Essential details:IC694ALG233 PACSystems RX3i Analog Current Input Module
DESCRIPTION
IC694ALG233 is a PACSystems RX3i Analog Current Input Module with 16 single-ended input channels. Each input is configurable using configuration software for three input ranges: 4 to 20 mA, 0 to 20 mA, and 4 to 20 mA Enhanced.
High and low alarm limits are offered on the three ranges. For the 4 to 20 mA Enhanced range, a low alarm limit can be initiated to detect input current from 4 mA to 0 mA; this provides open-wire fault detection in 4 to 20 mA Enhanced applications. Additionally, IC694ALG233 reports module status and status of the external power supply to the CPU via its assigned program reference addresses. IC694ALG233 must be installed in an I/O slot with a serial connector in an RX3i system.
The IC694ALG233 module is software-configurable, and there are no module jumpers to set. Open-circuit detection for all inputs is available in 4 to 20 mA Enhanced Range. Configurable scaling and offsets and fault reporting are other useful features. The module supports diagnostic point fault contacts in the logic program and supports upgrades for firmware. Positive and negative rate of change alarms as well as module serial number/revision/date code display are included. The module also supports hot insertion/removal.
Module status is easily determined by emitting LEDs as follows. ON means OK, and the module is correctly configured. OFF equates to no backplane power, or it’s possible that the software not running. If the LED emits continuous fast blinking, configuration data issues are present. Slow blinking followed by OFF indicates a failed power-up diagnostics issue or a code execution error has been encountered. The USER SUPPLY LED determines that the external 24 VDC supply is appropriate.
Product parameter
Module Type: | Analog Current Input |
Number of Inputs: | 16 single-ended |
Internal Power: | +5V: 120 mA |
Number of Slots: | 1 (single slot) |
Current Range: | 0-20 mA, 4-20 mA, 4-20 mA (Enhanced) |
Backplane Support: | No backplane restrictions |
APPLICATION
There are 16 channels total on the IC694ALG233 input module and each channel can be configured with the following input ranges: 0 to 20 milliamps, 4 to 20 milliamps enhanced, and 4 to 20 milliamps normal. High and low alarm limits can also be configured through software. For the 4 to 20 milliamps enhanced current range, a low alarm limit can be configured for the detection of an input current between 4 and 20 milliamps. This feature can be used to provide open-wire detection in 4 to 20 milliamps enhanced current rated applications. The IC694ALG233 input module also reports the module status and external power supply status to the system CPU by using the assigned program reference addresses. The IC694ALG233 input module can be installed in I/O slots that come with a serial connector. The IC694ALG233 input module supports hot removal and insertion. The firmware on the IC694ALG233 input module can be upgraded to enable new features.
lf you need to inquire or purchase ,please send the product models to my email or call medirectly .
Same day shipment of 1000 parts
My company under the Sales and Marketing Department, technical engineering Department, after-sales service department, the department of comprehensive management. We can help your business with good service.
1. Sales Department 24/7 service. Handles your requests for any PLC DCS products in a timely manner with patience and professionalism.
2. The engineering department ensures that the products have no quality problems. All products will be inspected before shipping.
3. The financial department checks the payment and refund in time.
4. The warehouse department will carefully check the list of goods, carefully pack them, and deliver the goods in time.
5. After-sales Service Department has a full-time after-sales service team, subordinate to the sales department, and users can timely respond to service requests.
Superiority products IC694ALG233 PACSystems RX3i Analog Current Input Module
PFCL201CE  ABB  Pressure sensor controller | KJ2231X1-EA1 4-20 mA Series 2 Card EMERSON |
MTL BPHM64 Eaton Safety grid base plate | 330106-0530-10-02-05 Proximity Probes Bently Nevada |
1794-IF4IXT Allen Bradley Flex I/O 1794 series input module | Max-4/11/03/032/99/1/1/00 SERVO MOTOR ELAU |
1734-IM4 Allen Bradley POINT I/O 4 Point Digital Input Module | 330104-00-08-90-02-05  Proximity Probes Bently Nevada |
1769-ECR Allen-Bradley Right end cover (ECR) module used together | D201139L Metso RT node PC AP31 D200137 personality module |
136188-02 Bently Nevada Ethernet /RS232 Modbus I/O module | D201376 Metso RT node PC AP31 D200137 personality module |
AI02J ABB  Analog input module | IS220PRTDH1A 336A4940CSP6 Resistance Temperature Device (RTD) Input Module GE |
DSSA165 ABB Ac power module | IS220PSCAH1A 336A4940CSP9  Mark VI component GE |
PXIe-1073 NI PXI Chassis | IS220PDIAH1BE 336A5026ADP4 Resistance Temperature Device (RTD) Input Module GE |
F860-CAÂ HONEYWELLÂ Series C “fieldbus interface module | IS420ESWBH3AXÂ GEÂ Analog I/O modules |
DSSA165 ABBÂ Ac power module | 516TX 336A4940DNP516TXÂ GEÂ 516TX-A Industrial Ethernet Switch |
125840-02 Bently Power module | 128277-01 Future Expansion Faceplate Bently Nevada |
125680-01 BENTLYÂ Displacement detection module | A413139Â PC BOARD CIRCUIT BOARD MODULE ASSEMBLYÂ METSO |
147663-01 BENTLY Communication analog output module | D201471 Metso RT node PC AP31 D200137Â personality module |
125800-01 Bently Nevada Key phase input/output module | A413188Â PC BOARD CIRCUIT BOARD MODULE ASSEMBLYÂ METSO |
140471-01 Bently Nevada Developed I/O module with internal terminal | A413331 PC BOARD CIRCUIT BOARD MODULE ASSEMBLYÂ METSO |
3500/22M 138607-01 Bently Detector module | D201466 Metso RT node PC AP31 D200137 personality module |
3500/94 145988-01 BENTLY Display module | 85UVF1A-1QD Fireye Integrated Flame Scanner with Internal Flame Relay |
3500/42M 176449-02 bently nevada Shaft vibration module | 516TX 336A4940DNP516TXÂ GEÂ A microprocessor device |
3500/92 136180-01 bently nevada Communication gateway module | 516TX-336A4940DNP516TX GE microcontroller |
136180-01 Bently Nevada Communication gateway module | 2MLR-CPUHT HONEYWELLÂ CPU HT bus function |
3500/92-03-01-00 Bently Nevada 3500/92-03-01-00 | 177313-01-01 BENTLY NEVATA Vibration monitoring module |
7264Â ABB The four-channel SSI interface module features automatic | PXIE-6556Â NIÂ Automatic industrial control module |
MDB-8EÂ SARTORIUS Load cell | PFCL201CEÂ Â ABBÂ Â Pressure sensor controller |
3500/15 127610-01 Bently Nevada Digital input module | MTL BPHM64 Eaton Safety grid base plate |