Sale!

HE693THM665 Isolated Thermocouple Module 

The Isolated Thermocouple Input Modules allow thermocouple temperature sensors to be directly connected to the PC without external signal processing (transducers, transmitters, etc.). All analog and digital processing of the thermocouple signal is performed by the module. These backplane-isolated (or bus-isolated) modules report temperature values to the PLC I/O table in increments of 0.5°C, 0.5°F, 0.1°C, or 0.1°F respectively. The module features six thermocouple channels whose temperature values are reported to 6 %AI input registers. Each channel can be individually configured for a specific type of sensor wire. There are 6 %I alarm bits and one setpoint alarm for each channel.

Categories: ,

Description

Overview


Essential details:HE693THM665 Isolated Thermocouple Module 

The Isolated Thermocouple Input Modules allow thermocouple temperature sensors to be directly connected to the PC without external signal processing (transducers, transmitters, etc.). All analog and digital processing of the thermocouple signal is performed by the module. These backplane-isolated (or bus-isolated) modules report temperature values to the PLC I/O table in increments of 0.5°C, 0.5°F, 0.1°C, or 0.1°F respectively. The module features six thermocouple channels whose temperature values are reported to 6 %AI input registers. Each channel can be individually configured for a specific type of sensor wire. There are 6 %I alarm bits and one setpoint alarm for each channel. (The HE693THM667 has 12 alarm bits and two setpoints per channel.) Alarm setpoints are configured for each channel using 6 %AQ registers. An available feature on the isolated thermocouples is the use of external AD592 cold junction compensation. This allows cold junction compensation to be accomplished in a remote isothermal terminal strip with standard copper wire run from the remote terminal strip to the module.
There are four versions of the Horner APG Isolated Thermocouple Input Module: HE693THM668, HE693THM667, HE693THM666 and HE693THM665. The HE693THM668 is a six-channel module with +/-1500V AC isolation to the PLC backplane and +/-250V AC isolation channel-to-channel. The HE693THM667 is similar to the HE693THM668 except that the HE693THM667 has 2 setpoints per channel. The HE693THM666 is equivalent to the HE693THM668 with the addition of a 60Hz notch filter.
The HE693THM665 is also equivalent to the HE693THM668 with addition of a 50Hz notch filter. The purpose of these filters is to eliminate noise generated by power lines in the United States (60Hz) and Europe (50 Hz).

HE693DAC410

lf you need to inquire or purchase ,please send the product models to my email or call medirectly .

sunny  He

[Email] sales@xiongbagk.cn

[Mobile] 86-18059884797

[WhatsApp] 86-18059884797

[Skype] sales@saulcontrol.com

HE693THM665 Isolated Thermocouple Module

The THM668 supports remote cold junction compensation. This allows the thermocouple sensors to be connected to a remote terminal strip. Standard shielded copper wiring can then be run between the remote terminal strip and the module terminal strip. The remote terminal strip must be “isothermal” in nature. It should be constructed with a built-in AD592 temperature sensor and even thermal characteristics. The module can detect the presence of an external AD592 temperature sensor and perform cold junction compensation based upon the remote sensor instead of the module’s on-board
AD592. Horner APG offers an isothermal remote terminal strip (HE693ISOBLK). See Section 2.3 for more information on the HE693ISOBLK.

The Horner APG HE693ISOBLK is a remote terminal strip which can be used in conjunction with the HE693THM668/667/666/665. It features an isothermal terminal strip, with integrated AD592 temperature sensor. Connections between the remote terminal strip and the isolated thermocouple module are accomplished through a DB25 connector. Pinouts for the ISOBLK screw terminals, DB25 connector, and the isolated thermocouple terminal strip are shown as follows. Cabling constructed by the customer connects the ISOBLOCK’s DB25 female connector and the THM668/667/666/665 module’s terminal strip.

The effect of digital filtering (set with Byte 2) on module response to a temperature change. The THM665 and THM666 are approximately 4 times slower due to the effects of the filtering. (% Temp Change Completed vs. Time).

The effect of digital filtering (set with Byte 2) on module response to a temperature change. The THM665 and THM666 are approximately 4 times slower due to the effects of the filtering. (% Temp Change Completed vs. Time).