The purpose of this manual is fo provide the user with information onthe installation,connection and configuration of the MTL831Banalogue mutliplexer transmitler.
Cautionary Note: In common with all other elecirical apparatusinstalled in hazardous areas, this apparatus must only be installedoperated and maintained by competent personnel. Such personnelshall have undergone iraining, which included insiruction on thevarious types of protection and installation practices, the relevantrules and regulations, and on the general principles of areaclassification. Appropriate refresher training shall be given on aregular basis. [See clause 4.2 of EN 60079-17].This instruction manual supplements the reguiremenis of nationallyaccepled codes of practice, for example, lEC/EN 60079.14 inEurope and the National Electrical Code, combined withANSl/ISA-RP 12.12 in the USA. All installations should comply withthe relevant seclions of these codes.

Categories: ,

Description

Overview


Essential details:MTL831B IS Analogue Multiplexer Transmitter

ABOUT THIS MANUAL
The purpose of this manual is fo provide the user with information onthe installation,connection and configuration of the MTL831Banalogue mutliplexer transmitler.
Cautionary Note: In common with all other elecirical apparatusinstalled in hazardous areas, this apparatus must only be installedoperated and maintained by competent personnel. Such personnelshall have undergone iraining, which included insiruction on thevarious types of protection and installation practices, the relevantrules and regulations, and on the general principles of areaclassification. Appropriate refresher training shall be given on aregular basis. [See clause 4.2 of EN 60079-17].This instruction manual supplements the reguiremenis of nationallyaccepled codes of practice, for example, lEC/EN 60079.14 inEurope and the National Electrical Code, combined withANSl/ISA-RP 12.12 in the USA. All installations should comply withthe relevant seclions of these codes.
In addition, particular industries or end users may have specificrequiremenis relaling to the safety of their installations, and theserequirements should also be met”.
Related documents1.1
This manual does NOT cover the connection or configuration of theMTL838B-MBF receiver. For details of this item consult.
*INM838B-MBF
Addifional applicafion information is available in:
AN9010.
1.2Product description
The MTl83lB analgue iransmitter can transfer a number ofhazardous area input signals to the safe area down a data highwayconsisling of a single twisted pair cable. lt is intrinsically safe and cantherefore be mounted in Zone 0 hazardous areas or Class l, Divisionlhazardous locafions.
The MTL831B can monitor up to 16 inputs from THC or millivol!
sources or up lo 15 inputs from 2,3 or 4-wire RTDs.
Two (i.e. dual redundant) data highway outputs are provided that cancarry both signal and power over dislances up to 3km, depending onthe application, the cable and the (noise) environment . see Section4.4. The highway cables can be simple twisled-wire pairs or pairs olwire within an lS mulfi-core cable.

MTL831B

lf you need to inquire or purchase ,please send the product models to my email or call medirectly .

sunny  He

[Email] sales@xiongbagk.cn

[Mobile] 86-18059884797

[WhatsApp] 86-18059884797

[Skype] sales@saulcontrol.com

MTL831B IS Analogue Multiplexer Transmitter

At the other end of the data highway, MTL838B-MBF receivers areused to translate the information transmitled from the MTl83 1B. TheMTL838B-MBF provides a Modbus” serial dala oulput representafionof the inputs together with stalus informalion.
When the MTl83lB transmitler is mounted in the hazardous areaeach data highway must be protected by an MTL3052 digital isolatormounted in the safe area.
GETTING STARTED
Installation of the MTl831B multiplexer iransmitter is divided intothree main topics.
Mechanical Installation . how io mount the TL831B andhow it may be filted inlo our enclosure.
Electrical Connections.the sensor and highwayconnections.lf units are installed in our enclosures, it delails anyspecial wiring arrangements.
Configuraton -the address and input mode selection by thesetling of internal switches.Note: A new user might find it helpful to set up the system, or asimple version of it,in an indoor test area to gain familiarisationbefore undertaking installation on site.
MECHANICAL INSTALLATION
3.1
Locafion
The Mll831B can be installed in either safe or hazardous areas(including Zone O or Division l) depending upon the requiremenls ofthe application.
3.2Mounting options
The unit can be mounted on T-section DlN-rail or onto a fat surfaceEaton has a range of enclosures.ENC8,ENC8-SS,ENC83 oENC83-5S to provide suitable lP67 protection if the transmitter islocated in an exposed areg.
3.2.1Mounting on Tsection DiN-rail (Figure 1Hook the side opposite the central mounting clip onlo shandard 35mmDN46277 T-section rail and push downwards unlil the unit clicks intopiace.
To remove, ease the central clip below the base of the unit outwardswith a screwdriver, and unhook the clips on the other side.