Sale!

IC660BBD110  115VAC 16-Circuit Discrete Input Block

The 115VAC Discrete Input Block (lC66*BBD110) is an intelligent,configurable module that provides an interface to 115VAC discreteinput sensors. The block has sixteen 115VAC circuits – two banks ofeight circuits each.
Typical inputs to this block are contact closures from switches,pushbuttons, or limit switches. The block can be used with both 2-wire and 3-wire proximity switch inputs. Control power for the blockcomes from the power line that supplies the inputs. No separateblock power supply is needed.

Categories: ,

Description

Overview


Essential details:IC660BBD110  115VAC 16-Circuit Discrete Input Block

Compatibility

The 115VAC Discrete Input Block (lC66*BBD110) is an intelligent,configurable module that provides an interface to 115VAC discreteinput sensors. The block has sixteen 115VAC circuits – two banks ofeight circuits each.
Typical inputs to this block are contact closures from switches,pushbuttons, or limit switches. The block can be used with both 2-wire and 3-wire proximity switch inputs. Control power for the blockcomes from the power line that supplies the inputs. No separateblock power supply is needed.

Features

Block features include:
 Selectable thresholds
 Advanced diagnostics

Software Configurable Features

The 16 Circuit 115 VAC Input Block provides configurable detection of Open Wire and Shorted Wire faults. Selectable thresholds extend the use of Open Wire and/or Shorted Wire diagnostics to circuits with many types of input devices and sensors.
 There are separate On/Off thresholds for each group of eight inputs. On/Off thresholds are configurable from 25% to 85% of the incoming line voltage, allowing the use of a wide variety of input sensors.
 Optional Open Wire detection can be selected for individual inputs. The Open/Off threshold can also be configured at 25% to 85% of the incoming line voltage. Separate Open/Off thresholds can be selected for each group of eight inputs.
 Optional Short Circuit detection at 10% and 90% of the incoming line voltage can also be selected for individual inputs.
For most applications, the default thresholds and recommended resistor values are not changed.
Fault reporting can also be enabled or disabled circuit-by circuit.

IC660BBD101

lf you need to inquire or purchase ,please send the product models to my email or call medirectly .

sunny  He

[Email] sales@xiongbagk.cn

[Mobile] 86-18059884797

[WhatsApp] 86-18059884797

[Skype] sales@saulcontrol.com

IC660BBD110  115VAC 16-Circuit Discrete Input Block

Compatibility

This block is fully compatible with Hand-held Monitor modelIC66*HHM501 only.
Installation Instructions
Carefully inspect all shipping containers for damage. lf anyequipment is damaged, notify the delivery service immediately. Savethe damaged shipping container for inspection by the deliveryservice. After unpacking the equipment, record all serial numbers.Save the shipping containers and packing material in case it isnecessary to transport or ship any part of the system.
Block MountingGenius lO blocks are considered “open equipment” and thereforemust be installed within a protective enclosure. They should belocated in an area that is clean and free of alrbome contaminants.There should be adequate cooling airflow.The block can be mounted right side up, or upside down. Leave atleast 2 inches of space between blocks. Mount the block by drillingtwo screw or bolt holes for 8-32 hardware. Position the block so thatthe notches in the upper and lower flanges line up with the mountingholes. Mount the block using 8-32 screws. Use star washers toprovide ground integrity.
GroundingThe block’s mounting screws must not be used as the only meansof grounding the block. Connect the green ground screw on theblock to a reliable ground system using a short wire lead, minimumsize AWG #12 (avg 3.3mmin cross-section).