Sale!

IRDH275  Digital ground fault monitor / ground detector

This device meets or exceeds the requirements of NEC 250.21(B) and CEC 10-106(2) for ground detectors in ungrounded AC systems, as well as the upcoming 2014 requirement of NEC 250.167(A) for ungrounded DC systems.

Categories: ,

Description

概观


Essential details:IRDH275  Digital ground fault monitor / ground detector

This device meets or exceeds the requirements of NEC 250.21(B) and CEC 10-106(2) for ground detectors in ungrounded AC systems, as well as the upcoming 2014 requirement of NEC 250.167(A) for ungrounded DC systems.
The IRDH275 monitors for ground faults in ungrounded single-phase AC, three-phase AC, and DC systems by monitoring the system’s insulation resistance. It may be connected to systems of up to 793 VAC / 650 VDC. Voltage coupler accessories extend this range. The AMP Plus measuring principle utilized by the IRDH275 meets the requirements of modern power systems, including pure DC systems, systems with rectifiers, and systems with variable frequency drives (VFDs). In systems with high leakage capacitances, the IRDH275 automatically adapts itself to ensure an accurate reading.
The IRDH275 features a digital display showing the system’s insulation resistance’in real-time. All settings are changed via the device’s built-in menu. The IRDH275 utilizes an external supply voltage for power, which allows deenergized systems to also be monitored.
For a panel mounted version, please refer to the IRDH375.

IRDH275B-435 

lf you need to inquire or purchase ,please send the product models to my email or call medirectly .

sunny  He

[Email] sales@saulcontrol.com

[Mobile] 86-18059884797

[WhatsApp] 86-18059884797

[Skype] sales@saulcontrol.com

IRDH275  Digital ground fault monitor / ground detector

When the insulation resistance from system to ground falls below the set response value, the alarm relays switch and the alarm LEDs activate. Two separately adjustable alarmcontacts can be set to a prewarning and main warning alarm. The measured value is indicated on the LCD display or an externally connectable measuring instrument. A latching setting (“fault memory”) allows the device to reset automatically or require a manual reset. An external and internal test/reset can be activated remotely or on the device. A comprehensive INFO menu displays additional information such as the system’s leakage capacitance.
The IRDH275 continuously monitors the equipment ground connection to ensure proper operation. The device’s easy-to-use onboard menu manages all settings via the detailed LCD screen.

• History memory with real-time clock to store up to 300 timestamped event records
• Galvanically isolated RS-485 interface (BMS protocol) for data exchange with other Bender devices and communication systems
• Standby contacts and RS-485 communication for operating multiple ground fault detectors in systems tied together with tiebreakers or interlocks
• Galvanically isolated analog output, 0(4 ) – 20 mA

IS420ESWBH3AX  GE  Analog I/O modules 147663-01 BENTLY Communication analog output module
516TX 336A4940DNP516TX  GE  516TX-A Industrial Ethernet Switch 125800-01 Bently Nevada Key phase input/output module
128277-01  Future Expansion Faceplate  Bently Nevada 140471-01 Bently Nevada Developed I/O module with internal terminal
A413139  PC BOARD CIRCUIT BOARD MODULE ASSEMBLY  METSO 3500/22M 138607-01 Bently  Detector module
D201471 Metso RT node PC AP31 D200137  personality module 3500/94 145988-01 BENTLY Display module
A413188  PC BOARD CIRCUIT BOARD MODULE ASSEMBLY  METSO 3500/42M 176449-02 bently nevada Shaft vibration module
A413331 PC BOARD CIRCUIT BOARD MODULE ASSEMBLY  METSO 3500/92 136180-01 bently nevada  Communication gateway module
D201466 Metso RT node PC AP31 D200137  personality module 136180-01 Bently Nevada Communication gateway module
85UVF1A-1QD  Fireye  Integrated Flame Scanner with Internal Flame Relay 3500/92-03-01-00 Bently Nevada 3500/92-03-01-00
516TX 336A4940DNP516TX  GE  A microprocessor device 7264  ABB The four-channel SSI interface module features automatic
516TX-336A4940DNP516TX GE  microcontroller MDB-8E  SARTORIUS Load cell
2MLR-CPUHT HONEYWELL  CPU HT bus function 3500/15 127610-01 Bently Nevada  Digital input module
177313-01-01 BENTLY NEVATA Vibration monitoring module 3500/50 133388-02 BENTLY NEVADA  Tachometer monitoring module 4 channels
PXIE-6556  NI  Automatic industrial control module 3500/40-03-00 176449-01 BENTLY NEVADA  Expansion axial position module
PFCL201CE   ABB   Pressure sensor controller 3500/15 Plastic panel  BENTLY NEVADA   Ac and DC power supplies
MTL BPHM64  Eaton  Safety grid base plate X20CP1586 B&R The core product of B&R’s I/O system line
1794-IF4IXT  Allen Bradley  Flex I/O 1794 series input module IC698PSA350 GE  High capacity power module
1734-IM4 Allen Bradley POINT I/O 4 Point Digital Input Module VMIVME 3215-000 GE  Computer module
1769-ECR Allen-Bradley  Right end cover (ECR) module used together 201TI GE  Microprocessor-based electrical transmitter
136188-02 Bently Nevada  Ethernet /RS232 Modbus I/O module 3500/05-01-02-00-00-01 BENTLY  System rack
AI02J  ABB   Analog input module PM865K02 ABB  controller
DSSA165 ABB  Ac power module 3500/22-01-01-00 138607-01 BENTLY  Transient data interface before and after the size card module
PXIe-1073  NI  PXI Chassis IS420UCSBH4A GE Controller module manufactured by General Electric
F860-CA  HONEYWELL  Series C “fieldbus interface module D201376 METSO Analog input module
DSSA165 ABB  Ac power module D201376 METSO Analog input module
125840-02 Bently Power module IS420UCSBH4A GE Controller module manufactured