Description
Overview
Essential details:CC-PFB401 Fieldbus Interface Module HONEYWELL
- Manufacturer : Honeywell
- Product No. : CC-PFB401
- Product type : Fieldbus Interface Module
- Module Type : Series C module
- Physical Interface : H1 FOUNDATION Fieldbus
- Number of H1 Networks per FIM : 4
- Configurations : Non-redundant or Redundant (side-by-side)
- Maximum Number of Fieldbus Devices per H1 Network : 16
- Available macrocycle periods : 250, 500 ms; 1, 2, 4, 8, 16, and 32 sec
- Shipping Weight : 3 Kg
I/O Module Functions
• High Level Analog Input /HART Input Module (16pt) – The High Level Analog Input Module supports both high level analog and HART inputs. Analog inputs are typically 4-20mA DC for both traditional and HART devices. HART data can be used for status and configuration. HART data, such as the secondary and tertiary variables, can also be used as process control variables. Two versions are available.
• High Level Analog Input w/o HART (16pt) – The High Level Analog Input Module supports high level analog inputs Analog inputs are typically 4-20mA DC for traditional devices.
• Analog Output/HART Output Module (16pt) – The Analog Output Module supports both standard 4-20mA DC outputs and HART transmitter outputs. Two versions are available.
• Analog Output w/o HART (16pt) – The Analog Output Module supports standard 4-20mA DC outputs.
• Digital Input 24 VDC (32pt) – Digital input sensing for 24V signals. Two versions are available.
• Digital Input High Voltage (32pt) – Digital input sensing for 110 VAC, 220 VAC, 125VDC.
• Digital Output 24 VDC (32 pt) – Current sourcing digital outputs. Outputs are electronically short-circuit protected. Two versions are available.
• Relay Digital Output (32 pt) – Digital output with NO or NC dry contacts. Can be used for low power or high power applications.
• Temperature Multiplexer (64 pt) – Provides thermocouple (TC) and resistance temperature device (RTD) inputs.
The Multiplexer supports up to four, field proven PMIO FTAs.
• Temperature Multiplexer (64 pt) – Provides thermocouple (TC) and resistance temperature device (RTD) inputs.
The Multiplexer supports up to four, field proven PMIO FTAs
• Pulse Input (8pt) – Provide linear counting, PV generation, and Quaduature Input for Custody Transfer
• Universal Input Output (32 pt) – Supports 32 channels of user configurable IO. Choices available – analog input, analog output, digital input, and digital output.
All Series C components feature an innovative design that supports enhanced heat management. This unique look provides a significant reduction in overall size for the equivalent function.
The unique features of Series C I/O include:
• I/O Module and field terminations are combined in the same area. The I/O Module is plugged into the IOTA to eliminate the need for a separate chassis to hold the electronics assemblies.
• Two level “detachable” terminals for landing the field wiring in the enclosure, providing easier plant installation and maintenance.
• Field power is supplied through the IOTA, with no need for extra power supplies and the associated craft wired marshalling.
• Redundancy is available directly on the IOTA without any external cabling or redundancy control devices, by simply adding a second IOM to an IOTA.
• The Series C innovative styling is one of its unique features. This styling includes features to facilitate the effective use of control hardware in a systems environment. These features include:
• Vertical mounting for more effective wiring since most field wiring applications require entry from the top or bottom of the systems cabinet.
• An “information circle” for a quick visual cue to draw the Maintenance Technician’s eye to important status information.
• “Tilted” design for effective heat management within the cabinet enclosure. Since Series C allows for a significant increase in cabinet density, an effective heat management system is critical for high systems availability.
• Input and output circuits are protected from shorts to alleviate the need for in-line fusing, reducing installation and maintenance costs
Superiority products CC-PFB401 Fieldbus Interface Module HONEYWELL
ABB | BENTLY | GE | Yokogawa |
CI522A 3BSE018283R1 | 3500/60 163179-01 | UR8FH | Yokogawa PW481-10 |
CI546 3BSE012545R1 | 3500/32 125712-01 | 269PLUS-100P-HI | Yokogawa PW482-50 |
SB510 3BSE000860R1 | 3500/40M 140734-01 | UR8HH | Yokogawa SAI143-H33/PRP |
TC520 3BSE001449R1 | 3500/15 127610-01 | SR469-P5-HI-A20-E | Yokogawa SAI143-S03 |
SR511 3BSE000863R1 | 3500/22M 138607-01 | CB06551 PRD-B040SSIB-63 | Yokogawa SAI533-H33 |
SC520 3BSE003816R1 | 3500/20 125744-02 | CB06551 | Yokogawa SAI533-H33/PRP |
SC510 3BSE003832R1 | 3500/92 136180-01 | VMIVME-7455 | Yokogawa SB401-10 |
RE522 3BSE000743R1 | 1900/65A-01-01-01-00-00 | VMIVME-4140 | Yokogawa SB401-50 |
DSRF197 3BSE019297R1 | 3500/92 136180-01 | VMIVME-2128 | Yokogawa SCP451-53 |
DSAO120A 3BSE018293R1 | 3400/42M | IC695CHS016 | Yokogawa SDV144-S33 |
DSDP170 57160001-ADF | 3500/15 106M1079-01 | E33NCHA-LNN-NS-00 | Yokogawa SDV531-L33 |
TC512V1 3BSE018059R1 | 3500/15-07-00-00 | IC200PWR001D | Yokogawa SDV531-L33/STB4D-00 |
DSDO115A 3BSE018298R1 | 125720-01 | IC698CMX016 | Yokogawa SDV541-S33 |
DSAI130D 3BSE003127R1 | 3500/15 127610-01 | VMIVME-5567-000 | Yokogawa SEC401-51 |
DSDI110AV1 3BSE018295R1 | 128229-01 | VME-7750 | Yokogawa SEC401-11 |
PM904F 3BDH001002R0001 | 3500/53 133388-01 | VME-7750-746001 | Yokogawa SNT401-13 |
TP854 3BSE025349R1 | 3500/42M 176449-02 | IS215UCVEM09A | Yokogawa SNT501-13 |
PM865K01 3BSE031151R1 | 3500/22M-01-01-01 | VMIVME-7698 | Yokogawa SSB401-13 |
TB850 3BSC950193R1 | 3500/22M | IC695CRU320 | Yokogawa STB4D-00 |
SM811K01 32SE018173R1 | 1900/65A | CB06560 PRD-B040SAIB-62 | Yokogawa STB4S-00 |