Essential details:3500/60 Temperature Monitors BENTLY NEVADA
Products Description
The 3500/60 & 61 modules provide six channels of temperature monitoring and accept both Resistance Temperature Detector (RTD) and Thermocouple (TC) temperature inputs. The modules condition these inputs and compare them against user-programmable alarm setpoints. The 3500/60 and 3500/61 provide identical functionality except that the 3500/61 provides recorder outputs for each of its six channels while the 3500/60 does not.
The user programs the modules to perform either RTD or TC temperature measurements using the 3500 Rack Configuration Software. Different I/O modules are available in RTD/TC non-isolated or TC isolated versions. The user can configure the RTD/TC non-isolated version to accept either TC or RTD, or a mixture of TC and RTD inputs. The TC isolated version provides 250 Vdc of channel-to-channel isolation to protect against external interference.
When used in a Triple Modular Redundant (TMR) configuration, temperature monitors must be installed adjacent to each other in groups of three. When used in this configuration, the system employs two types of voting to ensure accurate operation and to avoid single-point failures.
The function of analog input module is to convert the continuously changing analog signals such as temperature, flow, current and voltage into a number of digital signals which can be processed by the CPU. The analog input circuit is generally composed of operational amplifier conversion, mode conversion (A/D), photoelectric isolation, etc.
PLC input, output module types: digital input DI, digital output DO, analog input AI, analog output AO.
Digital input and output are generally 24V.
There are two types of analog quantity and four kinds of analog quantity. The two types are voltage type and current type respectively. Voltage type has 0-10V and -10 to 10V. Current type mainly has 4-20MA,0-20MA. Then the module through A/D conversion, the analog quantity converted to +32767~-32768 number, and then the implementation of control.
The function of signal template is to convert various process i/o signals. The input of a variety of signals into digital quantities, easy to plc identification, processing and analysis. The output is converted into analog to various regulating mechanisms to execute, or the output is converted into 2-bit do quantity to control some devices such as start stop, on and off
1.3 Digital input/output module
The switching input module is the processing module of the external control signal or the field detection signal to the PLC CPU. The external signal is generally the button, proximity switch, travel switch and so on.
The output module is the PLC according to the input module into the signal and internal logic programming logic processing, processing results, switching output will be output by the output module high and low level signal, drive the external intermediate relay, contactor, indicator light, solenoid valve and other components, so that the external equipment for the corresponding action
1.4 Functions of the Output module
The function of PLC output module is to amplify the power of the output signal. PLC signal is expressed in level, in order to make it in the process of being read without distortion, it needs to have a certain reserve energy or to have a certain signal power. The function of the output module is actually a power amplifier. The output module is what drives the external load.
Common PLC output device, transistor, thyristor, relay.
PLC input module is used to receive the various parameters of the production process. (start stop)
PLC output module is used to send out the information obtained after the operation of the programmable controller, and through the implementation of the machine to complete all kinds of industrial site control. (The execution results with output) 1. Have good anti-interference ability.
sunny He
[Email] sales@xiongbagk.cn
[Mobile] 86-18059884797
[WhatsApp] 86-18059884797
[Skype] sales@xiongbagk.cn
Why Choose Us 3500/60 Temperature Monitors BENTLY NEVADA
We are a professional service provider in the field of industrial automation components. We mainly provide PLC module, DCS card, ESD system card, vibration monitoring system card, turbine control system module, gas generator components, we have established a close cooperative relationship with many PLC and DCS product maintenance service providers. The company has established an e-commerce operation model, which reduces the intermediate links for consumers and provides consumers with high-quality products and satisfactory services. The company has a complete logistics supply system. We can buy directly from abroad and supply equipment and spare parts from different countries and manufacturers to solve your problem.
Packing & Shipping
Package Type: New and original factory separately sealed inner box
Delivery time: Prepare delivery inventory;
The goods will be packed according to the international standard.
1. We will deliver the goods within 3 working days after payment.
2. The new and original factory seal the inner box separately
3. We can send it to you by DHL/TNT/UPS/EMS/ fedex.
Please contact us directly and we will deliver the goods according to your requirements. Best quality assurance
4. We promise that all goods we supply are 100% new and original
5. One year warranty (after delivery date).
Payment method: We accept telegraphic transfer
Superiority products 3500/60 Temperature Monitors BENTLY NEVADA
US Bently Bentley 3500 Series Monitoring Module | Vibration module 3500 / 42-04-00 |
4-channel displacement monitor module 3500 / 40-01-00 176449-01 after 125680-01 | Vibration module 3500 / 42-09-00 |
Vibration module 3500 / 42-01-00 176449-02 after the first 128229-01 | Differential / Axial Position Module 3500 / 45-01 |
Power module 3500 / 15-02-02-00 127610-01 Before + 125840-01 | Differential / Axial Position Module 3500 / 45-01-00 |
Frame Interface Module 3500 / 22-01-02-00 138607-01 After 146031-02 | Speed module 3500 / 50-01-00 |
Keypad module 3500 / 25-01-01-00 149369-01 after 125800-01 | Bentley 3500 Monitoring Module |
Relay module 3500 / 32-01-00 125712-01 after 125720-01 | Speed module 3500 / 50-01-00-01 |
Frame interface module 3500 / 20-01-01-00 | Speed module 3500 / 50-01-00-02 |
Frame interface module 3500 / 20-01-02-00 | Speed module 3500 / 50-01-01-00-00 |