Use this manual if you are responsible for installing, configuring, andoperating the PanelView Plus Compact terminals.
No special knowledge is required to understand this manual oroperate the terminal. However, you must understand the functionsand operations of the FactoryTalk View ME applications that will runon the terminal. Consult the application designer for this information.
Equipment installers must be familiar with standard panel installationtechniques.
Your terminal is shipped with these items:
Power terminal block
FactoryTalk View ME runtime software preloadedMounting levers or mounting clips (model dependent)e Panel cutout template
eInstallation instructions
Essential details:2711P-T10C4D1 PanelView Plus Compact Terminals
Use this manual if you are responsible for installing, configuring, andoperating the PanelView Plus Compact terminals.
No special knowledge is required to understand this manual oroperate the terminal. However, you must understand the functionsand operations of the FactoryTalk View ME applications that will runon the terminal. Consult the application designer for this information.
Equipment installers must be familiar with standard panel installationtechniques.
Your terminal is shipped with these items:
Power terminal block
FactoryTalk View ME runtime software preloadedMounting levers or mounting clips (model dependent)e Panel cutout template
eInstallation instructions
This chapter covers these topics:
• Product description
• Catalog number explanation
• Software support
• Terminal configurations
• Display modules
• Accessories
Product Overview The PanelView Plus Compact terminals are similar to some PanelView Plus terminal configurations but with limited hardware and software functions. Major differences of the compact terminals include:
• Fixed hardware configuration, without the addition or replacement of modular components.
• Serial and Ethernet communication only.
• Connection to a single logic controller using either RSLinx Enterprise or KEPServer Enterprise software, not both.
• Limited number of displays and alarms in the FactoryTalk View Machine Edition (ME) application and runtime software.
• FactoryTalk ViewPoint software is not supported.
• Primary HMI for CompactLogix controllers.
2711P-T10C22D8S
lf you need to inquire or purchase ,please send the product models to my email or call medirectly .
sunny He
[Email]sales@xiongbagk.cn
[Mobile]Â 86-18059884797
[WhatsApp] 86-18059884797
[Skype]sales@saulcontrol.com
2711P-T10C4D1 PanelView Plus Compact Terminals
Compact Machine Edition applications are restricted to a subset of the functions allowed on the PanelView Plus terminals.
• Maximum of 25 displays
• Maximum of 200 alarm messages
• Maximum screen resolution of 640 x 480 (VGA)
• one connection or shortcut to a single controller using either RSLinx Enterprise 5.20 or KEPServer Enterprise.
• Serial and Ethernet communication only.
If using RSLinx Enterprise, only serial-DF1, serial-DH485 and Ethernet drivers are supported.
The PanelView Plus Compact terminals contain universal serial bus (USB) ports that comply with hazardous location environments. This section details the field-wiring compliance requirements and is provided in accordance with the National Electrical Code, article 500.
Per the National Electrical Code the circuit parameters of nonincendive field wiring apparatus for use in hazardous locations shall be coordinated with the associated nonincendive field wiring apparatus such that their combination remains nonincendive. The PanelView Plus terminal and the USB peripheral device shall be treated in this manner.
The circuit parameters of the PanelView Plus terminal USB port are given in Table 1. The USB peripheral device and its associated cabling shall have circuit parameters with the limits given in Table 2 for them to remain nonincendive when used with the PanelView Plus terminal USB port. If cable capacitance and inductance are not known the following values from ANSI/ISA-RP 12.06.01-2003 may be used:
Ccable = 197 pF/m (60 pF/ft)
Lcable = 0.7 µH/m (0.20 µH/ft)
Nonincendive field wiring must be wired and separated in accordance
with 501.10(B)(3) of the National Electrical Code (NEC) ANSI/NFPA 70 or other local codes as applicable.
This associated nonincendive field wiring apparatus has not been evaluated for use in combination with another associated nonincendive field wiring apparatus.