3500/50-01-00-01 Tachometer Module Bently Nevada

3500/50-01-00-01 Tachometer Module Bently Nevada

Manufacturers :Bently Nevada
Model(s)  :3500/50-01-00-01
Additional Information :Tachometer Module
Estimated Shipping Size
Dimensions: 105 x 136 x 19 mm
Weight: 2.2 kg
Country of Origin: United States of America

Categories: , SKU: 3500/50-01-00-01

Description

Overview


Essential details:3500/50-01-00-01 Tachometer Module Bently Nevada

  • Manufacturer : Bently Nevada
  • Product No. : 3500/50M-01-00
  • Product type : Tachometer Module
  • Made in U.S.A
  • I/O module type : 01 = I/O module with internal terminations
  • Agency approval option : 00 = None
  • Shipping weight : 3Kg

3500/50-01-00-01

Sales Manager: Manager He

E-mail number: sales@saulcontrol.com

skypel wechat: +86-18059884797

Mobile phonelwechat: +86-18059884797

QQ:3095989363

 Safety Engineering PC (SENG)
To configure the ProSafe system, the CHS5100 Safety System Generation and Maintenance Package needs to be installed on a PC (IBM PC/AT-compatible computers). The SENG performs engineering and maintenance.
For details on the SENG’s functions, refer to the general specifications (GS 32Q04C10-31E) for the CHS5100 Safety System Generation and Maintenance Package.
 Safety Control Station (SCS)
The SCS offers a safety control functions, the sequence-of-events-recorder (SOER) function, the VP/CS 3000 integration function, and the Modbus connection function which interfaces the SCS with another system.
The SCS consists of a safety control unit (CPU node) and safety node units (I/O node). There are two types of CPU nodes: a standard safety control unit and a wide range temperature safety control unit (equipped with a fan unit).
The CPU node can be connected with the I/O node via the ESB bus. I/O modules can be mounted both on the CPU node and I/O node alike.
Standard Type
SSC10S-S (model name): Safety Control Unit (for V net, Rack Mountable Type, Standard Type)
SSC10D-S (model name): Duplexed Safety Control Unit (for V net, Rack Mountable Type, Standard Type)
Wide Range Temperature Type
SSC10S-F (model name): Safety Control Unit (for V net, Rack Mountable Type, Wide Range Temperature Type)
SSC10D-F (model name): Duplexed Safety Control Unit
(for V net, Rack Mountable Type, Wide Range Temperature Type)
For details, refer to the general specifications “Safety Control Units, Duplexed Safety Control Units (for V net, Rack
Mountable Type)” (GS 32Q06D30-31E).
Basic Software
CFS1100 Safety Control Functions Package
For details of the CFS1100, refer to the general specifications “Safety Control Functions Package”
(GS 32Q03B20-31E).