Description
Overview
Essential details:KJ1501X1-BC1 System Dual DC Power Supply EMERSON
Products Description
Field power supplied to this device, either at the field terminal or as bussed field power through the carrier, must be removed before removing or connecting the device.
This unit may be removed or inserted while system power is energized under the following conditions: (Note Only one unit at a time may be removed with system power energized.)
• When used with KJ1501X1-BC1 System Dual DC/DC Power Supply operating on 24 VDC or 12 VDC input power. The primary circuit wiring inductance for input power must be less than 23 uH, or a certified supply with an open circuit voltage, Ui of 12.6 VDC and an Lo of less than 23 uH (including wire inductance).
• Non sparking field circuits MUST be deenergized before removing and inserting this product.
A rotary keying system ensures compatibility between I/O cards and terminal blocks after installation is complete. The terminal block must have the keys set for the I/O card with which it is to be used.
Modular design allows flexible installation. A T- type DIN rail is all you need to mount the power/controller carrier into place. The I/O interface carrier plugs on to the power/controller carrier. Simply plug your I/O terminal blocks into the carrier.
The DeltaV system’s modular design approach allows you to add I/O carriers as you need them. Allows you to expand online. Additional 8-wide carriers may be added online as desired. Carrier extenders give you the flexibility to install I/O carriers in multiple rows with 1,2, 3 or 4 carriers per row.
Integrated power distribution. Controller and I/O interface power distribution is integrated into the carriers to reduce and simplify power and grounding. Carriers also have integrated shield ground bar to isolate and drain field noise away from system power.
The I/O interface carrier plugs on to the power/controller carrier. The power/controller carrier supplies the system power and communications between the I/O interfaces and the controller. The controller processes the I/O interface information. An additional power/controller carrier is required for use with redundant controllers.
Mount your interface carrier on a T-type DIN rail. The I/O interface carrier includes the connections for the bulk 24 V DC field instrument power, I/O interfaces, and terminal blocks. Each I/O interface carrier is equipped with a connector that allows an additional I/O interface carrier to be plugged on to it. Up to 64 I/O interfaces on eight 8-wide I/O interface carriers are supported by a single I/O subsystem. For the horizontal-mount solution, 1-wide local bus extenders allow you to continue the I/O bus on a different row of carriers. There are two types of 8-wide I/O interface carriers available. They both have connectors for field power on the top of the carrier. The original carrier connects each set of field power terminals to two I/O cards, and the other option have individual field power per card slot and is ideal if separate field power is required for redundant I/O cards.
lf you need to inquire or purchase ,please send the product models to my email or call medirectly .
sunny He
[Email] sales@xiongbagk.cn
[Mobile] 86-18059884797
[WhatsApp] 86-18059884797
[Skype] sales@xiongbagk.cn
Same day shipment of 1000 parts
My company under the Sales and Marketing Department, technical engineering Department, after-sales service department, the department of comprehensive management. We can help your business with good service.
1. Sales Department 24/7 service. Handles your requests for any PLC DCS products in a timely manner with patience and professionalism.
2. The engineering department ensures that the products have no quality problems. All products will be inspected before shipping.
3. The financial department checks the payment and refund in time.
4. The warehouse department will carefully check the list of goods, carefully pack them, and deliver the goods in time.
5. After-sales Service Department has a full-time after-sales service team, subordinate to the sales department, and users can timely respond to service requests.
Superiority products KJ1501X1-BC1 System Dual DC Power Supply EMERSON
Emerson’s Ovation relay outputs 12 X 5A26458G02 | Emerson’s Ovation HART analog input module 5X00058G01 |
Emerson’s Ovation Relay outputs 12 user supplied relays 5A26458G03 | Emerson’s Ovation HART analog input module 5X00059G01 |
Emerson Ovation Relay Output logic module 1C31219G01 | Emerson Ovation High Speed HART analog input EMOD 5X00106G01 |
Emerson’s Ovation Relay Output Base – High power 1C31222G01 | Emerson Ovation High Speed HART analog input PMOD 5X00109G01 |
Emerson Ovation Relay Output Base – Low power 1C31223G01 | Emerson Ovation 4-20mA Analog Input Module High Speed 5X00070G01 |
Emerson’s Ovation HART analog output module 5X00062G01 | Emerson Ovation 1V Analog Input module High Speed 5X00070G02 |
Emerson Ovation HART analog Output module 5X00063G01 | Emerson Ovation 10V Analog Input module High Speed 5X00070G03 |
Emerson’s Ovation HART High performance analog Output 1X00188H01 | Emerson Ovation 0-1 mA Analog Input Module High Speed 5X00070G04 |
Emerson’s Ovation HART High performance analog output Module 5X00170G01 | Emerson’s Ovation 8-channel RTD input EMOD 5X00119G01 |
Emerson’s Ovation HART High performance analog Output Module 5X00167G01 | Emerson’s Ovation 8-channel RTD input PMOD 5X00121G01 |
Emerson’s Ovation Sony 12 data tape 5X00082H12 | Emerson Ovation 4-20mA analog Enter EMOD 1C31224G01 |
Emerson hurrah for the Control board | Emerson Ovation 4-20mA analog input PMOD 1C31227G01 |
Emerson’s Ovation Data Server Domain controller station 5X00354G01 | Emerson’s Ovation 1V simulation input EMOD 1C31224G02 |