Description
Overview
Essential details:362A3342P002 Flame Sensor Cable
Product Description
This document describes the Fireye Turbine Flame Sensor for turbine flame monitoring applications, its installation and setup. The Turbine Flame Sensor responds to Ultraviolet optical energy from the flame (200-400 nanometers) and has a loop powered 4-20mA output representing flame brightness from a very low level. It is not sensitive to visible and IR emissions from hot walls. The Fireye design basis is a total separation of the optical sensing device from the turbine without the need for expensive water or pressurized air cooling systems
At the hot end is a sapphire glass window to protect the lens and fiber optic bundle from extreme pressure and temperature. The fiber optic bundle transmits the UV light to the electronic assembly on the cool end, which amplifies the signal and converts it to a 4-20mA output. The sensor is a loop powered 4-20mA device. The sensor monitoring electronics needs to provide a voltage between 18 and 30 VDC and the sensor will vary the current between 4 and 20mA depending upon the turbine optical signal. Nominal voltage is 24 VDC. With no optical signal from the flame output will be 4mA as a minimum. Because of variation in fuel, sighting, turbine styles, etc. the output level for a FLAME ON is a site decision. Fireye recommends that at least 5 mA be used as a threshold level to detect FLAME ON. The cable has multiple conductors and uses white for +24 VDC and black for the return of the 4-20mA signal.
Product parameter
GE PART # 304T9240P0001
Service FLAME SENSOR
Hazardous area classification Class I, Div 2 – Groups A,B,C & D, (North America). Ex II 3G Ex ec IIC T3 Gc (ATEX/IECEx)
Housing material Stainless Steel 18-8 (304)
Mounting connection 3/4’’ male NPT
Min. operating temperature 32°F/0°C
Min. operating temperature tested -40°F/-40°C
Max. operating temperature hot end 618°F/325°C
Max. operating temperature cool end 284°F/140°C
Humidity 100%
Vibration Per IEC 60068-2-64, Stationary Installation, Category 3
Detection principle Ultraviolet solid state sensor
Sensor Silicon Carbide Diode
Sensitivity 1nW/cm²@310nm
APPLICATION
The Fireye Turbine Sensor is designed to sense flame in extreme high pressure and hot environments such as those found on turbine generators at power generation facilities. The sensor can be used to improve the safety, reliability and performance by replacing obsoleted and outdated technologies. The device has been developed and tested for GE Frames 6F, 7F and 9F.
Superiority products 362A3342P002 Flame Sensor Cable
UFC762AE101 3BHE006412R0101Â Main board module | IC697CMM742-DCÂ Series 90-70 Communications Module |
87199-01Â Stator insulation monitor | FC-TSRO-0824Â Digital Output Field Termination Assembly |
MVME55006E-0161RÂ VMEbus Single-Board Computer | MVC3001-4003AÂ ALSPA MV3000 Delta Controller |
3500/25 149369-01Â Keyphasor module | 6SM57M-3.000Â Synchronous Servomotors |
3500/92 136180-01Â Keyphasor module | 05701-A-0282Â Modbus Interface Module Kit RS422/485 |
1X00416H01Â POWER SUPPLYÂ 24V 300W & 25V 500W OUT DIN-RAIL MOUNT | 3500/91 190782-01Â EGD gateway module |
5X00241G02 Ovation Westinghouse Controller module | 05701-A-0361 System 57 MODBUS Interface |
489-P5-LO-A20Â generator management relay | 3500/65 145988-02Â 16-Channel Temperature Monitor |
TRICONÂ 3805EÂ TRICONEXÂ Analog Output Modules | 3500/65Â 172103-01 16-Channel Temperature Monitor |
5X00226G02 Ovation Westinghouse Controller module | 136188-02 Ethernet/RS485 Modbus I/O Module |
MC-4/11/10/400Â PowerDrive Motion Controller | PCI-6733Â Analog Output Device |
2MLR-CPUH/T  MasterLogic Programmable Logic Controller | 3ASC25H209 DATX110  I/O board control module |
KJ4002X1-BA1Â Left 8 Wide Vertical Carrier | CE4002S1T2B5Â Standard I/O Termination Block |
S72402-NANANAÂ S700Â digital servo drive | CE4005S2B4Â Standard I/O Termination Block |
SCYC55830 58063282AÂ Trigger plate | PCI-4462Â Sound and Vibration Device |
IC697CMM742-DC Ethernet Interface Communications Modules | TU890 3BSC690075R1 compact MTU for the S800 I/O |
PPC322BE1 HIEE300900R1Â Industrial drive function module | KJ4001X1-BE1 12P0818X072 REV:LÂ 8 Wide I/O Carrier with Shield Bar |
VMIVME-3122Â High-Performance 16-Bit Analog-to-Digital Converter (ADC) | KJ2201X1-JA1Â Redundant SLS Terminal Block |