Essential details:2711-K10C1 PanelView Standard Operator Terminals Allen Bradley
Products Description
ATA memory card: | Supported |
Product Type: | PanelView 1000 |
Product Family: | PanelView Standard |
Manufacturer: | Rockwell Automation |
Display Type: | Color active matrix TFT |
Display Area: | 211 x 158 mm (8.3 x 6.2 in.) |
Resolution: | 640 x 480 |
Backlight: | 50,000 hr 1/2 life at 25 °C (77 °F) |
Keypad function keys: | 16 function keys (F1…F16) |
Application memory: | 310KB application runtime; 1008 KB nonvolatile memory (application objects plus text and bitmaps) |
Communication ports: | Data Highway Plus (DH+); RS232 (Printer) |
Input Voltage range: | 85…264V AC, 47…63 Hz |
Accessories: | function key legend inserts; Anti-glare overlays; backlight replacements; Real-time clock replacements; Mounting hardware; Power supply and terminal block; interface modules; |
Printing PanelView terminals equipped with an RS-232 printer port can print:
• triggered messages in a message display.
• triggered states of a multistate indicator.
• alarm messages.
• alarm lists.
Print attributes for objects are defined in the application. Any printer that supports the IBM enhanced character set can be connected to the RS-232 printer port of a PanelView terminal. Alarm List PanelView terminals support an Alarm List queue to store information on triggered alarms. The Alarm List stores a maximum of 100 alarms or as many as the terminal can hold in nonvolatile RAM. The number of alarms stored in the list is configured by using the PanelBuilder32 software.
The Alarm List stores the following data for each alarm:
• Acknowledge indicator
• Alarm date and time
• Acknowledge date and time
• Alarm trigger value
• Alarm text including variables
The Alarm List is cleared:
• when an application is downloaded to the terminal.
• when the terminal is reset or power is cycled.
The Alarm List object may appear on the Alarm Banner or other application screens. The data that displays in the Alarm List is configured using the PanelBuilder32 software.
# Feature Description
1 Nameplate label Provides product information.
2 Sealing gasket Seals the front of the terminal to an enclosure or panel.
3 COMM Status indicator (green) Indicates when communication is occurring.
4 FAULT Status indicator (red) Indicates firmware or hardware faults.
5 Memory card slot Accepts a memory card which stores applications.
6 Power connection terminals Connects to an external 24V DC power source (18…32V DC).
7 DH-485 communication port Connects to an SLC or MicroLogix controller, DH-485 network, or Wallmount Power Supply (Cat. No. 1747-NP1).
8 DH-485 programming connector Connects to a Personal Computer Interface Converter (Cat. No. 1747-PIC) for transferring applications. Also connects to an SLC programmer, such as the Hand-held Terminal (Cat. No. 1747-PT1).
9 RS-232 (DH-485) communication port Connects to the Channel 0 port of an SLC 5/03, SLC 5/04, or SLC 5/05 controller for point-to-point DH-485 communication. Connects to a MicroLogix controller through an AIC+ Link Coupler. Also connects to the RS-232 serial port of a computer for transferring applications.
10 DeviceNet connector Connects to a DeviceNet network.
11 RS-232 (DF1) communication port Connects to a PLC, SLC, or MicroLogix controller with a DF1 port. This port also connects to the RS-232 port of a computer.
12 RS-232 Printer/File transfer port Connects to a printer (K3A10L1 version only). On a DeviceNet terminal, this port also connects to the RS-232 port of a computer for transferring applications.
Why Choose Us 2711-K10C1 PanelView Standard Operator Terminals Allen Bradley
We are a professional service provider in the field of industrial automation components. We mainly provide PLC module, DCS card, ESD system card, vibration monitoring system card, turbine control system module, gas generator components, we have established a close cooperative relationship with many PLC and DCS product maintenance service providers. The company has established an e-commerce operation model, which reduces the intermediate links for consumers and provides consumers with high-quality products and satisfactory services. The company has a complete logistics supply system. We can buy directly from abroad and supply equipment and spare parts from different countries and manufacturers to solve your problem.
Packing & Shipping
Package Type: New and original factory separately sealed inner box
Delivery time: Prepare delivery inventory;
The goods will be packed according to the international standard.
1. We will deliver the goods within 3 working days after payment.
2. The new and original factory seal the inner box separately
3. We can send it to you by DHL/TNT/UPS/EMS/ fedex.
Please contact us directly and we will deliver the goods according to your requirements. Best quality assurance
4. We promise that all goods we supply are 100% new and original
5. One year warranty (after delivery date).
Payment method: We accept telegraphic transfer
Superiority products 2711-K10C1 PanelView Standard Operator Terminals Allen Bradley
A-B | Vibro-meter | NI | HONEYWELL |
A-B 2711P-B12C4D8 | VM600 AMC8 | pxie-8861 | CC-PAIX02 |
A-B 2711-K5A5 | VM600 CPUR | pxie-8135 | CC-TAID01 |
A-B 2711P-RDT15C | VM600 CPUR2 | pxie-8301 | CC-PAON01 |
A-B 2711-B5A2 | VM600 IOC8T | pxie-8880 | HONEYWELL CC-TAON01 |
A-B 2711-K5A2 | VM600 IOCR | pxie-8840 | CC-PDIL01 |
A-B 2711-K5A16L1 | VM600 IOCR2 | pxie-8881 | CC-TDIL01 |
A-B 2711-K10G9 | VM600 IRC4 | pxie-8381 | CC-PCNT01 |
A-B 2711E-T14C6/E | VM600 MPC4SIL | pxie-8360 | CC-TCNT01 |
A-B 2711-K6C9 | VM600 RLC16 | pxie-8821 | CC-PDOB01 |
A-B 2711-K6C15X | VM600 XMC16 | pxie-8510 | CC-TDOB01 |
A-B 2711E-K14C6X/E | VM600 ABE056 | pxie-8398 | CC-PAIM01 |
A-B 2711-K10G8L1 | VM600 ABE042 | pxie-8384 | CC-TAIM01 |
A-B 2711-K5A16 | VM600 IOC4T | pxie-8370 | CC-PCF901 |
A-B 2711P-T6C20D8 | VM600 19 | pxie-8361 | CC-TCF901 |
A-B 2711P-T15C4D8 | VM600 ASPS | pxie-8394 | 51305896-200 |