9905-020 Woodward 2301A Load Sharing and Speed Control Series

9905-020 Woodward 2301A Load Sharing and Speed Control Series

Manufacturers :Woodward
Model(s)  :9905-020
Additional Information :2301A Load Sharing and Speed Control Series
Estimated Shipping Size
Dimensions: 263 × 58 × 28mm
Weight:.4.3 kg
Country of Origin: United States of America

 

Categories: , SKU: 9905-020

Description

Overview


Essential details:9905-020 Woodward 2301A Load Sharing and Speed Control Series

9905-020 Technical Specifications

Dimensions 15.25in W x 7.125in H x 2.5in D
Manufacturer Woodward
Operating Temperature –40 to +85 °C or –40 to +185 °F
Series 2301A
Standards </= 15 W
Weight 3lbs 14oz

Product Description

AX Control offers the 9905-020 control from the 2301A Woodward series. The unit is a forward-acting control, low-voltage model, with an individual actuator and is not offered with a deceleration ramp, the actuator current of this unit is 0-200 mA. When powering this control if the unit falls at an input power of 20-40 Vdc it must be used with a power source that is authorized by the IEC standard with a safety extra-low voltage (SELV). This model requires an operating temperature in the range of -40 to +185 degrees Fahrenheit.

9905-020

lf you need to inquire or purchase ,please send the product models to my email or call medirectly .

sunny  He

[Email] sales@xiongbagk.cn

[Mobile] 86-18059884797

[WhatsApp] 86-18059884797

[Skype] sales@saulcontrol.com

9905-020 Woodward 2301A Load Sharing and Speed Control Series

On this twenty-nine terminal model when it pertains to the minimum fuel contact the control terminals two and three are what control the minimum fuel contact and are needed for this unit to function as needed. The minimum fuel contact is designed to be used for the normal shutdown of the prime mover that the unit is connected to. Under no circumstances should the minimum fuel contact be used as an emergency stop mechanism. 

As the 9905-020 control is a low-voltage model when connecting the shields terminal seventeen must be open for minimum fuel contact, close terminal eighteen to override failed speed signal, and close terminal nineteen for rated speed, if using idle speed ensure that terminal nineteen is open. When using the control under absolutely no circumstances the control should not be mounted on the engine of the prime mover. 

When operating the control the model should not be used anywhere near any other high-current devices as this could cause interference which would affect the quality and performance of the control.