Description
Overview
Essential details:5SHX1960L0004 3BHL000390P0104 HVDC transmission
Products Description
The two components, 5SHX1960L0004 and 3BHL000390P0104, may be related to high voltage direct current (HVDC) systems. HVDC is a type of power system used to transmit large amounts of electricity, usually for long-distance transmission or inter-regional grid interconnection.
In HVDC transmission systems, the 5SHX1960L0004 May be a HVDC circuit breaker or similar device used to control and protect the current in the system. It is able to quickly cut off the current in the event of a fault or the need to disconnect the circuit, preventing the expansion of the fault and ensuring the stable operation of the system.
The 3BHL000390P0104 May be a high-voltage DC transformer or similar device used to convert electrical energy from one voltage level to another. In HVDC transmission system, transformer is one of the essential equipment, which is used to match transmission lines and equipment of different voltage levels to ensure the safe transmission of electric energy.
It is important to note that specific device models and specifications may vary depending on the manufacturer and system requirements.
In addition to converter, converter transformer, filter, arrester, DC circuit breaker and isolation switch, the key components of HVDC transmission system also include the following:
Controller: The controller is the core control part of the HVDC transmission system, responsible for regulating and controlling the DC current transmitted in the system.
Dc cable: Used to transmit direct current power cable, need to have high voltage, high current, low loss and other characteristics.
Grounding system: To ensure the safe running of the system, a sound grounding system is required to connect the devices and pipes in the system to the ground to reduce the impact of lightning strikes and static electricity on the devices.
Relay protection device: used to monitor the operating status of the system, when the system is abnormal, it can automatically cut off the fault part to protect the system safety.
Monitoring system: Real-time monitoring and recording of the operating status of the HVDC transmission system in order to detect and deal with anomalies in a timely manner.
These components play a vital role in HVDC transmission systems to ensure the safe and stable operation of the system.
Superiority products 5SHX1960L0004 3BHL000390P0104 HVDC transmission
ABB | BENTLY | GE | Yokogawa |
CI522A 3BSE018283R1 | 3500/60 163179-01 | UR8FH | Yokogawa PW481-10 |
CI546 3BSE012545R1 | 3500/32 125712-01 | 269PLUS-100P-HI | Yokogawa PW482-50 |
SB510 3BSE000860R1 | 3500/40M 140734-01 | UR8HH | Yokogawa SAI143-H33/PRP |
TC520 3BSE001449R1 | 3500/15 127610-01 | SR469-P5-HI-A20-E | Yokogawa SAI143-S03 |
SR511 3BSE000863R1 | 3500/22M 138607-01 | CB06551 PRD-B040SSIB-63 | Yokogawa SAI533-H33 |
SC520 3BSE003816R1 | 3500/20 125744-02 | CB06551 | Yokogawa SAI533-H33/PRP |
SC510 3BSE003832R1 | 3500/92 136180-01 | VMIVME-7455 | Yokogawa SB401-10 |
RE522 3BSE000743R1 | 1900/65A-01-01-01-00-00 | VMIVME-4140 | Yokogawa SB401-50 |
DSRF197 3BSE019297R1 | 3500/92 136180-01 | VMIVME-2128 | Yokogawa SCP451-53 |
DSAO120A 3BSE018293R1 | 3400/42M | IC695CHS016 | Yokogawa SDV144-S33 |
DSDP170 57160001-ADF | 3500/15 106M1079-01 | E33NCHA-LNN-NS-00 | Yokogawa SDV531-L33 |
TC512V1 3BSE018059R1 | 3500/15-07-00-00 | IC200PWR001D | Yokogawa SDV531-L33/STB4D-00 |
DSDO115A 3BSE018298R1 | 125720-01 | IC698CMX016 | Yokogawa SDV541-S33 |
DSAI130D 3BSE003127R1 | 3500/15 127610-01 | VMIVME-5567-000 | Yokogawa SEC401-51 |
DSDI110AV1 3BSE018295R1 | 128229-01 | VME-7750 | Yokogawa SEC401-11 |
PM904F 3BDH001002R0001 | 3500/53 133388-01 | VME-7750-746001 | Yokogawa SNT401-13 |
TP854 3BSE025349R1 | 3500/42M 176449-02 | IS215UCVEM09A | Yokogawa SNT501-13 |
PM865K01 3BSE031151R1 | 3500/22M-01-01-01 | VMIVME-7698 | Yokogawa SSB401-13 |
TB850 3BSC950193R1 | 3500/22M | IC695CRU320 | Yokogawa STB4D-00 |
SM811K01 32SE018173R1 | 1900/65A | CB06560 PRD-B040SAIB-62 | Yokogawa STB4S-00 |