Description
Overview
Essential details:140734-05A 3500/44M Aeroderivative GT Vibration Monitor
- Four-Channel Monitor
- Designed for Aeroderivative Gas Turbine Applications
- Accepts Input from Two Separate Keyphasor Signals
The GE / Bently Nevada 3500/44M Aeroderivative GT Vibration Monitor is a four-channel monitor designed for Aeroderivative Gas Turbine applications. The Aero GT and TMR Aero GT I/Os interface to velocity transducers through Bently Nevada interface modules 86517 and 86497. The monitor uses the Prox/Velom I/O to interface to GE / Bently Nevada Velomitor sensors and accelerometers. The user can configure the 3500/44M, using the 3500 Rack configuration Software, for any of the following filter options: signal Integration, 1X vibration tracking, or band-pass vibration. The 3500/44M accepts input from two separate Keyphasor signals, allowing each channel pair to use a different tracking filter.
Zona
[Email] sales@saulcontrol.com
[Mobile]Â 86-18150899970
[WhatsApp] 86-18059884797
140734-05A 3500/44M Aeroderivative GT Vibration Monitor
Continuously monitors machinery by comparingmonitored parameters against configured alarmsetpoints to drive alarms
Communicates essential machine information for bothoperations and maintenance personnelThe 3500/44M’s Aero GT l/0 modules interface to Velomitorsensors and accelerometers through Bently Nevada interfacemodules. The monitor uses the Prox/Velom l/O to interface toour .
Using the 3500 Rack Configuration Software, you canconfigure the 3500/44M Aeroderivitive GT Vibration Monitor forthe following filter options:
Signal integration
.1X vibration tracking
Band-pass vibration
The 3500/44M Aeroderivitive GT Vibration Monitor acceptsinput from two separate Keyphasor signals, allowing eachchannel pair to use a different tracking filter.
You can configure multimode channels to have up to eightsets of alarm parameters including alert and dangersetpoints and alarm time delays. Each set may be configuredfor a specific machine mode.
As the machine changes modes, the monitor can switch to aspecific set using contacts on multimode l/o modules orsoftware commands through a communications gateway.