PFCL201C 50kN 3BSE006699D0005 Pressductor PillowBlock Load Cells
The measuring principle of the sensor is based on the Pressductors technology and the fact thatthe permeability of a magnetic material changes under mechanical stress.
The sensor is a membrane machined in the load cel. Primary and secondary windings are woundthrough four holes in the load cell so that they cross at right angles.
The primary winding is supplied with an alternating current which creates a magnetic field aroundthe primary winding. Since the two windings are at right angles to each other, there will be no mag.netic field around the secondary winding, as long as there is no load on the sensor.
When the sensor is subjected to a mechanical force in the direction of measurement, the propaga.tion of the magnetic field changes so that it surrounds the secondary winding, inducing an alternating voltage in that winding.
The control unit converts this alternating voltage into a DC voltage proportional to the appliedforce. lf the measurement force changes direction, the sensor signal changes also polarity.
When choosing a mounting arrangement it is important to remember to position the load cell in adirection that gives sufficient measuring force (F,) to achieve the highest possible accuracy.The load cell has no particular correct orientation; it is positioned in the orientation best suited forthe application, bearing in mind the positions of the screw holes. The load cell can also be installedwith the roll suspended under the load cel.
The load cell has the same sensitivity in both tension and compression, so the load cell can beinstalled in the easiest manner.