output module types: digital input DI, digital output DO, analog input AI, analog output AO.
Digital input and output are generally 24V.
There are two types of analog quantity and four kinds of analog quantity. The two types are voltage type and current type respectively. Voltage type has 0-10V and -10 to 10V. Current type mainly has 4-20MA,0-20MA. Then the module through A/D conversion, the analog quantity converted to +32767~-32768 number, and then the implementation of control.
The function of signal template is to convert various process i/o signals. The input of a variety of signals into digital quantities, easy to plc identification, processing and analysis. The output is converted into analog to various regulating mechanisms to execute, or the output is converted into 2-bit do quantity to control some devices such as start stop, on and off
1.3 Digital input/output module
The switching input module is the processing module of the external control signal or the field detection signal to the PLC CPU. The external signal is generally the button, proximity switch, travel switch and so on.
The output module is the PLC according to the input module into the signal and internal logic programming logic processing, processing results, switching output will be output by the output module high and low level signal, drive the external intermediate relay, contactor, indicator light, solenoid valve and other components, so that the external equipment for the corresponding action
1.4 Functions of the Output module
The function of PLC output module is to amplify the power of the output signal. PLC signal is expressed in level, in order to make it in the process of being read without distortion, it needs to have a certain reserve energy or to have a certain signal power. The function of the output module is actually a power amplifier. The output module is what drives the external load.
Common PLC output device, transistor, thyristor, relay.
PLC input module is used to receive the various parameters of the production process. (start stop)
PLC output module is used to send out the information obtained after the operation of the programmable controller, and through the implementation of the machine to complete all kinds of industrial site control. (The execution results with output) 1. Have good anti-interference ability.
2. It can meet the matching requirements of various signals in industrial sites.
lf you need to inquire or purchase ,please send the product models to my email or call medirectly .
Sales Manager: Manager He
E-mail number:sales@saulcontrol.com
skype/ wechat: +86-18059884797
Mobile phone/wechat: +86-18059884797
QQ:3095989363
Same day shipment of 1000 parts
My company under the Sales and Marketing Department, technical engineering Department, after-sales service department, the department of comprehensive management. We can help your business with good service.
1. Sales Department 24/7 service. Handles your requests for any PLC DCS products in a timely manner with patience and professionalism.
2. The engineering department ensures that the products have no quality problems. All products will be inspected before shipping.
3. The financial department checks the payment and refund in time.
4. The warehouse department will carefully check the list of goods, carefully pack them, and deliver the goods in time.
5. After-sales Service Department has a full-time after-sales service team, subordinate to the sales department, and users can timely respond to service requests.
Superiority products LPU100H Input-output module HITACHI
BENTLY 125680-01 | GE HYDRAN M2 | FOXBORO FCP280 RH924YA |
SIEMENS SIMATIC FIELD PG M4 | ABB UFC760BE142 | FOXBORO RH924UQ |
EPRO PR6423/010-040+CON021 | Alstom MAE99-04 | FOXBORO FCP280 |
EPRO PR6423/010-040+CON021 | Teknic M-3422C-LN-16D | KONGSBERG RMP201-8 |
贝加莱 8MSA3L.R0-30 | BENTLY NEVADA 330850-50-00 | ABB UAD155A0111 3BHE029110R0111 |
WATLOW ANAFAZE CLS208 | YOKOGAWA CP451-50 | A-B 1734-SSIK/C |
GE 469-P5-HI-A20-E SR469-CASE | NI SCXI-1104C | ELAU C200/10/1/1/1/00 |
A-B 2098-DSD-020X/C | EMERSON VE3008 CE3008 KJ2005X1-MQ1 12P6381X042 | ETHERWAN EMC1600 |
ABB CI854A/3BSE030221R1 | ABB PM864AK01 3BSE018161R1 | GE URSHA |
ABB LDSTA-01 | ABB REM620A_F NAMBBABA33E5BNN1XF | REXRTOH R911328500 |
SCHNEIDER 140DAM59000 | ABB AX670 3BSE000566R1 | Lenze MCM09E30-RS0B0, 15884568 |
EATON XV-440-12TSB-1-10 | WOODWARD EGCP-3 8406-113 | A-B 2094-BM02-S/C |
PACIFIC LA23GCKC-1Y | ABB KUC711AE101 3BHB004661R0101 | ABB DSDI452 |
FOXBORO FBM227 P0927AC | ABB KUC720AE01 3BHB003431R0101 3BHB000652R0101 | AB 1756-PH75 |
MTL MTL838B-MBF | ABB KUC720AE101 3BHB003431R0101 3BHB000652R0101 | ULTRA SLIMPAK G448-0002 |