Description
Overview
Essential details:DCF506-0140-51 DCS Thyristor Power Converters for DC drive systems
lf you need to inquire or purchase ,please send the product models to my email or call medirectly .
sunny He
[Email] sales@xiongbagk.cn
[Mobile]Â 86-18059884797
[WhatsApp] 86-18059884797
[Skype] sales@saulcontrol.com
DCF506-0140-51 DCS Thyristor Power Converters for DC drive systems
a.The power sections of sizes Ci and C2 aremonitored by an electrically isolated PTC ther-mistor detector, which is installed on the likewiseelectrically isolated heat sink near the thyristors.The resistance change proportional to thetemperature is acquired and evaluated in theunit’s software. lf the temperature rises above acertain value predefined by the unit codinginvolved, then first an alarm will be outputted.and if the temperature continues to rise -anerror message. This means that changes in therated cooling conditions, such as cooling airvolume and temperature, the fan itself, overloaddue to an excessively high load current, etc. aredetected.
b.The size-A5 power section is likewise monitoredby an electrically isolated PTC thermistor detector, which is installed on the non-isolated heatsink in an isolated configuration. Evaluation ofthe resistance and the protection effect corre-spond to those mentioned for point (a.) above.
c. The size A6 and A7 power section is not directlymonitored by an electrically isolated PTC ther-mistor detector. For this size, the same thermis-tor detector is used as for (a.) and (b.) above, but it is here not mounted on a heat sink but close tothe fan air outlet. The detector thus measures thepower section’s radiated heat and any changesin the cooling air temperature and volume. Sincethe cooling air volume can only be detectedindirectly, a differential-pressure switch has beenadditionally fitted at the unit’s housing, alwayslocated close to the power terminals.The resistance change proportional to thetemperature is acquired and evaluated in theunit’s software. lf the temperature rises above theparameterized value, then first an alam will beoutputted, and -if the temperature continues torise -an error message. The value to be set forthis parameter must not be more than 10 de-grees above the permissible ambient tempera-ture.
The differential-pressure switch compares thepressure inside the unit with the nomal atmos-pheric pressure. lf the fan has been switched onand the unit door closed (and no unit casingshave been removed), the pressure switch willsignal “Cooling conditions ok”, which means thedrive may be enabled. There is no need to setany specific differential pressure (recommenda-tion: centre setting).