Description
Overview
Essential details:1756-OB16E Allen-Bradley Discrete output module
lf you need to inquire or purchase ,please send the product models to my email or call medirectly .
sunny He
[Email] sales@xiongbagk.cn
[Mobile] 86-18059884797
[WhatsApp] 86-18059884797
[Skype] sales@saulcontrol.com
1756-OB16E Allen-Bradley Discrete output module
Built-in electronic fusing is provided per group. Each output channel exhibits an OFF to ON output delay time of 70 µs nom/1 ms max and On to Off delay time of 360 µs nom/1 ms, max. It draws current from the backplane amounting to 250 mA at 5VDC and 2 mA at 24VDC while the total backplane power requirement is 1.32 Watts and maximum power dissipation is 4.1 W @ 60 °C (140 °F).
The 1756-OB16E module has a voltage category of 12 to 24 Volts DC source voltage, as well as an operating voltage of 10 to 31.2 Volts DC. Its total backplane power is 1.32 Watts and a current draw of 250 milliamps at 5.1 Volts and 2 milliamps at 24 Volts. It also has a maximum of 1 milliamp per point of off-state leakage current and a maximum of 400 mV DC voltage at 1 Amp on-state voltage drop. Its maximum current per point is 1 Amp at 60 degrees Celsius and its maximum current per module is 8 Amps at 60 degrees Celsius. This module has been routine-tested at 1350 Volts AC for 2 seconds and it has a continuous isolation voltage of 250 Volts. Its minimum load current is 3 milliamps per point and its typical surge current is 2 Amps for 10 seconds per point, which is repeatable every 2 seconds at 0 degrees Celsius. The power dissipation of this module is a maximum of 4.1 Watts at 60 degrees Celsius, while its thermal dissipation is 13.98 BTU/hour. It has an output delay time of 70 microseconds nominal/maximum of 1 millisecond from off to on and 360 microseconds nominal/maximum of 1 millisecond from on to off. Its operating temperature is between 0 and 60 degrees Celsius and its non-operating temperature is between -40 and 85 degrees Celsius. This module also allows for the modification of the states in the fault mode and the states in the program mode.